P R O D U C T I N FO R M AT I O N
CFP Cubic
SIMPLY CONNECT AND MEASURE –
LEVEL SENSOR WITH ADDED VALUE

Level sensors
THE LEVEL SENSOR WITH ADDED VALUE:
THE CFP Cubic

One sensor – many values

Whether you’re using it for level, point level, or temperature measurement, the CFP Cubic combines a wide
variety of measurement functions into one sensor. The customizable digital and analog outputs allow you
to monitor levels and point levels in the tank. Where necessary, the IO-Link integrates the process data
into an automation network. The ample display and the teach-in buttons on the sensor head immediately
adapt the settings to the measuring task at hand. The integrated temperature sensor at the end of the
probe also determines the temperature of the measured fluid.

Thanks to intelligent technology and the integrated reference electrode, the CFP Cubic measures all media
over the entire length of the probe. The fluid is calibrated automatically using the reference electrode.

2 F l u i d s e n s o r s | SI C K 8022110/2018-04-24
Subject to change without notice
Ample display for status
and level indication

Control unit integrated right


into the sensor

5-pin and 8-pin connection,


along with IO-Link interface

Pressure compensation hole


with breathable membrane

Process connection with G ¾


and NPT ¾” screw connection
or Easy Clamp

Temperature sensor at the end


of the probe

The multifunctional sensor operates without the need for


CFP CUBIC

moving parts or filling medium calibration. It is highly resistant


to aggressive fluids. Thanks to the intuitive setup using the
guided sensor menu, it can be adapted quickly and easily to
any measuring task.

8022110/2018-04-24 F l u i d s e n s o r s | SI C K 3
Subject to change without notice
ENHANCED FLEXIBILITY WITH
CAPACITIVE LEVEL MEASUREMENT

CFP Cubic from SICK represents a profound step forward in capacitive level measurement. With just one rod probe, the sensor
reliably measures the level regardless of the material properties of the tank in question. With a system based on the specially
developed MCiM technology, SICK therefore offers an efficient alternative to conventional level measurement.

Conventional measurement method

The hitherto commonplace method of capacitive level measurement requires two electrically conductive surfaces. The electrical
field generated between the two electrodes measures the different permittivity for fluids and gases. If the fluid level increases,
the capacity changes, giving an indication of how high the tank is filled. While the tank wall and the rod probe function as elec-
trodes when used in a metal tank, a plastic tank will always require a second probe, since plastic walls do not conduct electricity.
In the conventional method of capacitive level measurement, a calibration between an empty and full tank must be performed
prior to fluids being changed.

Conventional level measurement in metal tanks... ...and in plastic tanks

Single and multiple measurements in metal tanks were previously In the previous measurement method,
carried out using the sensor rod probe and the grounded metallic two probes are required in order to carry
tank wall. out measurements in plastic tanks.

4 F l u i d s e n s o r s | SI C K 8022110/2018-04-24
Subject to change without notice
New feature: MCiM technology from SICK

With a new technology called “multi-capacitive intra-probe mea-


surement” (or MCiM for short), the CFP Cubic from SICK measures
capacity in multiple segments within the measurement probe.
Electrodes integrated into the probe make it p ­ ossible to calibrate
to the surrounding fluid. Thanks to the use of electrodes and ref-
erential return electrodes in a single rod probe, this measurement
method works independently of the tank properties and does not
require a second probe. Instead, the electrical field for the purposes
of capacity measurement is generated between the integrated elec-
trodes and through the medium being measured. This partitioned
structure of the probe allows you to perform an exact level measure-
ment along the probe regardless of the medium in question.

Advantages:
•• Measurements can be performed regardless of the tank’s shape
•• Measurements can be performed in metal and plastic tanks
without the need for a parallel probe
•• No grounding required
•• No fluid calibration required (no full or empty calibration)

Electrical field
Electrode

Return electrode

Integrated electrodes and return electrodes enable capacitive level Capacitive level measurement along the entire
measurement with just one rod probe. rod probe.

8022110/2018-04-24 F l u i d s e n s o r s | SI C K 5
Subject to change without notice
SIMPLY CONNECT AND MEASURE

CFP Cubic – one-minute installation


The CFP Cubic level sensor proves its value even before any measurements are taken: You can install the device, make any
­necessary customizations, and ensure that the sensor is fully functional all in less than a minute.

0–15 seconds

•• Mechanical installation in the tank

15–30 seconds

•• Connection to the cable

30–45 seconds

•• Definition of switching and reset points

45–60 seconds

•• Selection of required display option

6 F l u i d s e n s o r s | SI C K 8022110/2018-04-24
Subject to change without notice
Benefits at a glance
The CFP Cubic combines simple installation with high process accuracy and advanced technology.

Customized operating options

•• Manual settings available for the sensor via the guided menu or expert menu
•• Convenient teach-in and data management options from your computer thanks
to the IO-Link 1.1 interface

One sensor for level and temperature

•• Continuous level measurement


•• Point level measurement
•• Temperature measurement by means of the integrated temperature sensor at
the end of the probe

Easy installation, measurements in no time

•• No teach-in of the medium required


•• Measurement irrespective of container material
•• Measurement in oils, water-based liquids, or emulsions

Measurement in confined installation situations

•• Low dead zone


•• Variable probe length up to 1,000 mm
•• Adjustable height thanks to the Easy Clamp clamping jaws

8022110/2018-04-24 F l u i d s e n s o r s | SI C K 7
Subject to change without notice
EASY TO INSTALL
IN ALMOST ANY APPLICATION

Flexibility and process accuracy for a variety of measuring tasks

Level and temperature measurement in


hydraulic and cooling lubricant systems
Task:
Continuous level monitoring for oils and water

Special features of the product in this application:


•• Quick installation
•• No calibration with empty or full tank
•• Measurement of oils and emulsions supported
•• No calibration to the medium

Monitoring of coolants and lubricants in


machine tools
Task:
Point level measurement in CNC machines

Special features of the product in this application:


•• Resistant to metal chips

8 F l u i d s e n s o r s | SI C K 8022110/2018-04-24
Subject to change without notice
Level measurement in plastic tanks
Task:
Continuous measurement and point level monitoring for
fluids

Special features of the product in this application:


•• Short installation time
•• No accessories required
•• Not affected by the shape of the container
•• Grounding of the tank is not required

Monitoring of cleaning solutions and cleaning


agents in machine engineering
Task:
Monitoring using the sensor display and point level monitoring

Special features of the product in this application:


•• Fast commissioning
•• Measured value indicated clearly on the display
•• Low dead zone; measurement possible down to the base
of the tank

8022110/2018-04-24 F l u i d s e n s o r s | SI C K 9
Subject to change without notice
CFP Cubic Level sensors

A
SIMPLY CONNECT AND MEASURE –
B LEVEL SENSOR WITH ADDED VALUE
C Product description

D The CFP Cubic is a capacitive level


sensor for taking continuous level, limit,
and simultaneous temperature mea-
tional accessories. Medium calibration
is not necessary. The probe’s plastic sur-
face prevents deposits and ensures high

E surements. Thanks to intelligent MCiM


technology (multi-capacitive intra-probe
measuring), the CFP Cubic measures
resistance to aggressive media. The
sensor’s intuitive setup uses a guided
menu to ensure quick and easy adap-

F
media over the entire length of the tation to the measuring task. IO-Link
probe – irrespective of the container allows the process data to be integrated
material and without the need for addi- into an automation network.

