Safe Press. 10 Oil FM M-3 To M-1D

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

Battelle

Line Name: 10" oil fm M-3 to M-1 D

Input Data
D Outside diameter, (in) 10.75
t Wall thickness, (in) 0.5
S Yield strength, (psi) 35000
F Design factor (0.72 - 0.4) 0.6
0.72: cross country, 0.4: in plant, 0.6: riser

MAOP Max. allowable operating pressure, (psi) 150


L Length of corrosion, (in) 8
d Depth of corrosion, (in) 0.236
I Intermed factor
E Longitudinal joint factor 1
T Temp. derating factor 1

Output Data
Design pressure [ P=2StFET/D ], psi 1953
Intermed factor [ I=0.893L/SQRT(Dt) ] 3.08
Corrosion reduction [ =d/t ] 0.47
Safe pressure ( P' ), psi 1631
[ IF I>4, P'=1.1P(1-d/t) ]
[ IF I<=4, P'=1.1P{(1-2/3*d/t)/(1-2/3*d/t*1/SQRT(I^2+1))} ]

Conclusion

Pipe is Acceptable
In-Plant
Line Name: 8" oil from R-4 Dto R-6 (riser #2)

Input Data
D Outside diameter, (in) 18
t Wall thickness, (in) 0.5
S Allowable stress, (psi) 20000
E Long. Joint factor 1
1: Seamless, 0.85: ERW
y 0.4

MAOP Max. allowable operating pressure, (psi) 100


L Length of corrosion, (in) 12
d Depth of corrosion, (in) 0.343
I Intermed factor

Output Data
Design pressure [ P=2StE/(D-2yt) ], psi 1136
Intermed factor [ I=0.893L/SQRT(Dt) ] 3.57
Corrosion reduction [ =d/t ] 0.69
Safe pressure ( P' ), psi 774
[ IF I>4, P'=1.1P(1-d/t) ]
[ IF I<=4, P'=1.1P{(1-2/3*d/t)/(1-2/3*d/t*1/SQRT(I^2+1))} ]

Conclusion

Pipe is Acceptable

You might also like