Exhibit 4.2 - UDR - Gas Scrubber Sample

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

QUALITY CONTROL MANUAL Exhibit 4.

2
SECTION VIII DIVISION I USER´S DESIGN
REV. 0
REQUIREMENTS
(SECCIÓN VIII DIV. 1 REQUISITOS DE DISEÑO DEL USUARIO) Pag. 1 of 2
Project Number:_CPM2301_
Country of Installation: Quito State/Province of Installation: City of Installation: Quito
Owner:_____CONSPECCIME__ Operator:___----____________
Quito
Liquid Level: 16"
Service:_LOW SUCTION SCRUBBER________ Item No.:_______V-2023________________
Specific Gravity: 0.53
Type:
Diameter (in.):________48" OD____________ Length, Tangent-to-Tangent:____12 ft S/S_____
Vertical Horizontal Sphere

National Board Registration Canadian Special Service: Overpressure Protection:


Required: Registration Required: Yes Lethal (L) Direct Firing (DF) Unfired Valve Rupture Disk
Yes No No Steam Boiler (UB) Other System Design
OPERATING CONDITIONS: Minimum Pressure Maximum Pressure Minimum Temperature Maximum Temperature
Case 1 30 psig 50 psig 100 °F 130 °F
Case 2 --- --- --- ---
DESIGN CONDITIONS: Pressure Temperature
Internal Design Pressure:___________________ 75 psig 175 °F
External Design Pressure:__________________ ---- ---
MAWP Internal:__________________________ Same as Design Pressure Calculated by Manufacturer:
MAWP External:_________________________ Same as Design Pressure Calculated by Manufacturer:
Minimum Design Metal Temperature (MDMT) – Case 1 Deg @ Due to: Process Other
0° F 75 psig Ambient Temperature

Minimum Design Metal Temperature (MDMT) – Case 2 Deg @ Due to: Process Other
-- --- --- Ambient Temperature

Corrosion Allowance: Shell Head Nozzles Jacket Coil Supports Internals Corrosive
Service?
Int. Ext. Int. Ext. Int. Ext. Int. Ext. Int. Ext. Int. Ext. Yes No

1/16" - 1/16" - 1/16" - - - - - - - 1/16"


Cyclic Service: Yes No -- Cycles per -- Design Life --- years Fatigue Analysis? Yes No
Wind Loading: ASCE 7 Wind Speed Classification Category Exposure Category Topographic Factor Elevation
_______IV_______
UBC IBC
115 mph _______C_________ ________1_________ _______6"________
Other None

Seismic Loading: ASCE 7 Soil Profile Classification: PWHT: Other Loadings per UG-22:
UBC IBC Per Code Temp. Gradients Deflagration
____Site Class: B
Other None Process Required
Diff. Thermal Exp.
Insulated: Yes No Type Thickness Density Coating Specification: None
By Manufacturer By Others External --------- ------- Permitted Prior to Pressure Test
Internal --------- -------
Yes No
Vessel Support: Legs Skirt Lugs Saddles Fireproofing: Type: Rating hr):
Yes No ------------------- -------------
MATERIALS
Component Specification Component Specification
Shell SA-516-70 Ellipsoidal Head SA-516-70
Hemispherical Head -- Torispherical Head -
Toriconical Head -- Conical Head -
Nozzles SA-106-B / SA-105 Flanges SA-105
Stiffener Rings - Pressure Retaining Bolts SA-193-B7 / SA-194-2H
Attachments SA-36 Internals SA-106-B / SA-36
Reinforcing Pads SA-516-70 Other Skirt SA-516-70 / ASTM A-36
NOZZLE SCHEDULE
Description Number Size Flange Class Description Number Size Flange Class
Required Type Required Type
Inlet 1 4 WNRF 150 Inspection - Handhole 2 8 WNRF 150
CPLG
Outlet 1 4 WNRF 150 Pressure Gauge 1 1 NPT 3000
CPLG
Level 2 2 WNRF 150 Temperature Gauge 1 1 NPT 3000
Drain 1 2 WNRF 150 Spare 2 2 WNRF 150
Safety 1 2 WNRF 150
QUALITY CONTROL MANUAL Exhibit 4.2
SECTION VIII DIVISION I USER´S DESIGN
REV. 0
REQUIREMENTS
(SECCIÓN VIII DIV. 1 REQUISITOS DE DISEÑO DEL USUARIO) Pag. 2 of 2

WELDED PRESSURE JOINT REQUIREMENTS


DESIGN BASIS: RT - 2 SHELL AND CONE THICKNESS BASED ON: HEAD THICKNESS BASED ON:
JOINT EFFICIENCY E = 1 JOINT EFFICIENCY E = 1

JOINT LOCATION UW-3 TYPE OF JOINT NDE WITH COMMENTS


(Use Types as Described in UW-12)

Category A
Type 1 Full - UW-11 (a)
Category B Head-to-Shell
Type 1 SPOT - UW-11(a)(5)(b)
Other: Shell to Shell Type 1 SPOT - UW-11(a)(5)(b)
Category C Body Flanges
- --
Nozzle Flanges Type 1 None UW-11(a )(4)
Category D Type 7
BODY FLANGE REQUIREMENTS
Description Type Facing/Surface Finish Gasket Style Joint Assembly (See ASME
PCC-1)

- - - - -
- - - - -
SKETCH

GENERAL NOTES

Damage Mechanism: General Corrosion Safety Relief Devices supply by others


Service Restrictions: None
CERTIFICATION
We certify that the statements made in this form are accurate and represent all details of design as per the user or his designated agent (see Nonmandatory Appendix NN)

Date:

User:_

Signed: ____
(Representative)

Registration Identification: N.A.


(Optional)
Registration Seal (Optional)

You might also like