The document discusses wiring techniques for programmable logic controllers (PLCs). It explains that PLC input modules receive discrete input signals from field devices that are either 0 or 24 volts, representing logic 0 or 1. PLC output modules send discrete output signals of 0 or 24 volts to control field devices. The document also describes sinking and sourcing configurations for PLC input and output modules and cards.
The document discusses wiring techniques for programmable logic controllers (PLCs). It explains that PLC input modules receive discrete input signals from field devices that are either 0 or 24 volts, representing logic 0 or 1. PLC output modules send discrete output signals of 0 or 24 volts to control field devices. The document also describes sinking and sourcing configurations for PLC input and output modules and cards.
The document discusses wiring techniques for programmable logic controllers (PLCs). It explains that PLC input modules receive discrete input signals from field devices that are either 0 or 24 volts, representing logic 0 or 1. PLC output modules send discrete output signals of 0 or 24 volts to control field devices. The document also describes sinking and sourcing configurations for PLC input and output modules and cards.
The document discusses wiring techniques for programmable logic controllers (PLCs). It explains that PLC input modules receive discrete input signals from field devices that are either 0 or 24 volts, representing logic 0 or 1. PLC output modules send discrete output signals of 0 or 24 volts to control field devices. The document also describes sinking and sourcing configurations for PLC input and output modules and cards.
CENTRE, GULSHAN E IQBAL, KARACHI www.plctrainingcentre.com +923330274741 ENGINEER SHAHRUKH SHAIKH PLC WIRING TECHNIQUES • PLC INPUT OUTPUT MODULE
ENGINEERING TECHNICAL TRAINING
CENTRE +92 3330274741 PLC WIRING TECHNIQUES • DISCRETE INPUT OR DIGITAL INPUT • IT WILL BE 0 VOLTS OR 24 VOLTS • FOR PLC IT WILL BE LOGIC “O” OR LOGIC “1” • MEANS “OFF” OR “ON” • TEMPERATURE SWITCHES, PRESSURE SWTICHES, LEVEL SWITCHES ETC….
ENGINEERING TECHNICAL TRAINING
CENTRE +92 3330274741 PLC WIRING TECHNIQUES • DISCRETE OUTPUT OR DIGITAL OUTPUT • IT WILL BE 0 VOLTS OR 24 VOLTS • FOR PLC IT WILL BE LOGIC “O” OR LOGIC “1” • MEANS “OFF” OR “ON” • RELAY, CONTACTORS, SOLENOID VALVE, COILS ETC…. ENGINEERING TECHNICAL TRAINING CENTRE +92 3330274741 PLC WIRING TECHNIQUES • PLC INPUT MODULE/ PLC INPUT CARD • 16 DIGITAL INPUT CARD • IT WILL RECEIVE SIGNALS FROM FIELD SWITCHES • DIGITAL INPUT CARD IS USE TO COLLECT SIGNALS/ INFORMATION FROM FIELD SWITCHES • EITHER IT WILL RECEIVE 0 VOLTS OR 24 VOLTS • 0 VOLTS MEANS “NO SIGNAL” OR “OFF” • 24 VOLTS MEANS “SIGNAL” OR “ON” ENGINEERING TECHNICAL TRAINING CENTRE +92 3330274741 PLC WIRING TECHNIQUES • SINKING INPUT PLC CARD • NEED TO CONNECT NEGATIVE OR COMMON TO PLC AND INPUT CHANNEL WE COMPLETE THE POWER LOOP BT PROVIDING POSITIVE OR 24V
ENGINEERING TECHNICAL TRAINING
CENTRE +92 3330274741 PLC WIRING TECHNIQUES • SOURCING INPUT PLC CARD • NEED TO CONNECT POSITIVE OR 24V TO PLC AND INPUT CHANNEL WE COMPLETE THE POWER LOOP THROUGH NEGATIVE.
ENGINEERING TECHNICAL TRAINING
CENTRE +92 3330274741 PLC WIRING TECHNIQUES • PLC OUTPUT MODULE/ PLC OUTPUT CARD • 16 DIGITAL OUTPUT CARD • IT WILL SEND SIGNALS TO FIELD DEVICES • DIGITAL OUTPUT CARD IS USE TO SEND SIGNALS/ INFORMATION TO FIELD DEVICES • EITHER IT WILL SEND COMMAND 0 VOLTS OR 24 VOLTS • 0 VOLTS MEANS “NO SIGNAL” OR “OFF” • 24 VOLTS MEANS “SIGNAL” OR “ON”
ENGINEERING TECHNICAL TRAINING
CENTRE +92 3330274741 PLC WIRING TECHNIQUES • SOURCING OUTPUT MODULE • POWER SUPPLY POSITIVE 24 VOLTS WILL BE CONNECTED TO PLC • SO THE OUTPUT CHANNEL WILL PROVIDE 24 VOLTS TO DEVICE AND THE NEGATIVE OF POWER SUPPLY WILL BE DIRECTLY CONNECTED TO FIELD DEVICE.
ENGINEERING TECHNICAL TRAINING
CENTRE +92 3330274741 PLC WIRING TECHNIQUES • SINKING OUTPUT MODULE • POWER SUPPLY NEGATIVE OR COMMON WILL BE CONNECTED TO PLC. • SO THE OUTPUT CHANNEL WILL SHARE COMMON OR NEGATIVE TO DEVICE AND THE POSITIVE OF POWER SUPPLY WILL BE DIRECTLY CONNECTED TO FIELD DEVICE.
ENGINEERING TECHNICAL TRAINING
CENTRE +92 3330274741 THANKS FOR PARTICIPATION
ETTC ENGINEERING TECHNICAL TRAINING CENTRE WWW.PLCTRAININGCENTRE.COM +92 333 0274741