國 立 臺 北 科 技 大 學

電子學實習報告

實習 14:CommonCollector

組別:第 9 組
主筆:賴東彥(110310110)
組員:林郁傑(110310135)

中華民國一一一年十二月二十三日

(A) Pspice simulation:


(a) Always-in-active

`
V CE Q=6. 496−0.4276=6.0684 V , I CQ =3.504 mA

−33.46241 m
A v= =−3.346241
10 m

直流分析:
β=16 0
10=1.14 k ( β+ 1 ) I B +147.61 k I B +0.687 ⇒ I B=28.12(μA)
I CQ =4.4992(mA )
V CEQ =10−4.4992 m×1.14 k=4.870912(V )

交流分析:
25 m
r π= =889.047
28.12 μ
假設i i=1 A
v ¿=889 i b +140 ×161 i b
v ¿=147.61 k ( 1−i b ) +(0.5 k )(1−ib −160 i b)
23.429 k i b=147.61 k −147.61 k i b +0.5 k −0.5 k i b−80 k i b
252 .034 k i b=148.11k

1
14CommonCollector
⇒ i b=0.5876
R¿ =v¿ =23.429 k i b=13.767 ( k Ω )
v out =−46.801 k
v out −46.801 k
A v= = =−3.3993
v¿ 13.767
i L −v o /1 k
Ai= = =46.801
ii 1

(b) Common collector

V CEQ =10−6.644=3.356 V , I CQ =9.681 mA

9.8 9660 m
A v= =0.989660
10 m
直流分析:
β=16 0
10=20.732 k I B + 0.64+161 k I B ⇒ I B=0.0515(m A)
I CQ =8.24( mA )
V CEQ =10−8.24 m× 0.68 k =4.39 68(V )
2
14CommonCollector
交流分析:
25 m
r π= =485.437
0.0515 m
假設i i=1 A
v ¿=485.437 i b+ 340× 161i b
v ¿=20. 732 k ( 1−i b )
48 5.437 i b +54740 i b=20 .732 k−20.732k i b
759 57.437 i b=20.732 k
⇒ i b=0.27294
R¿ =v¿ =20.732 k (1−0.27294)=15.0734 ( k Ω )
v out =0.34 k × 161× 0.27294=14.941 k
v out 14. 941 k
A v= = =0.9912
v ¿ 15.0734 k
i L −v o /1 k
Ai= = =−14.941
ii 1

(B) 實驗步驟:
(1) 選擇自己組別號碼算出來的電阻值。
(2) 選擇型號 3904 的 NPN 電晶體來做為此次實驗用的元件。
(3) 在麵包板上連接如下圖所示的電路,並測量此電晶體的 β 跟 V BE 的值。

(4) 把下圖所示的電晶體電路於麵包板上連接出來,量測結果表需要的數值。

3
14CommonCollector
(5) 把下圖所示的電晶體電路於麵包板上連接出來,量測結果表需要的數值。

(6) 計算誤差百分比並且填入結果表中。

(C) 計算:
(a) Always-in-active
(1) 分析
直流分析:
β=16 0
10=1.14 k ( β+ 1 ) I B +147.61 k I B +0.687 ⇒ I B=28.12(μA)
I CQ =4.4992(mA )
V CEQ =10−4.4992 m×1.14 k=4.870912(V )

交流分析:
25 m
r π= =889.047
28.12 μ
假設i i=1 A
v ¿=889 i b +140 ×161 i b
v ¿=147.61 k ( 1−i b ) +(0.5 k )(1−ib −160 i b)
23.429 k i b=147.61 k −147.61 k i b +0.5 k −0.5 k i b−80 k i b
252.034 k i b =148.11k
⇒ i b=0.5876
R¿ =v¿ =23.429 k i b=13.767 ( k Ω )
v out =−46.801k
v out −46.801 k
A v= = =−3.3993
v¿ 13.767
i L −v o /1 k
Ai= = =46.801
ii 1

