Sr. Chapter SSR Item Reference No.

Description of the item Additional Unit Completed Labour


No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

SSR 2022-23 :- Reinforced Cement Concrete


836 Reinforced 25.11 BDF 3 Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite Bd.F.3 Page One One Cubic Metre 7104 2110
Cement Concrete /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, Number 298 and
grillage and footings of R.C.C. columns and steel stanchions etc. including bailing B.7, Page One
out water, Steel centering formwork, laying/pumping cover blocks, compaction and Number38
curing roughening the surface if special finish is to be provided (Excluding reinforcement
and structural steel) etc. complete, with fully automatic micro processor based PLC with
SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc.
complete. With fine aggregate (Crushed sand VSI Grade)

837 Reinforced 25.13 BDF 3 Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / Bd.F.3 Page One One Cubic Metre 7287 2110
Cement Concrete granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip Number 298 and
foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including B.7, Page One
bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, Number38
compaction and curing roughening the surface if special finish is to be provided
(Excluding reinforcement and structural steel) etc. complete, with fully automatic micro
processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch
mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

838 Reinforced 25.15 BDF 3 Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / Bd.F.3 Page One One Cubic Metre 7471 2110
Cement Concrete granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip Number 298 and
foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as B.7, Page One
per detailed designs and drawing or as directed including Steel centering formwork, Number38
cover blocks laying/pumping, compaction finishing the formed surfaces with cement
mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or
roughening if special finish is to be provided and curing etc. complete. (Excluding
reinforcement and structural steel). with fully automatic micro processor based PLC
with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan
mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

839 Reinforced 25.17 BDF 3 Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap / Bd.F.3 Page One One Cubic Metre 7562 2110
Cement Concrete granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, Number 298 and
grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed B.7, Page One
designs and drawing or as directed including Steel centering, formwork, cover Number38
blocks, laying/pumping, compaction finishing the formed surfaces with cement
mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or
roughening if special finish is to be provided and curing etc. complete,(Excluding
reinforcement and structural steel).with fully automatic micro processor based PLC
with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan
mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

840 Reinforced 25.19 BDF 3 Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / Bd.F.3 Page One One Cubic Metre 7801 2110
Cement Concrete granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, Number 298 and
grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed B.7, Page One
designs and drawing or as directed including steel centering, formwork, cover Number38
blocks, laying/pumping, compaction finishing the formed surfaces with cement
mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or
roughening if special finish is to be provided and curing etc. complete. (Excluding
reinforcement and structural steel).with fully automatic micro processor based PLC
with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan
mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

841 Reinforced 25.31 BDF 5 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / Bd.F.5 Page One One Cubic Metre 13783 5252
Cement Concrete granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or Number 300 and B.7,
as directed including steel centering, formwork, cover blocks, laying/pumping, Page.One Number 38
compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum
thickness to give a smooth and even surface or roughening if special finish is to
be provided and curing etc. complete.(Excluding reinforcement and structural
steel).with fully automatic micro processor based PLC with SCADA enabled reversible
Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine
aggregate (Crushed sand VSI Grade)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

842 Reinforced 25.33 BDF 5 Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / Bd.F.5 Page One One Cubic Metre 13967 5252
Cement Concrete granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and Number 300 and
drawings or as directed including steel centering, formwork, cover blocks, B-7,Page No 38.
laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of
sufficient minimum thickness to give a smooth and even surface or roughening if special
finish is to be provided and curing etc. complete,(Excluding reinforcement and structural
steel).with fully automatic micro processor based PLC with SCADA enabled reversible
Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine
aggregate (Crushed sand VSI Grade)

843 Reinforced 25.35 BDF 5 Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / Bd.F.5 Page One One Cubic Metre 14150 5252
Cement Concrete granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or Number 300 and B.7,
as directed including steel centering, formwork,cover blocks, laying/pumping, compaction Page.One Number 38
finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to
give a smooth and even surface or roughening if special finish is to be
provided and curing etc. complete,(Excluding reinforcement and structural steel). with
fully automatic micro processor based PLC with SCADA enabled reversible Drum Type
mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed
sand VSI Grade)