At a glance
• Continuous level measurement and • Display and intuitive menu navigation

H temperature measurement as well as


level and temperature switches


No mechanical moving parts
IP67 enclosure rating and IO-Link 1.1
• Measurement irrespective of contain- • No dead zone along the measuring

I er material
• Probe from 100 mm to 1,000 mm
range

J Your benefits
• Plug and measure: reduced produc- • Flexible measurement in containers
tion downtime, as no teaching is with different materials – including

K required for the liquids


• Simple, intuitive operation thanks
plastic – without additional acces-
sories
to predefined menu navigation and • Measurement in small containers

L integrated display
• One sensor for two measuring appli-
and close to the ground possible
• Measurement in oils, water-based liq-
cations reduces installation complex- uids, or emulsions without additional

M ity and stock requirements accessories saves on purchase and


storage costs

N
O
P Additional information

Q Detailed technical data��������������������� 11


Type code������������������������������������������� 12

R
Ordering information������������������������� 13
Electrical connection��������������������������16
Dimensional drawing��������������������������16 -- www.sick.com/CFP_Cubic

S Accessories����������������������������������������17 For more information, simply enter the link or scan the QR code and get direct access to
technical data, CAD design models, operating instructions, software, application examples, and
much more.

T 10 F l u i d s e n s o r s | SI C K 8022110/2018-04-24
Subject to change without notice
Level sensors CFP Cubic

Detailed technical data


Features
A
Medium
Measurement
Water and oil-based liquids
Switch, Continuous
B
C
Probe length 100 mm ... 1,000 mm
Process pressure 0 bar relativ (atmospheric)
Process temperature –20 °C ... +80 °C
UL approval
RoHS certificate
l
l
D
IO-Link l

1)
Temperature measurement Probe tip (depending on type) 1)
Available for product variants with output signal C (4 digital outputs + 2 analog outputs).
E
Performance
Accuracy of sensor element ± 15 mm (with water or oil under reference conditions)
F
Reproducibility < 5 mm
Resolution < 2 mm
Response time < 300 ms
Dielectricity constant
Conductivity
>2
No limitation
H
I
Deactivated area at end of probe 7 mm ... 15 mm, depending on probe length
Temperature measurement
Measuring range (temperature) –20 °C ... +80 °C
Accuracy (temperature)
Resolution (temperature)
± 2 °C
≤ 0.1 °C
J
K
Response time (temperature) 120 s

Mechanics
Wetted parts
Process connection
Outer tube: polypropylene (PP-H), G 3/4” and 3/4’’ NPT: PBT, Easy Clamp Bracket: PP
Without process connection L
G¾A

Housing material
¾” NPT (depending on type)
PBT / PC M
Max. probe load ≤ 4 Nm
Probe diameter 16 mm
N
Electronics
Supply voltage
Power consumption
10 V DC ... 30 V DC 1)
≤ 100 mA at 24 V DC without output load
O
Initialization time
Protection class
≤5s
III P
Electrical connection Round connector M12 x 1, 5-pin / M12 round connector x 1, 8-pin (depending on type)
Output signal 2 x PNP/NPN/push-pull transistor outputs switchable
2 x PNP/NPN/push-pull transistor outputs switchable and 1 x analog output 4 mA ... 20 mA /
Q
0 V ... 10 V automatically switchable depending on output load or output voltage depending
on the load
4 x PNP/NPN/push-pull transistor outputs switchable and 2 x analog outputs 4 mA ... 20 mA,
0 V ... 10 V depending on output load or output voltage depending on the load (depending on
R
type)
1)
All connections are polarity protected. All outputs are overload and short-circuit protected.
S
8022110/2018-04-24
Subject to change without notice
F l u i d s e n s o r s | SI C K 11
T
CFP Cubic Level sensors

A Output load 4 mA ... 20 mA < 500 Ohm at Uv > 15 V


4 mA ... 20 mA < 350 Ohm at Uv > 12 V
0 V ... 10 V > 750 Ohm at Uv 14 ≥ V

B Hysteresis
Signal voltage HIGH
Min. 3 mm, min. 2 °C, free adjustable
Vs - 3 V

C
Signal voltage LOW ≤3V
Output current < 100 mA
Inductive load <1H

D Capacitive load
Enclosure rating
100 nF
IP65 / IP67
Temperature drift < 0.1 mm/K

E Lower signal level


Upper signal level
3.8 mA ... 4 mA
20 mA ... 20.5 mA

F
Resolution of analog output 12 bit
1)
All connections are polarity protected. All outputs are overload and short-circuit protected.

Ambient data
Ambient operating temperature –20 °C ... +60 °C

H
Ambient storage temperature –40 °C ... +80 °C

Type code

I Probe length in mm
0100 100 mm (in 100 mm stages)
1000 1,000 mm

J Probe version
P Monoprobe made of PP
Process connection
A G ¾ A made from PBT

K
B ¾” NPT made from PBT
X Without process connection
Application type
N Oil and water applications

L
Housing
N Plastic housing with display
Electrical output
A 2 digital outputs
B 2 digital outputs + 1 analog output

M C 4 digital outputs + 2 analog outputs


Optional add-on
X Without
T With temperature sensor

N
O CFP - X P N N

P Not all variants of the type code can be combined!

Q
R
S
T 12 F l u i d s e n s o r s | SI C K 8022110/2018-04-24
Subject to change without notice
Level sensors CFP Cubic

Ordering information
• Enclosure rating: IP65 / IP67
A
• Process temperature: –20 °C ... +80 °C


Process pressure: 0 bar relativ
Housing material: PBT / PC B
• Electrical connection: round connector M12 x 1, 5-pin
Process connection Output signal
2 x PNP/NPN/Push-Pull
Probe length
100 mm
Type
CFP0100-XPANNAX
Part no.
1083197
C
D
G¾A 2 x PNP/NPN/Push-Pull +
100 mm CFP0100-XPANNBX 1083216
4 mA ... 20 mA / 0 V ... 10 V
2 x PNP/NPN/Push-Pull 100 mm CFP0100-XPBNNAX 1083234
¾” NPT

E
2 x PNP/NPN/Push-Pull +
100 mm CFP0100-XPBNNBX 1083255
4 mA ... 20 mA / 0 V ... 10 V
2 x PNP/NPN/Push-Pull 100 mm CFP0100-XPXNNAX 1083100
Without process connection

F
2 x PNP/NPN/Push-Pull +
100 mm CFP0100-XPXNNBX 1083119
4 mA ... 20 mA / 0 V ... 10 V
2 x PNP/NPN/Push-Pull 200 mm CFP0200-XPANNAX 1083199
G¾A 2 x PNP/NPN/Push-Pull +
200 mm CFP0200-XPANNBX 1082626
4 mA ... 20 mA / 0 V ... 10 V
2 x PNP/NPN/Push-Pull 200 mm CFP0200-XPBNNAX 1083236
¾” NPT 2 x PNP/NPN/Push-Pull +

H
200 mm CFP0200-XPBNNBX 1083257
4 mA ... 20 mA / 0 V ... 10 V
2 x PNP/NPN/Push-Pull 200 mm CFP0200-XPXNNAX 1083102
Without process connection 2 x PNP/NPN/Push-Pull +

I
200 mm CFP0200-XPXNNBX 1083121
4 mA ... 20 mA / 0 V ... 10 V
2 x PNP/NPN/Push-Pull 300 mm CFP0300-XPANNAX 1083201
G¾A 2 x PNP/NPN/Push-Pull +
300 mm CFP0300-XPANNBX 1083219

