Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

12

SECTION 5
REPLACEMENT PARTS
Pressure Drop Curve for the Triton® Series Fiberglass Sand Filters
Pressure
Curva Lossde
de Caída Curves (TR40,
Presión TR50,
(TR40, TR60)
TR50, TR60) Pressure Loss Curves (TR100C/TR100HD, TR100C-3/TR140C-3, TR140C)
8 16

7 14

6 12
(Ft.)
Loss (ft)

5 10

Pressure Loss (ft)


de Presión

4 TR40 8 TR100C/TR100HD
Pressure

TR50 TR100C-3/TR140 C-3


Caída

TR60 TR140C
3 6

2 4

1 2

0 0
0 10 20 30 40 50 60 70 0 20 40 60 80 100 120 140 160
Flowde
Índice Rate (GPM)
Flujo (GPM) Flow Rate (GPM)

Pressure Loss Curves (TR100, TR140)


20

18

16

14
Pressure Loss (ft)

12

10
TR100
TR140
8

0
0 20 40 60 80 100 120 140 160
Flow Rate (GPM)

Installing Multiple Filters with Tandem Filter Piping Kits


CAUTION: WHEN MULITPLE FILTERS ARE
INSTALLED, WE HIGHLY RECOMMEND
THE USE OF A PENTAIR TANDEM FILTER FIGURE A.
PIPING KIT. THESE KITS INCLUDE
PLUMBING SUPPORTS (BETWEEN INLET
INLET AND OUTLET PIPING AND
BETWEEN OUTLET PIPING AND
FLOOR) TO ASSURE INTEGRITY
OF THE INSTALLATION.
SEE FIGURE A. OUTLET

CAUTION: PENTAIR RECOMMENDS THE


USE OF A TANDEM FILTER
PLUMBING KIT(S) OR SOME
SORT OF PLUMBING SUPPORT
TO ASSURE PLUMBING INTEGRITY.
FAILURE TO INCLUDE THESE SUPPORTS
COULD VOID YOUR WARRANTY.

TRITON® Fiberglass Sand Filter Installation and User’s Guide

You might also like