844 Reinforced 25.37 BDF 5 Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap / Bd.F.5 Page One One Cubic Metre 14242 5252
Cement Concrete granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or Number 300 and B.7,
as directed including steel centering, formwork, cover blocks, laying/pumping, Page.One Number 38
compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum
thickness to give a smooth and even surface or roughening if special finish is to
be provided and curing etc. complete,(Excluding reinforcement and structural
steel).with fully automatic micro processor based PLC without SCAD Aenabled reversible
Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine
aggregate (Crushed sand VSI Grade)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

845 Reinforced 25.39 BDF 5 Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / Bd.F.5 Page One One Cubic Metre 14333 5252
Cement Concrete granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or Number 300 and B.7,
as directed including steel centering, formwork, cover blocks, laying/pumping, Page.One Number 38
compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum
thickness to give a smooth and even surface or roughening if special finish is to
be provided and curing etc. complete,(Excluding reinforcement and structural
steel).with fully automatic micro processor based PLC with SCADA enabled reversible
Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine
aggregate (Crushed sand VSI Grade)

846 Reinforced 25.50 BDF 6 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / Bd.F.6 Page One One Cubic Metre 12269 5085
Cement Concrete granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and Number 300 and
drawings or as directed including steel centering, formwork, cover blocks, B.7, Page One
laying/pumping, compactionand roughening the surface if special finish is to be Number38
provided and curing etc. complete. (Excluding reinforcement and structural steel).
with fully automatic micro processor based PLC with SCADA enabled reversible
Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine
aggregate (Crushed sand VSI Grade)

847 Reinforced 25.52 BDF 6 Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ Bd.F.6 Page One One Cubic Metre 12452 5085
Cement Concrete granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and Number 300 and
drawings or as directed including steel centering, formwork, cover blocks, B.7, Page One
laying/pumping, compactionand roughening the surface if special finish is to be provided Number38
and curing etc. complete. (Excluding reinforcement and structural steel).with fully
automatic micro processor based PLC with SCADA enabled reversible Drum Type
mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate
(Crushed sand VSI Grade)

848 Reinforced 25.54 BDF 6 Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / Bd.F.6 Page One One Cubic Metre 12635 5085
Cement Concrete granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and Number 300 and
drawings or as directed including steel centering, formwork, cover blocks, B.7, Page One
laying/pumping, compactionand roughening the surface if special finish is to be Number38
provided and curing etc. complete. (Excluding reinforcement and structural steel).with
fully automatic micro processor based PLC with SCADA enabled reversible Drum Type
mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed
sand VSI Grade)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

849 Reinforced 25.56 BDF 6 Providing and laying Cast in situ/Ready Mixcement concrete M-35 of trap / granite Bd.F.6 Page One One Cubic Metre 12727 5085
Cement Concrete /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings Number 300 and
or as directed including steel centering, formwork, cover blocks, laying/pumping, B.7, Page One
compactionand roughening the surface if special finish is to be provided and curing etc. Number38
complete. (Excluding reinforcement and structural steel).with fully automatic micro
processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete
Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI
Grade)

850 Reinforced 25.58 BDF 6 Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / Bd.F.6 Page One One Cubic Metre 13002 5085
Cement Concrete granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and Number 300 and
drawings or as directed including steel centering, formwork, cover blocks, B.7, Page One
laying/pumping, compactionand roughening the surface if special finish is to be Number38
provided and curing etc. complete. (Excluding reinforcement and structural steel).
with fully automatic micro processor based PLC with SCADA enabled reversible
Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine
aggregate (Crushed sand VSI Grade)

851 Reinforced 25.70 BDF 8 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ Bd.F.8 Page One One Cubic Metre 13932 5988
Cement Concrete granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs Number 302 and
and drawings including steel centering, formwork, cover blocks, laying/pumping, B.7, Page One
compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum Number38
thickness to give a smooth and even surface or roughening if special finish is to
be provided and curing etc. complete,(Excluding reinforcement and structural
steel).with fully automatic micro processor based PLC with SCADA enabled reversible
Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine
aggregate (Crushed sand VSI Grade)

