SC Series - SC3020 Replacement-I - O Card
SC Series - SC3020 Replacement-I - O Card
Topic
SC3020 Replacement
Selections
Choose an Option: I/O Card
REPORT PROBLEMS
If you find any errors in this procedure or have comments regarding this application, send email to
SolVeFeedback@dell.com
Copyright © 2023 Dell Inc. or its subsidiaries. All Rights Reserved. Dell Technologies, Dell, EMC, Dell
EMC and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be
trademarks of their respective owners.
The information in this publication is provided “as is.” Dell Inc. makes no representations or warranties of
any kind with respect to the information in this publication, and specifically disclaims implied warranties of
merchantability or fitness for a particular purpose.
Use, copying, and distribution of any software described in this publication requires an applicable
software license.
This document may contain certain words that are not consistent with Dell's current language guidelines.
Dell plans to update the document over subsequent future releases to revise these words accordingly.
This document may contain language from third party content that is not under Dell's control and is not
consistent with Dell's current guidelines for Dell's own content. When such third party content is updated
by the relevant third parties, this document will be revised accordingly.
Page 1 of 7
Contents
Preliminary Activity Tasks .......................................................................................................3
Read, understand, and perform these tasks.................................................................................................3
I/O Card...................................................................................................................................4
Identify Failed IO Card ............................................................................................................4
Remove an I/O Card From Riser 1 .........................................................................................4
Install an I/O Card in Riser 1...................................................................................................5
Page 2 of 7
Preliminary Activity Tasks
This section may contain tasks that you must complete before performing this procedure.
Table 1 List of cautions, warnings, notes, and/or KB solutions related to this activity
2. This is a link to the top trending service topics. These topics may or not be related to this activity.
This is merely a proactive attempt to make you aware of any KB articles that may be associated with
this product.
Note: There may not be any top trending service topics for this product at any given time.
Page 3 of 7
I/O Card
The storage controller supports a single I/O card in one PCI slot.
The following types of I/O cards can be used for front-end connectivity:
• Fibre Channel
• iSCSI
• SAS
• Use Dell Storage Manager to edit the Storage Center settings and set the operation mode of the
Storage Center to Maintenance mode.
Steps
5. Install the service baffle into the empty slot in the chassis.
Page 4 of 7
6. Remove the cover of the storage controller.
7. Lift the blue latch that secures the riser to the side of the storage controller.
8. Rotate the latch toward the outside of the storage controller.
9. Remove the riser that holds the I/O card in the storage controller.
10. Loosen the blue thumbscrew that holds the I/O card retainer against the back of the I/O card.
11. Rotate the I/O retainer away from the I/O card.
12. Grasp the I/O card by its edges, and remove it from the I/O card slot.
1. I/O card
2. Latch
3. Thumbscrew
4. Retainer
1. Unpack the replacement I/O card, and prepare it for installation. For instructions, see the
documentation accompanying the I/O card.
2. Holding the I/O card by its edges, position the card so that the card�edge connector aligns with
the I/O card connector on the riser.
Page 5 of 7
Figure 1. I/O Card Connector Location on Riser 1
1. Card connector
3. Insert the card–edge connector firmly into the I/O card connector until the card is fully seated.
CAUTION: Make sure that the I/O card is fully seated in the I/O card connector. An I/O card that is
not in full contact with the connector might cause unpredictable failures in the SCv3000 and
SCv3020 storage system.
4. Swing the I/O card retainer so that the retainer is flush with the back of the I/O card.
1. I/O card
2. Latch
3. Thumbscrew
4. Retainer
Page 6 of 7
6. Tighten the blue thumbscrew on the back of the retainer to hold the I/O card in place.
7. Insert the riser into the storage controller.
8. Lower the latch to hold the riser in place.
9. Replace the cover on the storage controller.
10. Remove the service baffle from the chassis.
CAUTION: To prevent a thermal shutdown of the storage system, the storage controller must be
installed within three minutes of removing the service baffle.
1. Use Dell Storage Manager to edit the Storage Center settings and set the operation mode of the
Storage Center to Production mode.
2. Use Dell Storage Manager to send SupportAssist information to technical support.
Page 7 of 7