Professional Documents
Culture Documents
Weld Work Volume Calculation
Weld Work Volume Calculation
Weld Work Volume Calculation
Geometrical groove shape, and Approximate calculation of totally weld metal QtyGeometrical size of Reinforcement
Wall Thickness mm 13.49 a
Bevel Angle deg. 30 b
Root Face mm 1.5 c
Root Gap mm 3 d
Pipe Diameter inch (mm) 4 101.6
Welded area mm2 123
Inc. Reinforcement mm2 163
Necessary Deposit Metal gram 408
Deposit efficiency % 83 SMAW 60-75%, GMAW 90-95%, GTAW 95-98%
Necessary Electrode gram 492
c
a
b
d
c
a
b
d