852 Reinforced 25.72 BDF 8 Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ Bd.F.8 Page One One Cubic Metre 14116 5988
Cement Concrete granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs Number 302 and
and drawings including steel centering, formwork, cover blocks, laying/pumping, B.7, Page One
compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum Number38
thickness to give a smooth and even surface or roughening if special finish is to
be provided and curing etc. complete,(Excluding reinforcement and structural
steel).with fully automatic micro processor based PLC with SCADA enabled reversible
Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine
aggregate (Crushed sand VSI Grade)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

853 Reinforced 25.74 BDF 8 Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ Bd.F.8 Page One One Cubic Metre 14299 5988
Cement Concrete granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs Number 302 and
and drawings including steel centering, formwork, cover blocks, laying/pumping, B.7, Page One
compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum Number38
thickness to give a smooth and even surface or roughening if special finish is to
be provided and curing etc. complete,(Excluding reinforcement and structural
steel).with fully automatic micro processor based PLC with SCADA enabled reversible
Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine
aggregate (Crushed sand VSI Grade)

854 Reinforced 25.76 BDF 8 Providing and laying Cast in situ/Ready Mix cement concrete M-35 of trap/ Bd.F.8 Page One One Cubic Metre 14391 5988
Cement Concrete granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs Number 302 and
and drawings including steel centering, formwork, cover blocks, laying/pumping, B.7, Page One
compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum Number38
thickness to give a smooth and even surface or roughening if special finish is to
be provided and curing etc. complete,(Excluding reinforcement and structural steel).
with fully automatic micro processor based PLC with SCADA enabled reversible Drum
Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate
(Crushed sand VSI Grade)

855 Reinforced 25.78 BDF 8 Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap/ Bd.F.8 Page One One Cubic Metre 14666 5988
Cement Concrete granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs Number 302 and
and drawings including steel centering, formwork, cover blocks, laying/pumping, B.7, Page One
compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum Number38
thickness to give a smooth and even surface or roughening if special finish is to
be provided and curing etc. complete,(Excluding reinforcement and structural
steel).with fully automatic micro processor based PLC with SCADA enabled reversible
Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine
aggregate (Crushed sand VSI Grade)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

SSR 2022-23 :- Reinforced Cement Concrete


856 Reinforced 26.05 BDF 9 Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ Bd.F.9 Page One One Cubic Metre 13932 5988
Cement Concrete quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including Number 303 and
steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the B.7, Page One
surface if special finish is to be provided and curing complete. (Excluding reinforcement Number38
and structural steel). with fully automatic micro processor based PLC with SCADA
enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc.
complete. With fine aggregate (Crushed sand VSI Grade)

857 Reinforced 26.07 BDF 9 Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ Bd.F.9 Page One One Cubic Metre 14116 5988
Cement Concrete quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including Number 303 and
steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the B.7, Page One
surface if special finish is to be provided and curing complete. (Excluding reinforcement Number38
and structural steel). with fully automatic micro processor based PLC with SCADA
enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc.
complete. With fine aggregate (Crushed sand VSI Grade)

858 Reinforced 26.09 BDF10 Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / Bd.F.8 Page One One Cubic Metre 13932 5988
Cement Concrete granite / quartzite / gneiss metal for R.C.C. canopy as per detailed designs and Number 303 and
drawings including steel centering, formwork, laying/pumping, compacting and B.7, Page One
roughening the surface if special finish is to be provided and curing etc. complete Number38
(excluding reinforcement), with fully automatic micro processor based PLC with
SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc.
complete. With fine aggregate (Crushed sand VSI Grade)
859 Reinforced 26.11 BDF10 Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / Bd.F.8 Page One One Cubic Metre 14116 5988
Cement Concrete granite / quartzite / gneiss metal for R.C.C. canopy as per detailed designs and Number 303 and
drawings including steel centering, formwork, laying/pumping, compacting and B.7, Page One
roughening the surface if special finish is to be provided and curing etc. complete Number38
(excluding reinforcement). with fully automatic micro processor based PLC with
SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc.
complete. With fine aggregate (Crushed sand VSI Grade)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