¾” NPT
4 mA ... 20 mA / 0 V ... 10 V
2 x PNP/NPN/Push-Pull
2 x PNP/NPN/Push-Pull +
300 mm CFP0300-XPBNNAX 1083238 J
300 mm CFP0300-XPBNNBX 1083259

K
4 mA ... 20 mA / 0 V ... 10 V
2 x PNP/NPN/Push-Pull 300 mm CFP0300-XPXNNAX 1083104
Without process connection 2 x PNP/NPN/Push-Pull +
300 mm CFP0300-XPXNNBX 1083123

L
4 mA ... 20 mA / 0 V ... 10 V
2 x PNP/NPN/Push-Pull 400 mm CFP0400-XPANNAX 1083203
G¾A 2 x PNP/NPN/Push-Pull +
400 mm CFP0400-XPANNBX 1083221
4 mA ... 20 mA / 0 V ... 10 V

¾” NPT
2 x PNP/NPN/Push-Pull
2 x PNP/NPN/Push-Pull +
400 mm CFP0400-XPBNNAX 1083240
M
400 mm CFP0400-XPBNNBX 1083261
4 mA ... 20 mA / 0 V ... 10 V

Without process connection


2 x PNP/NPN/Push-Pull
2 x PNP/NPN/Push-Pull +
400 mm

400 mm
CFP0400-XPXNNAX

CFP0400-XPXNNBX
1083106

1083125
N
4 mA ... 20 mA / 0 V ... 10 V

G¾A
2 x PNP/NPN/Push-Pull
2 x PNP/NPN/Push-Pull +
500 mm

500 mm
CFP0500-XPANNAX

CFP0500-XPANNBX
1083205

1082627
O
4 mA ... 20 mA / 0 V ... 10 V

¾” NPT
2 x PNP/NPN/Push-Pull
2 x PNP/NPN/Push-Pull +
500 mm

500 mm
CFP0500-XPBNNAX

CFP0500-XPBNNBX
1083242

1083263
P
4 mA ... 20 mA / 0 V ... 10 V

Without process connection


2 x PNP/NPN/Push-Pull
2 x PNP/NPN/Push-Pull +
4 mA ... 20 mA / 0 V ... 10 V
500 mm

500 mm
CFP0500-XPXNNAX

CFP0500-XPXNNBX
1083094

1083127
Q
G¾A
2 x PNP/NPN/Push-Pull
2 x PNP/NPN/Push-Pull +
4 mA ... 20 mA / 0 V ... 10 V
600 mm

600 mm
CFP0600-XPANNAX

CFP0600-XPANNBX
1083207

1083224
R
S
8022110/2018-04-24
Subject to change without notice
F l u i d s e n s o r s | SI C K 13
T
CFP Cubic Level sensors

A Process connection Output signal


2 x PNP/NPN/Push-Pull
Probe length
600 mm
Type
CFP0600-XPBNNAX
Part no.
1083244
¾” NPT

B
2 x PNP/NPN/Push-Pull +
600 mm CFP0600-XPBNNBX 1083265
4 mA ... 20 mA / 0 V ... 10 V
2 x PNP/NPN/Push-Pull 600 mm CFP0600-XPXNNAX 1083109
Without process connection

C
2 x PNP/NPN/Push-Pull +
600 mm CFP0600-XPXNNBX 1083129
4 mA ... 20 mA / 0 V ... 10 V
2 x PNP/NPN/Push-Pull 700 mm CFP0700-XPANNAX 1083209
G¾A 2 x PNP/NPN/Push-Pull +

D
700 mm CFP0700-XPANNBX 1083226
4 mA ... 20 mA / 0 V ... 10 V
2 x PNP/NPN/Push-Pull 700 mm CFP0700-XPBNNAX 1083246
¾” NPT 2 x PNP/NPN/Push-Pull +

E
700 mm CFP0700-XPBNNBX 1083267
4 mA ... 20 mA / 0 V ... 10 V
2 x PNP/NPN/Push-Pull 700 mm CFP0700-XPXNNAX 1083111
Without process connection 2 x PNP/NPN/Push-Pull +

F
700 mm CFP0700-XPXNNBX 1083131
4 mA ... 20 mA / 0 V ... 10 V
2 x PNP/NPN/Push-Pull 800 mm CFP0800-XPANNAX 1083211
G¾A 2 x PNP/NPN/Push-Pull +
800 mm CFP0800-XPANNBX 1083228
4 mA ... 20 mA / 0 V ... 10 V
2 x PNP/NPN/Push-Pull 800 mm CFP0800-XPBNNAX 1083248
¾” NPT 2 x PNP/NPN/Push-Pull +
800 mm CFP0800-XPBNNBX 1083269

H
4 mA ... 20 mA / 0 V ... 10 V
2 x PNP/NPN/Push-Pull 800 mm CFP0800-XPXNNAX 1083113
Without process connection 2 x PNP/NPN/Push-Pull +
800 mm CFP0800-XPXNNBX 1083133

I
4 mA ... 20 mA / 0 V ... 10 V
G¾A 2 x PNP/NPN/Push-Pull 900 mm CFP0900-XPANNAX 1083213
2 x PNP/NPN/Push-Pull 900 mm CFP0900-XPBNNAX 1083250

J
¾” NPT 2 x PNP/NPN/Push-Pull +
900 mm CFP0900-XPBNNBX 1083271
4 mA ... 20 mA / 0 V ... 10 V
2 x PNP/NPN/Push-Pull 900 mm CFP0900-XPXNNAX 1083115

K
Without process connection 2 x PNP/NPN/Push-Pull +
900 mm CFP0900-XPXNNBX 1083135
4 mA ... 20 mA / 0 V ... 10 V
2 x PNP/NPN/Push-Pull 1,000 mm CFP1000-XPANNAX 1082175
G¾A

L
2 x PNP/NPN/Push-Pull +
1,000 mm CFP1000-XPANNBX 1083232
4 mA ... 20 mA / 0 V ... 10 V
2 x PNP/NPN/Push-Pull 1,000 mm CFP1000-XPBNNAX 1083252
¾” NPT 2 x PNP/NPN/Push-Pull +

M Without process connection


4 mA ... 20 mA / 0 V ... 10 V

2 x PNP/NPN/Push-Pull
1,000 mm

1,000 mm
CFP1000-XPBNNBX

CFP1000-XPXNNAX
1083253

1083117
CFP1000-XPXNNBX 1083095

N
O
P
Q
R
S
T 14 F l u i d s e n s o r s | SI C K 8022110/2018-04-24
Subject to change without notice
Level sensors CFP Cubic




Enclosure rating: IP65 / IP67
Output signal: 4 x PNP/NPN/Push-Pull + 2 x 4 mA ... 20 mA / 0 V ... 10 V
Process temperature: –20 °C ... +80 °C
A
B
• Process pressure: 0 bar relativ
• Housing material: PBT / PC
• Electrical connection: M12 round connector x 1, 8-pin
• Temperature measurement: l

Process connection Probe length Type Part no.


