Download as pdf or txt
Download as pdf or txt
You are on page 1of 26

Portfolio Overview

3M Petrifilm
3M Clean Trace Hygiene Monitoring
3M Molecular Detection System

December 7th , 2017


Mathias Boldt, Scientific Marekting & Professional Service Manager
mboldt@mmm.com
A broad portfolio of solutions.
3M Food Safety
Quality Indicator Testing Pathogen Testing Sample Handling / Media

3M™ Petrifilm™ 3M™ Molecular 3M™ Sample


Plates Detection Handling Products
System

Hygiene Monitoring End-Product Screening Allergens

3M™ Clean -Trace™ 3M™ Microbial


Hygiene Monitoring Luminescence Introduction
System System Q1 2018, EMEA

6 December
© 3M 2017. All Rights Reserved. 2
Quelle: Pampers

6 December
© 3M 2017. All Rights Reserved. 3M Confidential. 3
3M™ Petrifilm™ Plates Quality Indicator Testing

Ready-to-use plates
3M™ Petrifilm™
Plates

product testing

environmental testing

Compliant to EU VO 2073
Compliant to ISO 11133:2014
6 December
© 3M 2017. All Rights Reserved. 3M Confidential. 4
3M Petrifilm

Plastic film
Adhesive + Indicator

Cold water soluble


gel
Standard nutrients
adhesive
Plastic coated paper
printed with
counting grid
There are just four steps needed

1 - Inoculation

2 – Spreading

3 - Incubation

4 - Reading
3M Petrifilm Portfolio
3M PF Aerobic Count 48h
3M PF Rapid Aerobic Count 24h
3M PF Enterobacteriaceae
3M PF Coliforms
3M PF Select E. Coli
3M PF E. Coli/Coliforms
3M PF High Sensitivity Coliforms
3M PF Rapid Coliform 6h
3M PF Yeast & Mold 5-7d
3M PF Rapid Yeast & Mold 48h (validated)
3M PF Lactic Acid Bacteria validated
3M PF Staph. Express 24 + 3h

3M PF Aqua Heterotrophic
3M PF Aqua Coliform
3M PF Aqua Enterobacteriaceae
3M PF Aqua Yeast & Mold
Validations
3M Petrifilm Reference method AFNOR Validation

3M™ Petrifilm™ Aerobic Counz ISO 4833:2003-06 Yes

3M™ Petrifilm™ Rapid Aerobic Count ISO 4833:2003-06 Yes (Dairy)

3M™ Petrifilm™ Lactic Acid Bacteria ISO 15214:1998-08 Yes

3M™ Petrifilm™ Coliforms ISO 4831:2006; ISO 4832:2006 Yes

3M™ Petrifilm™ Select E. coli ISO 16649-2 Yes

3M™ Petrifilm™ Staph Aureus Express ISO 6888-1:2003-1, 2 Yes

3M™ Petrifilm Enterobacteriaceae ISO 21528-2: 2004 Yes

3M™ Petrifilm Rapid Coliforms ISO 4831:2006, ISO 4832:2006 Yes

3M™ Petrifilm Highsensitivity Coliforms ISO 4831:2006, ISO 4832:2006 Yes

3M™ Petrifilm Rapid Yeast and Mold ISO 21527-1, ISO 21527-2 Yes
3M Petrifilm Innovations
3M Petrifilm Rapid Yeast and Mold Count
• AFNOR validated for 48h (60h) results
• Easy differentiation of yeast and molds

3M Petrifilm Rapid Aerobic Count


• AFNOR validated for dairy products

3M Petrifilm Lactic Acid


Bacteria Count
• AFNOR validated
• no anaerobic equipment
needed
• differentiation of homo-
and heterofermentives

9
3M Petrifilm and environmental testing
Facts and Figures
• International validations
• high reproduceability, consistent results
• 18 month shelf life
• high productivity
• new rapid methods allow early read and
results • high flexibility – tests can be repeated immediately
• results are comparable to reference methods as same
methodology is used
• low usage of consumables
• easy automation - but can always be used without
hardware
• no media preparation necessary
• second source of supply in Europe
Because you use Petrifilm versus traditional agar:

6 December
© 3M 2017. All Rights Reserved. 3M Confidential. 12
3M CleanTrace
Hygiene Monitoring
ATP Sources or
what should not be present after cleaning?
humans & animals!!