860 Reinforced 26.17 BDF 11 Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ Bd.F.11 Page One One Cubic Metre 15567 7338
Cement Concrete granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including Number 304 and
steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing B.7, Page One
and rougheningthem if special finish is to be provided and curing Number 38
complete.(Excluding reinforcement and structural steel).with fully automatic micro
processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete
Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

861 Reinforced 26.19 BDF 11 Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ Bd.F.11 Page One One Cubic Metre 15750 7338
Cement Concrete granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including Number 304 and
steel centering, formwork, cover blocks, laying/pumping, compacting and roughening B.7, Page One
them if special finish is to be provided and curing complete. (Excluding Number 38
reinforcement and structural steel).with fully automatic micro processor based PLC
with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan
mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

862 Reinforced 26.23 BDF 12 Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ Bd. F. 12 Page One One Cubic Metre 7190 2196
Cement Concrete granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and Number 304 and
windows moulded as per detailed drawings or chamfered as approved by the Engineer B-7, Pg 38
including steel centering, formwork, cover blocks, laying/pumping, compacting ,
curing , finishing and roughening them if special finish is to be provided and
curing complete. (Excluding reinforcement and structural steel).with fully automatic
micro processor based PLC with SCADA enabled reversible Drum Type mixer/
concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed
sand VSI Grade)

863 Reinforced 26.25 BDF 13A Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap / Bd. F. 13 Page One One Cubic Metre 12060 5219
Cement Concrete quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per Number 305
detailed design and drawings or as directed including steel centering, formwork, /I.S. 456 (2000
steel props, laying/pumping, compaction, finishing uneven and honeycombed surface
with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or
roughening the surface if special finish is to be provided and curing etc. complete.
(Excluding einforcement, including cover block).(Newly laid concrete shall be covered by
gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with
SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc.
complete. With fine aggregate (Crushed sand VSI Grade)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

864 Reinforced 26.26 BDF 13A Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / Bd. F. 13 Page One One Cubic Metre 12244 5219
Cement Concrete quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per Number 305
detailed design and drawings or as directed including steel centering, plywood/ steel /I.S. 456 (2000
formwork, steel props, laying/pumping, compaction, finishing uneven and
honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth
and even surface or roughening the surface if special finish is to be provided and curing
etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall
be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

865 Reinforced 26.27 BDF 14A Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap / Bd. F. 14 Page One One Cubic Metre 12805 4861
Cement Concrete quartzite/granite /gneiss metal for R.C.C.newel posts of staircase as per detailed design Number 305
and drawings including steel centering, plywood / steel formwork, steel props, /I.S. 456 (2001
laying / pumping, compaction, finishing uneven and honeycombed surface with
C.M.1:3 of sufficient minimum thickness to give a smooth and even surface or
roughening the surface if special finish is to be provided and curing etc. complete.
(Excluding reinforcement, including cover block). (Newly laid concrete shall be
covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)

866 Reinforced 26.28 BDF 14A Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / Bd. F. 14 Page One One Cubic Metre 12989 4861
Cement Concrete quartzite/granite /gneiss metal for R.C.C.newel posts of staircase as per detailed design Number 305
and drawings including steel centering, plywood / steel formwork, steel props, /I.S. 456 (2002
laying/pumping, compaction, finishing uneven and honeycombed surface with C.M.1:3 of
sufficient minimum thickness to give a smooth and even surface or roughening the surface
if special finish is to be provided and curing etc. complete. (Excluding reinforcement,
including cover block). (Newly laid concrete shall be covered by gunny bag, plastic,
tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled
reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With
fine aggregate (Crushed sand VSI Grade)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

867 Reinforced 26.29 BDF 15A Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap Bd. F. 15 Page One One Cubic Metre 14136 5393
Cement Concrete /granite / gneiss/ quartzite metal for R.C.C. arches with skew backs as per detailed design Number 306
and drawings or as directed including steel centering, plywood/steel formwork, steel /I.S. 456 (2003
props, laying/pumping, compaction, finishing uneven and honeycombed surface with
C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or
roughening the surface if special finish is to be provided and curing etc. complete.
(Excluding reinforcement, including cover block). Newly laid concrete shall be covered by
gunny bag, plastic, tarpaulin etc. with fully automatic micro processor based PLC with
SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc.
complete. With fine aggregate (Crushed sand VSI Grade)