C
D
G¾A 100 mm CFP0100-XPANNCT 1090856
¾” NPT 100 mm CFP0100-XPBNNCT 1090865
G¾A 200 mm CFP0200-XPANNCT 1090858
¾” NPT
G¾A
200 mm
300 mm
CFP0200-XPBNNCT
CFP0300-XPANNCT
1090867
1090859
E
¾” NPT 300 mm CFP0300-XPBNNCT 1090869
G¾A
¾” NPT
400 mm
400 mm
CFP0400-XPANNCT
CFP0400-XPBNNCT
1090861
1090871
F
G¾A 500 mm CFP0500-XPANNCT 1079837
¾” NPT 500 mm CFP0500-XPBNNCT 1080913
G¾A 600 mm CFP0600-XPANNCT 1090862
¾” NPT
G¾A
600 mm
700 mm
CFP0600-XPBNNCT
CFP0700-XPANNCT
1090873
1085460
H
I
¾” NPT 700 mm CFP0700-XPBNNCT 1090874
G¾A 800 mm CFP0800-XPANNCT 1090863
¾” NPT 800 mm CFP0800-XPBNNCT 1090875
G¾A
¾” NPT
900 mm
900 mm
CFP0900-XPANNCT
CFP0900-XPBNNCT
1090864
1090876
J
G¾A 1,000 mm CFP1000-XPANNCT 1079839
¾” NPT 1,000 mm CFP1000-XPBNNCT 1080914 K
L
M
N
O
P
Q
R
S
8022110/2018-04-24
Subject to change without notice
F l u i d s e n s o r s | SI C K 15
T
CFP Cubic Level sensors

A Electrical connection

B
C
 


   
D

 
 

E
1 L+: Supply voltage 1 L+: Supply voltage

F 2 QA: Analog current-/voltage output


3 M: Ground, reference ground for current-/voltage output
4 C/Q1: Switching output 2, PNP/NPN/DRV (Push-Pull) / IO-Link
2 Q2: Switching output 2, PNP/NPN/DRV (Push-Pull)
3 M: Ground, reference ground for current-/voltage output
4 C/Q1: Switching output 2, PNP/NPN/DRV (Push-Pull) / IO-Link
5 Q2: Switching output 2, PNP/NPN/DRV (Push-Pull) 5 Q3: Switching output 3, PNP/NPN/DRV (Push-Pull)
6 Q4: Switching output 4, PNP/NPN/DRV (Push-Pull)
7 QA: Analog current-/voltage output
8 Q B: Analog current-/voltage output

H Dimensional drawing


I 
00HDVXULQJUDQJH
/3UREHOHQJWK
,$(,QDFWLYHDUHDDW

J

SUREHHQG






K



0[



L  



*$
137

M
N
0
/



O 

7HPSHUDWXUHVHQVRU

P RSWLRQDO
,$(

Q
R
S
T 16 F l u i d s e n s o r s | SI C K 8022110/2018-04-24
Subject to change without notice
Level sensors CFP Cubic

Accessories
Mounting systems
A
Terminal and alignment brackets
Terminal brackets
B
Brief description
Easy-clamp bracket for variable probe fastening, without mounting hardware (essential for CFP variants
Type
BEF-FL-PRBCFP-
Part no.

2087299
C
without process connection) HLDR

Connection systems D
Modules and gateways
Fieldbus modules E
Brief description Type Part no.

F
EtherCAT IO-Link Master, IO-Link V1.1, Port Class A, power supply via 7/8’’ cable 24 V / IOLG2EC-03208R01
6053254
8 A, fieldbus connection via M12 cable (IO-Link Master)
Illustration may
differ

EtherNet/IP IO-Link Master, IO-Link V1.1, Port Class A, power supply via 7/8’’ cable
24 V / 8 A, fieldbus connection via M12-cable
IOLG2EI-03208R01
(IO-Link Master)
6053255 H
Illustration may
differ

PROFINET IO-Link Master, IO-Link V1.1, Port Class A, power supply via 7/8’’ cable 24 V IOLG2PN-03208R01
6053253
I
/ 8 A, fieldbus connection via M12 cable (IO-Link Master)

Plug connectors and cables


J
K
Connecting cables with female connector

Brief description Cable length Type Part no.

Head A: female connector, M12, 5-pin,


straight
Head B: open cable ends
2m DOL-1205-G02M 6008899
L
Illustration may Cable: PVC, unshielded, 5.7 mm
differ
Head A: female connector, M12, 5-pin,
straight
M
N
Head B: open cable ends 2m DOL-1205-G02MC 6025906
Cable: Power, I/O, PUR, halogen-free,
unshielded, 5 mm

O
Head A: female connector, M12, 5-pin,
straight
5m DOL-1205-G05M 6009868
Head B: open cable ends
Illustration may Cable: PVC, unshielded, 5.7 mm

P
differ
Head A: female connector, M12, 5-pin,
straight
Head B: open cable ends 5m DOL-1205-G05MC 6025907
Cable: PUR, halogen-free, unshielded,
5 mm Q
Head A: female connector, M12, 5-pin,
straight
Head B: open cable ends
Illustration may Cable: PVC, unshielded, 5.7 mm
10 m DOL-1205-G10M 6010544 R
S
differ

8022110/2018-04-24
Subject to change without notice
F l u i d s e n s o r s | SI C K 17
T
CFP Cubic Level sensors

A Brief description
Head A: female connector, M12, 5-pin,
Cable length Type Part no.

straight

B Head B: open cable ends


Cable: PUR, halogen-free, unshielded,
5 mm
10 m DOL-1205-G10MC 6025908

C Head A: female connector, M12, 5-pin,


angled
Head B: open cable ends
2m DOL-1205-W02M 6008900

D
Illustration may Cable: PVC, unshielded, 5.7 mm
differ
Head A: female connector, M12, 5-pin,
angled

E
Head B: open cable ends 2m DOL-1205-W02MC 6025909
Cable: Power, I/O, PUR, halogen-free,
unshielded, 5 mm

F Head A: female connector, M12, 5-pin,


angled
Head B: open cable ends
5m DOL-1205-W05M 6009869
Illustration may Cable: PVC, unshielded, 5.7 mm
differ
Head A: female connector, M12, 5-pin,
angled
Head B: open cable ends 5m DOL-1205-W05MC 6025910

H Cable: PUR, halogen-free, unshielded,


5 mm

I
Head A: female connector, M12, 5-pin,
angled
10 m DOL-1205-W10M 6010542
Head B: open cable ends
Illustration may Cable: PVC, unshielded, 5.7 mm

J
differ
Head A: female connector, M12, 5-pin,
angled
Head B: open cable ends 10 m DOL-1205-W10MC 6025911

K Cable: PUR, halogen-free, unshielded,


5 mm
Head A: female connector, M12, 8-pin,
straight

L
2m DOL-1208-G02MA 6020633
Head B: open cable ends
Cable: PVC, shielded, 7.7 mm
Head A: female connector, M12, 8-pin,

M
straight
Head B: open cable ends 2m DOL-1208-G02MC 6035620
Cable: PUR, halogen-free, unshielded,
5.9 mm

N Head A: female connector, M12, 8-pin,


straight
Head B: open cable ends
5m DOL-1208-G05MA 6020993
Cable: PVC, shielded, 7.7 mm

O Head A: female connector, M12, 8-pin,


straight
Head B: open cable ends 5m
DOL-1208-G05MAC-
6054489
RO

P
Cable: PUR, halogen-free, shielded,
6.3 mm
Head A: female connector, M12, 8-pin,
straight

Q Head B: open cable ends


Cable: PUR, halogen-free, unshielded,
5.9 mm
5m DOL-1208-G05MC 6035621

Head A: female connector, M12, 8-pin,

R straight
Head B: open cable ends
Cable: PVC, shielded, 7.7 mm
10 m DOL-1208-G10MA 6022152

S
T 18 F l u i d s e n s o r s | SI C K 8022110/2018-04-24
Subject to change without notice
Level sensors CFP Cubic

Brief description
Head A: female connector, M12, 8-pin,
Cable length Type Part no.
A
straight

