DESIGN BASIS REPORT

Table of Contents:

1.

Annuxure I : Design Information

1. Building Geomentry................................................................................2
2. Applicable Design Codes.......................................................................3
3. Design Loads...........................................................................................3
4. Design Assumptions.................................................................................

Annexure -I

1
Design Information

1.1 Building Geometry:

Building No : 01 Quantity of Buildings : 01


The Building is Made up of : 1 Area
Usage : GES-923

Building Parameters For Bldg-1


1 Type Rigid frame with One Modular Column – LRFM-1.
2 Width
3 Length
4 Bay spacing

5 Spacing of Interior main columns 1 @ Middle


6 Eave Clear Height
7 Roof Slope 1 : 10
Type of End Frame Both end frames are considered as Main frames & non
8
expandable.

Roof and Wall Sheeting


1 Roof Sheet As Specified.

2 Wall Cladding As Specified.

NOTE:

We have considered the following.

Above 2.6m brick wall, wall cladding considered alround the building.& above Mezzanine level Also

For Roof bracings Rod bracing with Pipe Struts considered.

For Side Wall bracings Tube bracing with Pipe Struts considered.

Building Condition – Enclosed.

Mezzanine columns up to Mezzanine level only considered.

Masonry joist considered.

1.2 Applicable Design Codes:

The Pre Engineered Building has designed according to the Buildings and Design Codes

2
1. “Code of Practice for General Construction in Steel AISC Working Stress Design &
MBMA – 2012.

2. “Code of Practice for design loads” IS: 875 (Part 3 WIND LOAD) – 2015 & MBMA
(Enclosed )”

3 Cold formed components have been designed in accordance with:


“Code of Practice for use of cold form light gauge steel structural member’s in general
building construction.” IS: 801-1975”

4 Welding has been applied in accordance with: IS : 816 Standards

5. “Criteria for Earthquake Resistant Design of Structures” IS-1893:2015 – Zone II , Factor-0.1

1.3 Design Loads:

Dead Load on roof 0.1 KN / m2 + Self weight of frame


Live Load on roof 0.57 KN / m2
Wind Speed 120 KMPH
Mezzanine Dead load 3 KN / m2
Mezzanine Live Load 5 KN / m

Earthquake Zone IS 1893-2016 Zone –II Factor-0.1.

1.4 Design Assumptions:

 The main frame rafters are rigidly connected to each other using moment type connection.
 For exterior columns, base supports considered as Fix Base
 For end wall interior columns and Main frame interior columns base supports considered as
Fix Base.
 The lateral stability of the building is provided through the frame action of the main frames.
 The longitudinal stability of the building is provided through truss action of braced bays of the
building.
 The roof purlins are continuous beams supported at rigid frame locations and span
considered as bay spacing of the building.
 The wall girts are continuous beams supported at rigid frame locations and span considered
as bay spacing of the building.
 Building enclosed condition: Enclosed.

1.5 Deflection Limitations:

Sr. Load
Deflection Structural Member Deflection Limitation
No. Combination

3
1 Main Frame Rafters

Deflection
Vertical 2 Roof Purlins

1 ith eave height Eaves Height / 100 Dead + Wind


Deflection
Lateral

2 Wall Girts Span / 120 Wind Only


3 End wall Wind Column Span / 120 Wind Only
4 Drift H/240 For Crane

Sr. Load
Deflection Structural Member Deflection Limitation
No. Combination

Span / 240 Dead + Live


1 Floor Beam
Span / 360 Live Load
Mezzanine

Deflection
Vertical

Span / 240 Dead + Live


2 Joist Beam
Span / 360 Live Load

Crane Static
Span / 600
Crane Beam

vertical load

Span / 400 Crane Lateral Load

Material Specifications:

The following is the list of the material standards and specifications for which the building components have to be
designed:

Material Specifications

Sl.
Materials Specifications Minimum Strength
No.

1 Built -up Sections-Plates IS 2062 E350 Fy = 350 N/mm2

4
2 Hot Rolled Sections Fy = 250 N/mm2

3 Bracing Rod Fy = 250 N/mm2

4 Cold Formed Sections IS 513 / IS 10748 / IS 277 Fy = 245 N/mm2

5 Roof Sheeting IS 277 – 1992 Fy = 350 N/mm2

6 Wall Sheeting IS 277 – 1992

H.S Bolts Grade 8.8


7
Machine Bolts 4.6 of IS 1364

8 Anchor Bolts Grade 36/IS 5624/IS 1367 or Equival

9 Decking Sheet IS513 / IS 14062 / IS 277