868 Reinforced 26.30 BDF 15A Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap Bd. F. 15 Page One One Cubic Metre 14319 5393
Cement Concrete /granite / gneiss/ quartzite metal for R.C.C. arches with skew backs as per detailed design Number 306
and drawings or as directed including steel centering, plywood/steel formwork, steel /I.S. 456 (2003
props, laying/pumping, compaction, finishing uneven and honeycombed surface with
C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or
roughening the surface if special finish is to be provided and curing etc. complete.
(Excluding reinforcement, including cover block). Newly laid concrete shall be covered by
gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed) With fine
aggregate (Crushed sand VSI Grade)

869 Reinforced 26.31 BDF 16 Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap / Bd. F. 16 Page One One Cubic Metre 17601 8136
Cement Concrete granite/gneiss / quartzite metal for R.C.C. fins of required thickness in position as Number 306
shown on the drawings or as directed by Engineer-in-charge including steel /I.S. 456 (2004
centering, plywood / steel formwork, steel props, laying/pumping, compaction,
finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum
thickness to give a smooth and even surface or roughening the surface if special finish is
to be provided and curing etc. complete. (Excluding reinforcement, including cover
block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. with
fully automatic micro processor based PLC with SCADA enabled reversible Drum Type
mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed
sand VSI Grade)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

870 Reinforced 26.32 BDF 16 Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / Bd. F. 16 Page One One Cubic Metre 17785 8136
Cement Concrete granite/gneiss / quartzite metal for R.C.C. fins of required thickness in position as Number 306
shown on the drawings or as directed by Engineer-in-charge including steel /I.S. 456 (2004
centering, plywood / steel formwork, steel props, laying/pumping, compaction,
finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum
thickness to give a smooth and even surface or roughening the surface if special finish is
to be provided and curing etc. complete. (Excluding reinforcement, including cover
block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. with
fully automatic micro processor based PLC with SCADA enabled reversible Drum Type
mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed
sand VSI Grade)

871 Reinforced 26.33 BDF 17 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters Bd.F.17, Page One Metric Tonne 89703 11762
Cement Concrete for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, Number 306
staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed
designs, drawings and schedules. including cutting, bending, hooking the bars, binding
with wires or tack welding and supporting as required complete.

872 Reinforced 26.34 BDF 17 Providing and fixing in position HCRM / CRS (Corrosion Resistant Steel) bar Bd.F.17, Page One Metric Tonne 94136 11880
Cement Concrete reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, Number 306
beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins,
arches etc. as per detailed designs, drawings and schedules. including cutting, bending,
hooking the bars, binding with wires or tack welding and supporting as required complete.

873 Reinforced 26.36 Providing and applying Anti corrosive treatment to reinforcement as per cement As directed by Metric Tonne 11287 6562
Cement Concrete polymer composite coating (C.P.C.C.) method developed by C.E.C.R.I. including Engineer in Charge
cleaning the bar by means of any established mechanical or manual method for
removing rust and deleterious material, applying rapid setting primer and cement
polymer sealing coat of approved and licensed by CECRI including redoing the
process if damage occurs during handling, stacking etc. complete. (With prior approval of
SE)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

874 Reinforced 26.37 MORT and H 1600 Providing Fusion Bonded Epoxy Coating (FBEC) to reinforced bars of 8mm diameter as As directed by Metric Tonne 24710 1024
Cement Concrete Edition per IS: 13620-1993 specifications for a thickness of 175micron Permissible variation Engineer in Charge
2001. of 50 micron including testing of coating at plant, including cost for careful handling
using PVC coating, binding wires instead of G. I. wires to and from Plant)
touching up the material supplied repair work etc complete as per detailed
specifications. (Lead 200km from plant) etc complete. (Item shall be used for new
structures.)
Note : The item should be executed with prior approval of Superintending Engineer.
FREQUENCY OF TEST OF FUSION BONDED EPOXY COAT
a) Coating thickness shall be tested at a frequency of not less than one full length bar
every twenty bars for each size
b) continuity of coating shall be determined by testing one full length bar in every twenty
bars for each size
c) Coating thickness over the whole of the coated bar section shall be determined
by sectioning and examining one bar in every twenty tonnes for each size.
d) For testing adhesion of coating, samples shall be selected from each size according to
the frequency given below:
Nominal Size of Bar, MM One Number of Samples
For all types of bar : Minimum 1 for every diameter or as directed by engineer in charge
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