B
DOL-1208-G10MAC-
Head B: open cable ends 10 m 6054488
RO
Cable: PUR, halogen-free, shielded,
6.3 mm

C
Head A: female connector, M12, 8-pin,
straight
Head B: open cable ends 10 m DOL-1208-G10MC 6035622
Cable: PUR, halogen-free, unshielded,

D
5.9 mm
Head A: female connector, M12, 8-pin,
straight
DOL-1208-G20MAC-
Head B: open cable ends 20 m 6050686

E
RO
Cable: PUR, halogen-free, shielded,
6.3 mm
Head A: female connector, M12, 8-pin,

F
angled
2m DOL-1208-W02MA 6020992
Head B: open cable ends
Cable: PVC, shielded, Ø 7.7 mm
Head A: female connector, M12, 8-pin,
angled
2m DOL-1208-W02MC 6035623
Head B: open cable ends
Cable: PUR, unshielded, 5.9 mm
Head A: female connector, M12, 8-pin,
angled
Head B: open cable ends
Cable: PVC, shielded, Ø 7.7 mm
5m DOL-1208-W05MA 6021033
H
I
Head A: female connector, M12, 8-pin, 5m DOL-1208-W05MC 6035624
angled
Head B: open cable ends 10 m DOL-1208-W10MC 6035625
Cable: PUR, unshielded, 5.9 mm

J
REGISTER AT WWW.SICK.COM TO TAKE ADVANTAGE
K
OF OUR FOLLOWING SERVICES FOR YOU L
m
m
Access information on net prices and individual discounts.
Easily order online and track your delivery.
M
m
m
Check your history of all your orders and quotes.
Create, save, and share as many wish lists as you want. N
O
m Use the direct order to quickly order a big amount of
products.
m Check the status of your orders and quotes and get infor-

m
mation on status changes by e-mail.
Save time by using past orders. P
m Easily export orders and quotes, suited to your systems.
Q
R
S
8022110/2018-04-24
Subject to change without notice
F l u i d s e n s o r s | SI C K 19
T
SICK AT A GLANCE
8022110/2018-04-24 ∙ 9PMS ∙ Pre USmod en47

SICK is a leading manufacturer of intelligent sensors and sensor solutions for industrial applications. With
more than 8,000 employees and over 50 subsidiaries and equity investments as well as numerous agencies
worldwide, we are always close to our customers. A unique range of products and services creates the
perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and
preventing damage to the environment.

We have extensive experience in various industries and understand their processes and requirements.
With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe,
Asia and North America, system solutions are tested and optimized in accordance with customer specifica-
tions. All this makes us a reliable supplier and development partner.

Comprehensive services round out our offering: SICK LifeTime Services provide support throughout the
machine life cycle and ensure safety and productivity.

For us, that is “Sensor Intelligence.”

Worldwide presence:

Australia, Austria, Belgium, Brazil, Canada, Chile, China, Czech Republic, Denmark, Finland, France,
Germany, Great Britain, Hungary, Hong Kong, India, Israel, Italy, Japan, Malaysia, Mexico, Netherlands,
New Zealand, Norway, Poland, Romania, Russia, Singapore, Slovakia, Slovenia, South Africa, South Korea,
Spain, Sweden, Switzerland, Taiwan, Thailand, Turkey, United Arab Emirates, USA, Vietnam.

Detailed addresses and further locations - www.sick.com

SICK AG | Waldkirch | Germany | www.sick.com


P R O D U C T I N FO R M AT I O N
MHF15
SIMPLE, COMPACT AND ROBUST

Level sensors
MHF15 LEVEL Sensors

SIMPLE, COMPACT AND ROBUST

Product description
The MHF15 is a compact optical level rated housing, provides reliability not
limit switch that is easy to commission. only on the process side, but also in situ-
The sensor is based on SICK’s energetic ations where there are adverse ambient
photoelectric proximity sensor technolo- conditions outside the tank. In addition,
gy, which has been tested and optimized fast, hassle-free commissioning does
over a number of decades. This sensor not require medium calibration, reducing
has a simple, robust and reliable con- commissioning costs and maintenance.
struction. The use of high-quality materi- The optical technology makes the
als, such as stainless steel 1.4404 and MHF15 particularly well-suited to use
polysulfone, combined with the IP 69K- with water-based media.

At a glance
• Robust level monitoring in liquid with- • Process connection G ½
out additional requirements • Highly medium resistant due to
• Small, compact design; no medium stainless steel housing 1.4404, poly-
calibration required sulfone apex
• Process temperature up to 55 °C, • Output available as PNP or NPN
process pressure up to 16 bar transistor
• IP 67 and IP 69K enclosure rating • FDA-compliant, UL

Your benefits
• Small, compact sensor ideal for • No moving mechanical parts reduce
difficult installation conditions with maintenance and eliminate the need
limited space to recalibrate -- even after long peri-
• Quick commissioning without ods of use.
medium calibration saves time and
money

Additional information
Detailed technical data������������������������3
Type code����������������������������������������������4
Ordering information����������������������������4
Dimensional drawing����������������������������4
Application information������������������������5 -- www.mysick.com/en/MHF15
For more information, just enter the link or scan the QR code and get direct access to technical
Recommended accessories����������������6
data, CAD design models, operating instructions, software, application examples and much
more.

2 F l u i d S e n s o r s | S I C K 8013868/2015-03-26
Subject to change without notice
LEVEL Sensors MHF15

Detailed technical data


Features
Medium Fluids
Measurement Switch
Light source LED
Type of light Visible red light
Wave length 650 nm
Process pressure –0.5 bar ... 16 bar
Process temperature –25 °C ... +55 °C
GOST approval l
UL approval l
RoHS certificate l

Performance
Response time 2 ms

Mechanics
Wetted parts Stainless steel 316L, polysulfon, FPM
Process connection G½
Housing material Stainless steel 1.4404

Electronics
Supply voltage 10 V DC ... 30 V DC 1)
Residual ripple ≤ 5 Vpp 2)
Power consumption ≤ 30 mA at 24 V DC without output load
Protection class III
Electrical connection Round connector M12 x 1, 4-pin
Output signal 1x PNP 3)
1x NPN 3)
(depending on type)
Switching mode Normally closed / Normally open (depending on type)
Signal voltage HIGH Vs - 2.9 V
Signal voltage LOW Approx. 0 V (PNP)
≤ 2,9 V (NPN)
Output current ≤ 100 mA 3)
Switching frequency 250 Hz 4)
Enclosure rating IP 67: EN 60529, IP 69K: EN 40050
1)
VS connections reverse-polarity protected.
2)
May not exceed or fall below Uv tolerances.
3)
Output overcurrent and short-circuit protected.
4)
With light/dark ratio 1:1.

