Professional Documents
Culture Documents
Case Study Window Regulator Assembly Line 2016 02 03 Case Study Window Regulator
Case Study Window Regulator Assembly Line 2016 02 03 Case Study Window Regulator
Case Study Window Regulator Assembly Line 2016 02 03 Case Study Window Regulator
Hankinson Inc.
Julian Hankinson
www.hankinsoninc.com
Performance & NVH Test Station
Accelerometer Actuators
Good Unit
0
1
1.4 1.45 1.5 1.55 1.6
Time [sec]
Rail Vibration Spectrums
0.05
Cable Grinding
No Cable Grinding
0.04
Band of Consistent
Difference
0.03
G rms
0.02
0.01
0
0 200 400 600 800 1000
Frequency [Hz]
Filtered & Enveloped Rail Vibration Data
Good Unit
0
1
1.4 1.45 1.5 1.55 1.6
Time [sec]
Spectrums of Enveloped Data
0.04
Good Unit
0.035 Moderate Cable Grinding
Severe Cable Grinding
0.03
Cable Coil
Pass Frequency
0.025
G rms
0.02
0.015
0.01
0.005
0
0 50 100 150 200
Frequency [Hz]
Statistical Analysis of Envelope Criteria
for Cable Grinding Issue
50
"Good" Units ( 3 )
"Bad" Units
40
Number of Units
30
20
Moderate Severe Cable
Cable Grinding Grinding
10
0
0 0.02 0.04 0.06
Envelope Magnitude @ Cable Pass Frequency
Statistical Analysis of Kurtosis Criteria
for Cable Grinding Issue
140
"Good" Units ( 3 )
120 "Bad" Units
100
Number of Units
80
60
40
20
0
2 3 4 5 6
Kurtosis
Acoustic Spectrum Comparison
for Motor Noise Issue
1
Volts peak
Quiet Motor
0.5
0
0 1000 2000 3000 4000 5000
1
Volts peak
0
0 1000 2000 3000 4000 5000
Frequency [Hz]
Statistical Analysis of High Frequency
Energy Band Criteria for Motor Noise Issue
100
"Good" Units ( 3 )
"Bad" Units
80
Number of Units
60
40
20
0
0 0.1 0.2 0.3 0.4 0.5 0.6
Frequency Band Energy, Motor Microphone