875 Reinforced 26.38 MORT and H 1600 Providing Fusion Bonded Epoxy Coating (FBEC) to reinforced bars of 10mm diameter As directed by Metric Tonne 19640 1024
Cement Concrete Edition as per IS: 13620-1993 specifications for a thickness of 175micron Permissible variation of Engineer in Charge
2001. 50 micron including testing of coating at plant, including cost for careful handling using
PVC coating, binding wires instead of G. I. wires to and from Plant) touching up
the material supplied repair work etc complete as per detailed specifications. (Lead
200km from plant) etc complete. (Item shall be used for new structures.)
Note : The item should be executed with prior approval of Superintending Engineer.
FREQUENCY OF TEST OF FUSION BONDED EPOXY COAT
a) Coating thickness shall be tested at a frequency of not less than one full length bar
every twenty bars for each size
b) continuity of coating shall be determined by testing one full length bar in every twenty
bars for each size
c) Coating thickness over the whole of the coated bar section shall be determined
by sectioning and examining one bar in every twenty tonnes for each size.
d) For testing adhesion of coating, samples shall be selected from each size according to
the frequency given below:
For all types of bar : Minimum 1 for every diameter or as directed by engineer in charge
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

876 Reinforced 26.39 MORT and H 1600 Providing Fusion Bonded Epoxy Coating (FBEC) to reinforced bars of 12mm diameter As directed by Metric Tonne 16896 1024
Cement Concrete Edition as per IS: 13620-1993 specifications for a thickness of 175micron Permissible variation of Engineer in Charge
2001. 50 micron including testing of coating at plant, including cost for careful handling using
PVC coating, binding wires instead of G. I. wires to and from Plant) touching up
the material supplied repair work etc complete as per detailed specifications. (Lead
200km from plant) etc complete. (Item shall be used for new structures.)
Note : The item should be executed with prior approval of Superintending Engineer.
FREQUENCY OF TEST OF FUSION BONDED EPOXY COAT
a) Coating thickness shall be tested at a frequency of not less than one full length bar
every twenty bars for each size
b) continuity of coating shall be determined by testing one full length bar in every twenty
bars for each size
c) Coating thickness over the whole of the coated bar section shall be determined
by sectioning and examining one bar in every twenty tonnes for each size.
d) For testing adhesion of coating, samples shall be selected from each size according to
the frequency given below:
For all types of bar : Minimum 1 for every diameter or as directed by engineer in charge
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

877 Reinforced 26.40 MORT and H 1600 Providing Fusion Bonded Epoxy Coating (FBEC) to reinforced bars of 16mm diameter As directed by Metric Tonne 13108 1024
Cement Concrete Edition as per IS: 13620-1993 specifications for a thickness of 175micron Permissible variation of Engineer in Charge
2001. 50 micron including testing of coating at plant, including cost for careful handling using
PVC coating, binding wires instead of G. I. wires to and from Plant) touching up
the material supplied repair work etc complete as per detailed specifications. (Lead
200km from plant) etc complete. (Item shall be used for new structures.)
Note : The item should be executed with prior approval of Superintending Engineer.
FREQUENCY OF TEST OF FUSION BONDED EPOXY COAT
a) Coating thickness shall be tested at a frequency of not less than one full length bar
every twenty bars for each size
b) continuity of coating shall be determined by testing one full length bar in every twenty
bars for each size
c) Coating thickness over the whole of the coated bar section shall be determined
by sectioning and examining one bar in every twenty tonnes for each size.
d) For testing adhesion of coating, samples shall be selected from each size according to
the frequency given below:
For all types of bar : Minimum 1 for every diameter or as directed by engineer in charge
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