Microorganism
• bacteria
• yeast & mold

Food
• fruits Extra Terrestrians (E.T.)
• dairy products
• salad, vegetables
• meat
• etc…
3M™ Clean-Trace™ Hygiene Monitoring and Management System
The complete system:
• New lightweight luminometer design
with user-friendly touchscreen and
one-handed operation
• Test Swabs
• Powerful software

• eanbles total hygiene documentation


• ATP Surface (measure)

• ATP Water total/free (measure)

• Visual Inspection (document)

• Temperature (document)

• pH (document)

• free defined tests…

6 December
© 3M 2017. All Rights Reserved. 3M Confidential. 15
6 December
© 3M 2017. All Rights Reserved. 3M Confidential. 16
Power of data
Immediately identify cost savings
Identify potential increased costs
• Detailed view at a sample plan level
• Visualize trends
• By sample point
• By particular day or week
• Easy to interpret
• Align resources
• Justify resources
• Justify new resources

6 December
© 3M 2017. All Rights Reserved. 3M Confidential. 17
Master Sanitation Schedule

Immediately know where to align your limited


resources
• Detailed view at a sample plan level
• Quickly identify locations of current and potential issues
• Visualize trends
• By sample point
• By particular day or week

6 December
© 3M 2017. All Rights Reserved. 3M Confidential. 18
6 December
© 3M 2017. All Rights Reserved. 3M Confidential. 19
Advanced technology.
Simplified.
3M uses advanced technologies —
Isothermal DNA Amplification and
Bioluminescence Detection — to bring you
the 3M™ Molecular Detection System for an
accurate, reliable molecular solution with
increased productivity.

Colruyt Group, 13th November, 2017


Mathias Boldt, mboldt@mmm.com
2
0
What do our customers need in a pathogen system?

 Faster time to results


 Fewer false positives
 Easier to use
 Fewer transfer steps
 Regulatory approvals
 Intuitive software
 Robust hardware

7 December
© 3M 2017. All Rights Reserved. 21
Introducing the 3M™ Molecular Detection System

7 December
© 3M 2017. All Rights Reserved. 22
Simplified for productivity
3M Method 3M Method 3M Method 3M Method 3M Method
Salmonella E. coli O157 (including H7) Listeria Listeria monocytogenes Cronobacter
37°C ±1°C 37°C ±1°C
or 41.5°C ±1°C 41.5°C ±1°C 37°C ±1°C 37°C ±1°C 18-24 hrs
18-30 hrs 8-24 hrs 24-32 hrs 24-32 hrs*

*Raw dairy matrices


require 40 hrs.

Transfer 20 µL enriched sample to lysis tube.

Heat 15 minutes – 100°C ±1°C.


One
Cool 5 minutes on block at room temperature. Protocol
for All
Transfer 20 µL lysate to reagent tubes Pathogen
containing lyophilized pellet.
Targets
Place tubes in instrument.
Start run.
Amplification & detection in 15-75 minutes.
Automated & color-coded real-time results.

7 December
© 3M 2017. All Rights Reserved. 23
The next-generation of 3M™ Molecular Detection Assays

Introducing our newest assays:


3M™ Molecular Detection Assay 2 – Salmonella
3M™ Molecular Detection Assay 2 – Listeria
3M™ Molecular Detection Assay 2 – Listeria monocytogenes
3M™ Molecular Detection Assay 2 – E. coli O157 (including H7) • New chemistry based on 3M • Intuitive user interface for quick and
nanotechnology easy setup
3M™ Molecular Detection Assay 2 – Cronobacter • Unique color-change for increased • Real-time results help make critical
control decisions faster

New chemistry.
Faster time-to-result.
One protocol for all assays.
Streamlined workflow – now 30% faster. • Advanced isothermal technology • Compact instrument fits in any lab
overcomes limitation of older PCR and • All assays can be run simultaneously
antibody-based systems for optimal efficiency

7 December
© 3M 2017. All Rights Reserved. 24
3M Molecular Detection Assay 2 Protocol
Next Gen

Improved ease of use – 37% less handling.


Streamlined workflow – now 30% faster.
One protocol – all next-gen assays.

00:20:00

Advanced technology.
Simplified.

7 December
© 3M 2017. All Rights Reserved. 25
Mathias Boldt
3M Food Safety
Email: mboldt@mmm.com
Tel.: +49 170-7376809

6 December
© 3M 2017. All Rights Reserved. 3M Confidential. 26

You might also like