Ambient data
Ambient operating temperature –25 °C ... +55 °C
Ambient storage temperature –25 °C ... +70 °C

8013868/2015-03-26 F l u i d S e n s o r s | S I C K 3
Subject to change without notice
MHF15 LEVEL Sensors

Type code

Switch output
P 1 x PNP transistor output, normally closed
N 1 x NPN transistor output, normally closed
H 1 x PNP transistor output, normally open
T 1 x NPN transistor output, normally open

MHF15 - 2 1 N G 1 S M

Ordering information
• Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050
• Process connection: G ½
• Process temperature: –25 °C ... +55 °C
• Process pressure: –0.5 bar ... 16 bar
• Housing material: Stainless steel 1.4404
• Electrical connection: round connector M12 x 1, 4-pin
Output signal Switching mode Model name Part no.
1x PNP Normally open MHF15-21NG1HSM 1052273
1x NPN Normally closed MHF15-21NG1NSM 1052272
1x PNP Normally closed MHF15-21NG1PSM 1052237
1x NPN Normally open MHF15-21NG1TSM 1052274

Dimensional drawing (Dimensions in mm (inch))


MHF15
63.6
(2.50)
26.7
(1.05)
19
9.1
(0.36) (0.75)
M12x1

G 1/2

32 O-Ring 22 x 2,5
(1.26)
(O-Ring 0.87 x 0.10)

Connection type and diagram


Connector M12x1, 4-pin

brn 1
L+
blu 3
M
blk 4
Q
wht 2
NC

4 F l u i d S e n s o r s | S I C K 8013868/2015-03-26
Subject to change without notice
LEVEL Sensors MHF15

Application information

Use in tanks (side mounting)


The distance A ≥ 40mm (1.57).
Sensor prism B = 8 mm (0.31).
B
The conical prism is to project into the container.

A B

A
B
B

Installation in a pipe for dry running protection. A ≥ 40 mm (1.57)

Note: A
Strong surface-forming liquids can lead to deposits on the sensor and affect the function.
Applications with foam:
•• Foam with low density can´t be detected by MHF15.
•• Foam with high density can be detected by MHF15 and can lead to faulty operation.

8013868/2015-03-26 F l u i d S e n s o r s | S I C K 5
Subject to change without notice
MHF15 LEVEL Sensors

Recommended accessories
Flanges
Brief description Type Part no.
Welded flange G1/2 BEF-FL-316G12-LMH1 4065669

Plug connectors and cables


Brief description Model name Part No.
Cable, M12, 4-pin, straight connector female with molded cable, 2 m, PVC DOL-1204-G02M 6009382
Cable, M12, 4-pin, straight connector female with molded cable, 2 m, PUR halogen free DOL-1204-G02MC 6025900
Cable, M12, 4-pin, straight connector female with molded cable, 5 m, PVC DOL-1204-G05M 6009866
Cable, M12, 4-pin, straight connector female with molded cable, 5 m, PUR halogen free DOL-1204-G05MC 6025901
Cable, M12, 4-pin, straight connector female with molded cable, 10 m, PVC DOL-1204-G10M 6010543
Cable, M12, 4-pin, straight connector female with molded cable, 10 m, PUR halogen free DOL-1204-G10MC 6025902
Cable, M12, 4-pin, straight connector female with molded cable, 15 m, PVC DOL-1204-G15M 6010753
Cable, M12, 4-pin, angled connector female with molded cable, 2 m, PVC DOL-1204-W02M 6009383
Cable, M12, 4-pin, angled connector female with molded cable, 2 m, PUR halogen free DOL-1204-W02MC 6025903
Cable, M12, 4-pin, angled connector female with molded cable, 5 m, PVC DOL-1204-W05M 6009867
Cable, M12, 4-pin, angled connector female with molded cable, 5 m, PUR halogen free DOL-1204-W05MC 6025904
Cable, M12, 4-pin, angled connector female with molded cable, 5 m, PUR halogen free, irradiated DOL-1204-W05MD 6020399
Cable, M12, 4-pin, angled connector female with molded cable, 10 m, PVC DOL-1204-W10M 6010541
Cable, M12, 4-pin, angled connector female with molded cable, 10 m, PUR halogen free DOL-1204-W10MC 6025905
SERVICES

WWW.MYSICK.COM – SEARCH ONLINE AND ORDER


Search online quickly and safely – with the SICK “Finders” Efficiency – with the e-commerce tools from SICK

Product
Applications
Literature
Service
Accessories
Software

Product Finder: We can help you to quickly target the product Find out prices and availability: Determine the price and
that best matches your application. possible delivery date of your desired product simply and
quickly at any time.
Applications Finder: Select the application description on
the basis of the challenge posed, industrial sector, or product Request or view a quote: You can have a quote generated
group. online here. Every quote is confirmed to you via e-mail.

Literature Finder: Go directly to the operating instructions, Order online: You can go through the ordering process in just
technical information, and other literature on all aspects of a few steps.
products from SICK.

These and other “Finders” at - www.mysick.com

SERVICES FOR MACHINES AND SYSTEMS: SICK LifeTime Services


Our comprehensive and versatile LifeTime Services are the perfect addition to the comprehensive range of products from
SICK. The services range from product-independent consulting to traditional product services.

Consulting & Design


Safe and professional

Product & System Support


Reliable, fast and on-site

Verification & Optimization


Safe and regularly inspected

Upgrade & Retrofits


Easy, safe, economical

Training & Education


Practical, focused and professional
SICK AT A GLANCE
8013868/2015-03-26 ∙ 9MS ∙ Pre USmod en43

SICK is a leading manufacturer of intelligent sensors and sensor solutions for industrial applications. With
more than 6,500 employees and over 50 subsidiaries and equity investments as well as numerous repre-
sentative offices worldwide, we are always close to our customers. A unique range of products and services
creates the perfect basis for controlling processes securely and efficiently, protecting individuals from ac-
cidents and preventing damage to the environment.

We have extensive experience in various industries and understand their processes and requirements.
With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe,
Asia and North America, system solutions are tested and optimized in accordance with customer specifica-
tions. All this makes us a reliable supplier and development partner.

Comprehensive services round out our offering: SICK LifeTime Services provide support throughout the
machine life cycle and ensure safety and productivity.

For us, that is “Sensor Intelligence.”

Worldwide presence:
Australia, Austria, Belgium/Luxembourg, Brazil, Czech Republic, Canada, China, Denmark, Finland, France,
Germany, Great Britain, Hungary, India, Israel, Italy, Japan, Mexico, Netherlands, Norway, Poland, Romania,
Russia, Singapore, Slovenia, South Africa, South Korea, Spain, Sweden, Switzerland, Taiwan, Turkey, United
Arab Emirates, USA
Detailed addresses and additional representatives - www.sick.com

SICK AG | Waldkirch | Germany | www.sick.com


P R O D U C T I N F O R M AT I O N
LFP Inox AND LFP Cubic
FLEXIBLE UP TO THE PROBE TIP

Level sensors
A solution for every application
Whether it is continuous level measurement, point level measurement or a combination of the two, SICK provides a wide range of
solutions for process control, storage, and protection. SICK always has the ideal sensor, suited to any installation situation and a
wide range of liquids and measurement environments, and always has the same goal in mind – to enable efficient processes. SICK
makes the most of the knowledge it has amassed as the supplier of one of the most comprehensive technology portfolios in this
sector, enabling the company to integrate its sensors and systems seamlessly into overall systems.

With its LFP Cubic and LFP Inox level sensors, SICK offers solutions for any application, in any setting.

PWIS-
cleaned

2 LEVEL SENSORS | SICK 8017952/2015-05-02


Subject to change without notice
LEVEL MEASUREMENT IN ANY SETTING:
LFP Inox AND LFP Cubic

Reliable and flexible technology

LFP Cubic and LFP Inox are based on time-domain reflectometry (TDR), which enables the sensors to be used universally, no
matter what the installation situation, container size or measured medium. This method provides the highest level of reliability and
produces the most accurate measurement results.

The perfect portfolio for any application

With the LFP Cubic and LFP Inox, SICK offers solutions for a wide range of applications: the portfolio features level sensors that are
suitable for use in mechanical engineering as well as in the food, beverage and pharmaceutical industries. SICK provides the right
solution for every application with different probe lengths and types: this saves space and money.