878 Reinforced 26.41 MORT and H 1600 Providing Fusion Bonded Epoxy Coating (FBEC) to reinforced bars of 20mm diameter As directed by Metric Tonne 10841 1024
Cement Concrete Edition as per IS: 13620-1993 specifications for a thickness of 175micron Permissible variation of Engineer in Charge
2001. 50 micron including testing of coating at plant, including cost for careful handling using
PVC coating, binding wires instead of G. I. wires to and from Plant) touching up
the material supplied repair work etc complete as per detailed specifications. (Lead
200km from plant) etc complete. (Item shall be used for new structures.)
Note : The item should be executed with prior approval of Superintending Engineer.
FREQUENCY OF TEST OF FUSION BONDED EPOXY COAT
a) Coating thickness shall be tested at a frequency of not less than one full length bar
every twenty bars for each size
b) continuity of coating shall be determined by testing one full length bar in every twenty
bars for each size
c) Coating thickness over the whole of the coated bar section shall be determined
by sectioning and examining one bar in every twenty tonnes for each size.
d) For testing adhesion of coating, samples shall be selected from each size according to
the frequency given below:
For all types of bar : Minimum 1 for every diameter or as directed by engineer
in chargecharge

879 Reinforced 26.42 MORT and H 1600 Providing Fusion Bonded Epoxy Coating (FBEC) to reinforced bars of 25mm diameter As directed by Metric Tonne 9051 1024
Cement Concrete Edition as per IS: 13620-1993 specifications for a thickness of 175micron Permissible variation of Engineer in Charge
2001. 50 micron including testing of coating at plant extra cost for careful handling using PVC
coating, binding wires instead of G. I. wires to and from Plant) touching up the
material supplied repair work etc complete as per detailed specifications. (Lead
200km from plant) etc complete. (Item shall be used for new structures.) Note : The item
should be executed with prior approval of Superintending Engineer. charge
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

880 Reinforced 26.44 MORT and H 1600 Providing Fusion Bonded Epoxy Coating (FBEC) to reinforced bars of 32mm diameter As directed by Metric Tonne 7411 1024
Cement Concrete Edition as per IS: 13620-1993 specifications for a thickness of 175micron Permissible variation of Engineer in Charge
2001. 50 micron including testing of coating at plant extra cost for careful handling using PVC
coating, binding wires instead of G. I. wires to and from Plant) touching up the
material supplied repair work etc complete as per detailed specifications. (Lead
200km from plant) etc complete. (Item shall be used for new structures.)
Note : The item should be executed with prior approval of Superintending Engineer.
FREQUENCY OF TEST OF FUSION BONDED EPOXY COAT
a) Coating thickness shall be tested at a frequency of not less than one full length bar
every twenty bars for each size
b) continuity of coating shall be determined by testing one full length bar in every twenty
bars for each size
c) Coating thickness over the whole of the coated bar section shall be determined
by sectioning and examining one bar in every twenty tonnes for each size.
d) For testing adhesion of coating, samples shall be selected from each size according to
the frequency given below:
For all types of bar : Minimum 1 for every diameter or as directed by engineer in charge

881 Reinforced 26.46 BDF 20 Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali Bd. F. 20 Page One One Square 937 158
Cement Concrete 50 mm thick with 3 mm diameter mild steel bar reinforcement, of approved design on Number 307 Metre
both side, fixing in cement mortar 1:3 and curing etc. complete

882 Reinforced 26.47 BDF 20 Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali Bd. F. 20 Page One One Square 1193 158
Cement Concrete 80 mm thick with 3 mm diameter mild steel bar reinforcement, of approved design on Number 308 Metre
both sides, fixing in cement mortar 1:3 and curing etc .complete.

