D/B UFC Construction of NBCO Multipurpose Facility N6274223R6623

Naval Base Camilo Osias, Sta. Ana, Cagayan, Philippines Part 3

b. Perform dewatering as required to remove water from excavations.


c. Provide temporary cover plates to all excavation pits to ensure construction areas are flush with
surrounding grade. Load bearing capacity of each cover shall not be less than surrounding
surface. The cover plate shall be sized to prevent collapsed edges of the excavation pit, and shall
be secured to prevent slipping.
d. Foundation shall be designed to suit subsurface conditions, and shall be capable of transmitting
all building loads to the ground.
e. Design and construction shall comply with Part 4, A10 Foundations.
f. Foundations shall be reinforced concrete construction.
g. Maximum gross allowable soil bearing pressure shall be determined by the Contractor’s (KTR)
geotechnical data.
h. The new floors area must be protected against infiltration of moisture from the sub-grade. The
Contractor shall prepare the sub-grade surface
rface and install a suitable DPM (damp proof
membrane) material. The material shall be permanent moisture barrier that shall not disintegrate
over time and shall act as an underlay preventing loss of moisture and infiltration of moisture
from the existing sub-grade.

A1010 STANDARD FOUNDATIONS

Provide reinforced concrete foundations.

A1030 GROUND FLOOR SLABS


a. As determined by the Designer of Record, provide soil supported concrete slab on ground
with moisture barrier. Floor slab-on-grade shall resist minimum compressive concrete
strength of 27.6 MPa (4,000 psi).
b. Floor thickness shall be determined by a combination of live load, dead load, strength of
concrete, and subgrade conditions. Minimum floor thickness is 150-mm thick.
B SHELL
B10 SUPERSTRUCTURE
a. Construct a 1-story building.
b. Contractor shall verify the structural and foundation design for compliance with applicable
codes and wind and seismic design requirements.
c. Building superstructure shall be reinforced concrete frame system, with column, beam and
slab structural members.
d. Calculations and drawings shall clearly show a clear load path to the foundation and how
each structural member will transfer loads from member to member.
e. Loading combination shall incorporate dead, super-dead, live, wind, and earthquake loads,
please refer to the codes for the minimum design loads, except for the wind speed the
minimum design load is 196 km/h (122mph); Exposure Category C; Risk Category: IV;
Earthquake Loads: Mapped seismic acceleration parameters: Ss: 167; S1: 79.
f. Building’s concrete slab minimum thickness shall be 120 mm (bare concrete, before finishes)
except for slab-on-grade the minimum thickness is 100 mm.
g. Structural roof beam shall be constructed in integral part with building’s structural member.
No roof structure is allowed to sit or ties directly to concrete masonry unit bricks.

B1010 FLOOR CONSTRUCTION

The floor shall be steel reinforced concrete complying with Applicable codes in Section 2.1.
Reinforced concrete slabs shall have minimum compressive strength of 27.6 MPa (4,000 psi).

Page 15 of 27 v4 dated 11/12/18