Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Total No. of Questions : 4] SEAT No.

8
23
PA-1 [Total No. of Pages : 2

ic-
[5931]-1

tat
S.E. (Civil Engineering)

0s
0:4
201001 : BUILDING TECHNOLOGY AND ARCHITECTURAL

02 91
PLANNING

0:4
0
(2019 Pattern) (Semester - I)

31
6/0 13
0
1/2
Time : 1 Hour] [Max. Marks : 30
.23 GP

Instructions to the candidates :


1) Attempt Q1 or Q2 and Q3 or Q4.
E
81

8
2) Figures to the right indicate full marks.
C

23
3) Draw neat figures wherever necessary.

ic-
16

4) Assume necessary data.

tat
8.2

5) Use of scientific calculator is allowed.

0s
.24

0:4
91
49

Q1) a) Write short note on : Need of Construction Automation and its Benefits.
0:4
30

[5]
31

b) Differentiate between : [5]


01
02
1/2

i) English bond vs Flemish bond


GP
6/0

ii) Stone masonry vs brick masonry


CE
81

8
c) Explain casting procedure for reinforced concrete columns. [5]

23
.23

ic-
OR
16

tat
Q2) a) Write short note on : Slip form work [5]
8.2

0s

b) Differentiate between : [5]


.24

0:4
91

i) Formwork vs scaffolding
49

0:4
30

ii) Underpinning vs formwork


31
01

c) List out types of building as per National Building. [5]


02
1/2
GP
6/0

Q3) a) Illustrate shortly following Architectural principals. [5]


CE
81

i) Unity
.23

ii) Accentuation
16

iii) Mass composition


8.2
.24

P.T.O.
49
b) Distinguish between : [5]

8
23
i) Aspect vs Prospect

ic-
tat
ii) Grouping vs Circulation

0s
c) On a plot size 45m × 55m, the shorter side is facing the main road. The

0:4
side margins are as follows : Front margin - 5.5m, rear and side margins

02 91
0:4
are all 2m; Earlier FSI allowed was 1.5. However, only ground storied

0
31
construction after leaving the margins was built by the owner. Now, as
6/0 13
per the new norms, FSI allowed is increased to 2.5. If 2 more storeys are
0
proposed by the owner. Determine the additional area to be built on each
1/2
.23 GP

floor. [5]
E

OR
81

8
C

23
Q4) a) Illustrate shortly following Architectural principals. [5]

ic-
16

tat
i) Proportion
8.2

0s
ii) Contrast
.24

0:4
91
49

iii) Rhythm
0:4
30
31

b) Distinguish between : [5]


01
02

i) Building Planning principals and Building bye laws


1/2
GP

ii) Built up area vs carpet area


6/0
CE

A plot owner proposed G + 1 construction with 240 m2 construction on


81

c)

8
23
each floor, on a plot of size is 20m × 30m. If all margins are 2m and
.23

F.S.I. allowed - 1. Find : i) Ground coverage ii) FSI Consumed


ic-
16

tat
iii) Whether plan will be sanctioned or not. iv) If not, by how much
8.2

0s

amount the proposed area will be required to be minimize by the owner,


.24

0:4

so that the proposal will be sanctioned by the authorities. [5]


91
49

0:4


30
31
01
02
1/2
GP
6/0
CE
81
.23
16
8.2
.24

[5931]-1 2
49

You might also like