4
14CommonCollector
(2) 模擬
I CQ =3.504 mA
V CEQ =6.496−0.4276=6.0684 V
−33.46241 m
A v= =−3.34624 1
10 m
(3) 實驗
I CQ = 4 .156 ( mA )
V CEQ =5.8963 ( V )
AV =v out /v s =−3.23
(b) Common collector
(1) 分析
β=16 0
10=20.732 k I B + 0.64+161 k I B ⇒ I B=0.0515(mA )
I CQ =8.24( mA )
V CEQ =10−8.24 m× 0.68 k =4.3968(V )

交流分析:
25 m
r π= =485.437
0.0515 m
假設i i=1 A
v ¿=485.437 i b+ 340× 161i b
v ¿=20.732 k ( 1−i b )
485.437 i b +54740 i b=20.732 k −20.732 k i b
75957.437 i b=20.732 k
⇒ i b=0.27294
R¿ =v¿ =20.732 k (1−0.27294)=15.0734 ( k Ω )
v out =0.34 k × 161× 0.27294=14.941 k
v out 14.941 k
A v= = =0.9912
v ¿ 15.0734 k
i L −v o /1 k
Ai= = =−14.941
ii 1
(2) 模擬
I CQ =9.681 ( mA )
V CEQ =3.356 ( V )
AV =v out /v s =0.989660 3
(3) 實驗
I CQ =9. 632 ( mA )
V CEQ =4. 085 ( V )
5
14CommonCollector
AV =v out /v s =¿ 9 7 0 m/990 m=0.9798 ¿
(c) 誤差百分比
Always-in-active:
(1) 模擬
I CQ ( mA ) 的誤差百分比=2 2.12 %
V CEQ ( V ) 的誤差百分比=2 4.58 %
AV 的誤差百分比=1.56 %
(2) 實驗
I CQ ( mA ) 的誤差百分比=7 .63 %
V CEQ ( V ) 的誤差百分比=2 1.05 %
AV 的誤差百分比=4 .98 %
Common collector:
(1) 模擬
I CQ ( mA ) 的誤差百分比=1 7.49 %
V CEQ ( V ) 的誤差百分比=2 3.67 %
AV 的誤差百分比=0.16 %
(2) 實驗
I CQ ( mA ) 的誤差百分比=1 6.89 %
V CEQ ( V ) 的誤差百分比=7 .09 %
AV 的誤差百分比=1.15 %

6
14CommonCollector
(D) 結果:
組別號碼:9
使用的元件:
RG =1 40 Ω (Always-in-active)
R B=147.61 k Ω (Always-in-active)
R=R G 2=R L =680 Ω(Common collector)
R B=29 k Ω (Common collector)
β Standard =160

結果表:
Simulation Experiment
Item Name Analysis
Value Error(%) Value Error(%)

(a)
1 X
waveform

(a)
2 4.4992 3.504 22.12 4.156 7.63
I CQ ( mA )
(a)
3 4.870912 6.0684 24.58 5.8963 21.05
V CEQ ( V )
(a)
4 -3.3993 -3.346241 1.56 -3.23 4.98
AV

(b)
5 X
waveform

(b)
6 8.24 9.681 17.49 9.632 16.89
I CQ ( mA )
(b)
7 4.3968 3.356 23.67 4.085 7.09
V CEQ ( V )
(b)
8 0.9912 0.9896603 0.16 0.9798 1.15
AV

7
14CommonCollector
(E) 心得:
這次的實驗室做 Common collector 電路,在聽完教授上完課之後,便開始與組員一
起動手進行實作,我負責接電路,而組員負責分析電路,因為我們要確保做出來的電路 ,
測量的數值是否會跟理論值差太多,如果差太多就可能代表著我們的電路有出問題,或
是有雜訊干擾等等,待我們排除這些問題後,測得的數值與分析的數值誤差百分比盡可
能不要誤差太大。像我們這次實作的過程中就有發現我們 Common collector 的電壓增益
與算的數值差很多,我就開始檢查電路是否有接錯,而組員則是去檢查他的計算過程有
沒有錯誤,最後幸好有找到問題所在,是計算的失誤而導致數值不一樣,重算之後,就
與我們量測的數值相當接近了。這次的做的 Always-in-active 和 Common collector 兩個
電路並沒有很困難,利用 R B可變電阻,將V CE 調至 0.5 V ,看此時的 R B是多少歐姆,固定
R B,去用示波器看輸入輸出的波形,並測量教授要求的數值,即可完成本次的實習課程。