LFP Inox LFP Cubic

Hygiene applications (sensors can be used in CIP and SIP processes) l

EHEDG certification l

Foam applications l l

Rod probe up to 2 m long l l

Rod probe up to 4 m long l

Cable probe up to 4 m long l

Separate electronics housing l l

Analog output and two switching outputs l l

Analog output and four switching outputs l l

WHG (German Water Management Act) certification l

IO-Link communication l l

Compact variant (without probe) l

Wetted parts made from titanium (without probe) l

8017952/2015-05-02 LEVEL SENSORS | SICK 3


Subject to change without notice
LFP Inox: THE CLEAN SOLUTION

The materials used in the LFP Inox meet FDA requirements and the whole sensor is EHEDG certified, meaning that the sensor ful-
fills the most stringent of hygiene requirements. The sensor's temperature and pressure resistance mean it can be used in CIP and
SIP processes without any restrictions.

The LFP Inox is a reliable solution from SICK with an outstanding price-performance ratio.

Hygienic design

• Replaceable hygienic process connections


• CIP and SIP resistant
• Rod probe with a surface roughness smaller than 0.8 µm

Remote amplifier

• Autoclavable – probe can be sterilized easily


• Probe suitable for use at high process temperatures
Space-saving solution when installation space is tight
• Electronics protected from process heat

Rugged design

• Easy to clean the sensor thoroughly


• Enclosure ratings IP 67 and IP 69K allow intensive cleaning of the sensor
using pressure washers
• Housing: stainless steel 1.4305 and 1.4404

LFP Inox tolerant of foam and film

• Ignores foam when measuring in liquids such as milk or cleaning agents

4 LEVEL SENSORS | SICK 8017952/2015-05-02


Subject to change without notice
Applications

Detecting the level in filling machine buffer tanks

Industry segment:
• Primarily the beverage industry
• Milk production

Task:
• Continuous monitoring of the fill level

Special features of the product within the application:


• Foam algorithm
• Quick response time
• Probe up to 4 m long

Monitoring the level in CIP and SIP systems within the pharmaceutical industry

Industry segment:
• Primarily in pharmaceuticals and cosmetics industries
• CIP and SIP systems

Tasks:
• Continuous monitoring of the fill level

Special features of the product within the application:


• Polished probe surface
• High-grade stainless steel for machine resistance
• Aseptic design

8017952/2015-05-02 LEVEL SENSORS | SICK 5


Subject to change without notice
LFP Cubic: A FLEXIBLE,
COST-EFFECTIVE SOLUTION

Almost entirely wear and maintenance-free, the LFP Cubic enables continuous level measurement and point level measurement to
be performed with one and the same device. It is ideally suited to use in metal containers and tanks within the water industry, in
mechanical engineering, in machine tool, in plant construction and in building technology.

Design of probe

• Rod probe, 2 m or 4 m long, which can be replaced and shortened


• Coaxial tube up to 2 m long
• Cable probe up to 4 m long
• Compact variant (without probe)

Remote amplifier

• Space-saving solution when installation space is tight


• Electronics protected from process heat

One sensor for measuring the point level and continuous level

• High-visibility display
• Two switching outputs (power and voltage signal) and 1 analog output
• Four switching outputs (power and voltage signal) and 1 analog output

LFP Cubic tolerant of foam and film

• Provides accurate measurements, even in liquids that foam and form a film

6 LEVEL SENSORS | SICK 8017952/2015-05-02


Subject to change without notice
Applications

Monitoring the fill level of water and chemicals in cleaning systems

Industry segment:
• Mechanical engineering
• Electroplating industry
• Steel production

Tasks:
• Continuous measuring
• Monitoring the point level of liquids

Special features of the product within the application:


• Four limit points detection
• Foam algorithm
• High-grade stainless steel

Monitoring lubricants and hydraulic oils in CNC machines

Industry segment:
• Machine tool engineering
• Automotive and parts supplier industries
• Hydraulics industry

Tasks:
• Monitoring via the sensor display
• Monitoring the point level

Special features of the product within the application:


• Fast commissioning
• Coaxial tube for oil applications
• Clear indication of measured values on the display

8017952/2015-05-02 LEVEL SENSORS | SICK 7


Subject to change without notice
LFP Inox Level sensors

A
B THE CLEAN SOLUTION
C Product description

D The LFP Inox is a hygienic level sensor


for liquids using TDR technology – a
process for determining the time of flight
and unrestricted cleaning, even in appli-
cations with the most stringent hygiene
requirements. Its modular connection

E of electromagnetic waves. The time


difference between the sent pulse and
the reflected pulse is used to generate a
system allows simple and flexible instal-
lation in any application. Thanks to high
temperature and pressure resistance,

F
level signal, both as a continuous value unrestricted use is possible under
(analog output) and a freely positionable CIP and SIP conditions. This impressive
switching point (switching output). The profile is topped off with communication
use of FDA-compliant materials in an capability via IO-Link to the superordi-
EHEDG-certified design means that the nate control units.
LFP Inox can be relied upon for optimum

H At a glance
• Level measurement in hygienic ap- • High enclosure rating: IP67 and

I plications
• Manually retractable monoprobe up
to 4,000 mm long with Ra ≤ 0.8 µm
IP69K, autoclavable
• Interchangeable hygienic process
connections

J • Process temperature up to 180 °C,


process pressure up to 16 bar
• CIP/SIP-resistant
• 3-in-1: combined display, analog
output, and binary output
• Remote amplifier with process con-

K nection

Your benefits

L • Robust design increases service life


• High flexibility due to cutable probe
• Time and cost savings due to low
maintenance without any calibration
and interchangeable connection and quick commissioning Remote

M concept
• Cost savings due to multiple output
display of the measured value and
space savings
signals: one system for both level

N detection and continuous level moni-


toring

O
P Additional information

Q Detailed technical data������������������������9


Ordering information��������������������������10

R
Type code������������������������������������������� 15
Dimensional drawings������������������������16
Connection type��������������������������������� 18 -- www.sick.com/LFP_Inox

S Accessories��������������������������������������� 18 For more information, simply enter the link or scan the QR code and get direct access to techni-
cal data, CAD design models, operating instructions, software, application examples, and much
more.

T 8 F l u i d s e n s o r s | SI C K 8017952/2016-05-02
Subject to change without notice
Level sensors LFP Inox

Detailed technical data


Features
A
Medium
Measurement
Fluids
Switch, continuous
B
C
Design Standard
Remote amplifier, length of cable 1 m
Remote amplifier, length of cable 2 m
Remote amplifier, length of cable 3.3 m (depending on type)
Probe length
Process pressure
200 mm ... 4,000 mm
–1 bar ... +16 bar
D
E
Process temperature –20 °C ... +180 °C (depending on type)
GOST approval l
UL approval l
RoHS certificate
IO-Link
l
l
F
EHEDG approval l
3-A – / l (depending on type)
PWIS-cleaned – / l (depending on type)

Performance H
Accuracy of sensor element ± 5 mm 1)

Repeatability
Resolution
≤ 2 mm
< 2 mm
I
J
Response time < 400 ms 2)
Dielectricity constant ≥ 5 for mono probe
≥ 1.8 with coaxial probe

K
Conductivity No limitation
Deactivated area at end of probe 10 mm 3)
MTTF 194.3 years (EN ISO 13849-1)
1)

2)

3)
For details see accuracy diagram in the operating instructions LFP Inox.
Dependent on measuring mode (high speed < 400 ms, high accuracy < 2,800 ms).
With water under reference conditions.
L
Mechanics M
Wetted parts 316L (Ra ≤ 0,8 µm), PEEK
Process connection G ¾ A / ¾” NPT,
G ¾ (hygienic process connectors with adapter for G ¾, see accessories) N
Housing material 303
Housing design
Max.probe load
With viewing panel made from PMMA (acrylic glass) / with closed cover (depending on type)
≤ 6 Nm
O
P
Material coaxial cable FEP
Length coaxial cable 1 m ... 3.3 m (depending on type)
Electrical cable insulation PVC (depending on type)

Electronics Q
Supply voltage 12 V DC ... 30 V DC 1)
Power consumption
Initialization time
≤ 75 mA at 24 V DC without output load
≤2s
R
S
1)
All connections are polarity protected. All outputs are overload and short-circuit protected.