883 Reinforced 26.58 BDF 41 Providing and laying Cast in situ/Ready Mix C.C. M-20 of trap metal for RCC rectangular Bd.F.6, Page One One Cubic Metre 15094 7149
Cement Concrete grid beam with slab as per detailed design and drawing, steel centering, formwork, Number300 /
cover blocks, laying/pumping, compacting, curing, finishing and roughening them to Bd.F.8, Page One
form surface with C.M. 1:3 of sufficient minimum thickness to give smooth and Number302 and
even surface or roughening them if special finish is to be provided and curing B.7 Page One
complete (Excluding reinforcement and structural steel). with fully automatic micro Number 38.
processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete
Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI
Grade)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

884 Reinforced 26.60 BDF 41 Providing and laying Cast in situ/Ready Mix C.C. M-25 of trap metal for RCC rectangular Bd.F.6, Page One One Cubic Metre 15277 7149
Cement Concrete grid beam with slab as per detailed design and drawing or as directed including Number300 /
dewatering if necessary, steel centering, formwork, cover blocks, laying/pumping, Bd.F.8, Page One
compacting, finishing the form surface with C.M. 1:3 of sufficient minimum thickness to Number302 and
give smooth and even surface or roughening them if special finish is to be provided B.7 Page One
and curing complete (Excluding reinforcement and structural steel). with fully Number 38.
automatic micro processor based PLC with SCADA enabled reversible Drum Type
mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate
(Crushed sand VSI Grade)

885 Reinforced 26.62 BDF 41 Providing and laying Cast in situ/Ready Mix C.C. M-30 of trap metal for RCC rectangular Bd.F.6, Page One One Cubic Metre 15461 7149
Cement Concrete grid beam with slab as per detailed design and drawing or as directed including Number300 /
dewatering if necessary, steel centering, formwork, cover blocks, Bd.F.8, Page One
laying/pumping,compacting , curing , finishing and roughening them to form surface Number302 and
with C.M. 1:3 of sufficient minimum thickness to give smooth and even surface or B.7 Page One
roughening them if special finish is to be provided and curing complete (Excluding Number 38.
reinforcement and structural steel). with fully automatic micro processor based PLC
with SCADA enabled concrete batch mix plant (pan mixer). With fine aggregate (Crushed
sand VSI Grade)
886 Reinforced 26.64 BDF Providing and laying Cast in situ/Ready Mix C.C. M-35 of trap metal for RCC rectangular Bd.E.2 Page One One Cubic Metre 15549 7149
Cement Concrete grid beam with slab as per detailed design and drawing or as directed including Number 288 and
dewatering if necessary, steel centering, formwork, cover blocks, laying/pumping, B.7 Page No 38
compacting, finishing the form surface with C.M. 1:3 of sufficient minimum thickness to
give smooth and even surface or roughening them if special finish is to be provided
and curing complete (Excluding reinforcement and structural steel). with fully
automatic micro processor based PLC with SCADA enabled reversible Drum Type
mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate
(Crushed sand VSI Grade)
887 Reinforced 26.66 BDF 41 Providing and laying Cast in situ/Ready Mix C.C. M-40 of trap metal for RCC rectangular Bd.E.4 Page One One Cubic Metre 15827 7149
Cement Concrete grid beam with slab as per detailed design and drawing or as directed including Number 289 and B-
dewatering if necessary, steel centering, formwork, cover blocks, 7, Page One
laying/pumping,compacting, finishing the form surface with C.M. 1:3 of sufficient Number38
minimum thickness to give smooth and even surface or roughening them if special
finish is to be provided and curing complete (Excluding reinforcement and
structural steel). with fully automatic micro processor based PLC with SCADA
enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc.
complete. With fine aggregate (Crushed sand VSI Grade)
Sr. Chapter SSR Item Reference No. Description of the item Additional Unit Completed Labour
No. No. Specification Rate for Rate for
2022-23 2022-23
excluding excluding
GST GST
In Rs. In Rs.

888 Reinforced 26.68 BDF Providing and fixing during laying in RCC Slab rectangular 2 mm thick M.S. sheet fan As directed by One Number 397 30
Cement Concrete hook box of size 180x100 mm with required depth with holes or notches as required, Engineer in charge
bottom and top sides of 1.6 mm M.S. sheet fixed with 3.5 mm dia. round headed screws
together with 12 mm dia. M.S. bar bent to shape with hooked ends for fan hook and
painting to exposed surface