Professional Documents
Culture Documents
Aa 036142 012
Aa 036142 012
NOTES:
LIST OF MATERIAL
1. ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED.
102
SHEILD WIRE OR OPGW
DWG. ISSUE REQ'D.
SHEILD WIRE OR OPGW
AMS # DESCRIPTION 2. POLES SHALL BE PRE-DRILLED WITH 20MM DIA HOLES
CODE. UNIT QTY.
AT LOCATIONS SPECIFIED IN THIS DRAWING.
1 1000390097 EA 4 BOLT: STEEL MACHINE; ƒ" x 14 IN. LONG. 3. ALL PRE-DRILLED HOLES SHALL BE PROVIDED WITH
OF
CAPS OR PLUGS (DURABLE PLASTIC OR COMPOSITE
2 1000391426 EA 3 CLEVIS, INSULATOR: CLEVIS- BALL. MATERIALS).
CONSENT
3 1000393239 EA 3 CLEVIS: SOCKET EYE, 21MM, 15.9MM . 4. EARTHING NUT SHALL BE PROVIDED WITH BOLT AND
898
1 7 8 2 3 10 12 WASHER.
4 45026 74313-0001 EA 8 CROSSARM; STEEL 4"x6"x8FT LONG TUBE WITH BRACE.
4
(TYPICAL FOR 3) 5. POLE SHALL BE PERMANENTLY MARKED WITH MANU-
5 1000233194 EA 10 WASHER: SPRING; FOR ƒ" BOLT. FACTURERS NAME YEAR OF MANUFACTURE LEGNTH
TTEN
AND ULTIMATE LOAD RATING.
6 1000233149 EA 10 WASHER: ROUND: FLAT; FOR ƒ" BOLT.
6. REFER TO SAES-P-107, TABLE-1 FOR CONDUCTOR
WRI
7 1000391984 EA 6 EYE: NUT ƒ" SZ. GALV.
& JUMPER CLEARANCES OR INSTALL SIDE INSULATORS.
THE
8 10003872254 EA 12 INSULATOR: PORCELAIN, SUSPENSION. 7. CROSSARM LENGTH FOR 34.5KVSHALL BE 10FT LONG.
THOUT
ACCORDINGLY FOR 34.5KV SYSTEM.
10 1000390607 EA 6 CLAMP; DEADEND ALUMINIUM FOR 2/0 AWG TO 266.8 MCM STRANDED.
9. INSTALL FUSE CUTOUTS IF NEW LINE IS MORE THAN
WI
11 1000374679 EA 6 CONNECTOR: ELECT. TERM. LUG 4/0 AWG.
5 SPAN OR 450M. ON THE FIRST POLE.
NG
12 1000389836 EA 16 BOLT: 5/8" x6" LONG WITH WASHER & NUTS. 10. STAND-OFF INSULATORS SHALL BE USED FOR
DRAWI
34.5KV FUSE CUT-OUTS.
1857
S
THI
15 1000390126 EA 12 BOLT: DOUBLE ARMING, 3/4" DIA; 22" LONG. AS PER 14-SAMSS-403.
FROM
MAY BE USED. REFER TO SAES-P-107 FOR DETAILS.
NED
18 1000392957 ST 5 ARMOR ROD FOR 4/0 AWG.
OBTAI
19 1000522061 EA 3 LINK FUSE; 10A.
BE
21 08-513-446 EA 2 TAG; BRASS TAG
PART,SHALL
22 15-008-858 MT 18 WIRE: BARE COPPER SOFT DRAWN 50MM Sq. (#1/0 AWG)
22
1348
N
I
FULL,OR
REFERENCE DRAWINGS
5 6
13 14 15 16 18
N
I ON
REPRODUCTI
*
1348
SAES-P-107, TABLE-1
(OVER HEAD CONDUCTOR AND CLEARANCE REQUIREMENTS)
SEE
SEE NOTE 6
NOTE - 10
LAYOUT DISCRIPTION 34.5KV 13.8KV
SAUDIARAMCO.NO
17
11 CONDUCTOR SPACING
HORIZONTAL CONFIGURATION 1.0M 0.76M
OF
SEE NOTE - 6
PROPERTY
50MM
GREEN BAND
9
7000
SOLE
SIDE ELEVATION
THE
ARE
NAME PLATE
N
HEREI
21
POLE GROUNDING
NED
SCALE: NONE
CONTAI
REVISION VALIDATION
GROUND LEVEL
THIS REVISION NO. 00 IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
ON
765200-0915-001
NFORMATI
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
RM JAB RM JAB
09/01/15 09/01/15 09/01/15 09/01/15
I
00 09/01/15 NEW STANDARD FOR STEEL POLE
THE
JOB ORDER/EWO NO.
THIS REVISION IS NOT TO BE USED FOR
765200 CONSTRUCTION UNTIL CERTIFIED AND DATED
AND
DRAWING TYPE
NG
13.8KV -34.5KV OVERHEAD POWERLINE
DRAWI
STANDARD DRAWING
BEARING PLATE
FRONT ELEVATION STD. DWG. SAUDI ARABIA
S
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.
THI
990 P AA-036142 012 00
Saudi Aramco 2615 ENG. (05/05)