8017952/2016-05-02
Subject to change without notice
F l u i d s e n s o r s | SI C K 9
T
LFP Inox Level sensors

A Protection class
Electrical connection
III
Round connector M12 x 1, 5-pin
Round connector M12 x 1, 8-pin

B Cable connector M12 x 1, 5-polig


Cable connector M12 x 1, 8-polig (depending on type)
Output signal 4 mA ... 20 mA, 0 V ... 10 V automatic switching depending on the load,

C 1 PNP transistor output (Q1) and 1 PNP/NPN transistor output (Q2) switchable, or
1 PNP transistor output (Q1) and 3 PNP/NPN transistor outputs (Q2 ... Q4) switchable
(depending on type) 1)

D Output load 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V


4 mA ... 20 mA < 400 Ohm at Uv > 12 V
0 V ... 10 V > 750 Ohm at Uv 14 ≥ V

E Hysteresis
Signal voltage HIGH
Min. 2 mm, free adjustable
Vs - 2 V
Signal voltage LOW ≤2V

F Output current
Inductive load
< 100 mA
<1H
Capacitive load 100 nF
Enclosure rating IP 67: EN 60529, IP 69K: EN 40050
Temperature drift < 0.1 mm/K

H Lower signal level


Upper signal level
3.8 mA ... 4 mA
20 mA ... 20.5 mA
All connections are polarity protected. All outputs are overload and short-circuit protected.

I
1)

Ambient data

J Ambient operating temperature


Ambient storage temperature
–20 °C ... +60 °C
–40 °C ... +80 °C
Ambient temperature coaxial cable –20 °C ... +60 °C

K Outdoor use Only with weather protection cover

L Ordering information
Standard amplifier

M
• Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050
• Output signal: 1 x PNP + 1 x PNP/NPN + 4 mA ... 20 mA / 0 V ... 10 V
• Process temperature: –20 °C ... +150 °C
• Process pressure: –1 bar ... 16 bar
N •

Housing material: 303
Electrical connection: round connector M12 x 1, 5-pin

O
Process connection Housing design Probe length Type Part no.

With viewing panel made from PMMA 200 mm LFP0200-G1NMB 1060307


(acrylic glass) 300 mm LFP0300-G1NMB 1053288

P
G¾A
LFP0300-G2NMB 1056287
With closed cover 300 mm
LFP0300-G3NMB 1058574

Q
¾” NPT With viewing panel made from PMMA 300 mm LFP0300-N1NMB 1056927
(acrylic glass) 400 mm LFP0400-G1NMB 1052069
With closed cover 400 mm LFP0400-G2NMB 1056225

R
G¾A With viewing panel made from PMMA
500 mm LFP0500-G1NMB 1052070
(acrylic glass)
With closed cover 500 mm LFP0500-G2NMB 1056288

S
T 10 F l u i d s e n s o r s | SI C K 8017952/2016-05-02
Subject to change without notice
Level sensors LFP Inox

Process connection
¾” NPT
Housing design

With viewing panel made from PMMA


Probe length
500 mm
Type
LFP0500-N1NMB
Part no.
1058043
A
B
(acrylic glass) 600 mm LFP0600-G1NMB 1052071
G¾A
With closed cover 600 mm LFP0600-G2NMB 1056289
¾” NPT With viewing panel made from PMMA 600 mm LFP0600-N1NMB 1059412

G¾A
(acrylic glass)

With closed cover


700 mm
700 mm
LFP0700-G1NMB
LFP0700-G2NMB
1052072
1056290
C
D
¾” NPT With viewing panel made from PMMA 700 mm LFP0700-N1NMB 1059413
(acrylic glass) 800 mm LFP0800-G1NMB 1052073
G¾A
With closed cover 800 mm LFP0800-G2NMB 1056291
¾” NPT

G¾A
With viewing panel made from PMMA
(acrylic glass)
800 mm
900 mm
LFP0800-N1NMB
LFP0900-G1NMB
1059414
1052074 E
With closed cover 900 mm LFP0900-G2NMB 1056292
¾” NPT
With viewing panel made from PMMA
900 mm LFP0900-N1NMB
LFP1000-G1NMB
1059415
1052075
F
(acrylic glass) 1,000 mm
G¾A LFP1000-G1NMBL 1073551
With closed cover 1,000 mm LFP1000-G2NMB 1056204
¾” NPT With viewing panel made from PMMA 1,000 mm LFP1000-N1NMB 1055623

G¾A
(acrylic glass)

With closed cover


1,100 mm
1,100 mm
LFP1100-G1NMB
LFP1100-G2NMB
1052076
1056293
H
I
¾” NPT With viewing panel made from PMMA 1,100 mm LFP1100-N1NMB 1059416
(acrylic glass) 1,200 mm LFP1200-G1NMB 1052077
G¾A
With closed cover 1,200 mm LFP1200-G21NMB 1056294
¾” NPT

G¾A
With viewing panel made from PMMA
(acrylic glass)
1,200 mm
1,300 mm
LFP1200-N1NMB
LFP1300-G1NMB
1059417
1052078
J
With closed cover 1,300 mm LFP1300-G2NMB 1056295
¾” NPT With viewing panel made from PMMA
(acrylic glass)
1,300 mm
1,400 mm
LFP1300-N1NMB
LFP1400-G1NMB
1059418
1052079
K
G¾A

¾” NPT
With closed cover

With viewing panel made from PMMA


1,400 mm
1,400 mm
LFP1400-G2NMB
LFP1400-N1NMB
1056296
1059419 L
(acrylic glass) 1,500 mm LFP1500-G1NMB 1052080

M
G¾A
With closed cover 1,500 mm LFP1500-G2NMB 1056297
¾” NPT With viewing panel made from PMMA 1,500 mm LFP1500-N1NMB 1059420
(acrylic glass)

N
1,600 mm LFP1600-G1NMB 1052081
G¾A
With closed cover 1,600 mm LFP1600-G2NMB 1056298
¾” NPT With viewing panel made from PMMA 1,600 mm LFP1600-N1NMB 1059421

G¾A
(acrylic glass)

With closed cover


1,700 mm
1,700 mm
LFP1700-G1NMB
LFP1700-G2NMB
1052082
1056299
O
¾” NPT 1,700 mm LFP1700-N1NMB 1059422

P
With viewing panel made from PMMA
(acrylic glass) 1,800 mm LFP1800-G1NMB 1052083
G¾A
With closed cover 1,800 mm LFP1800-G2NMB 1056300
¾” NPT

G¾A
With viewing panel made from PMMA
(acrylic glass)
1,800 mm
1,900 mm
LFP1800-N1NMB
LFP1900-G1NMB
1059423
1052084 Q
With closed cover 1,900 mm LFP1900-G2NMB 1056301

R
S
8017952/2016-05-02
Subject to change without notice
F l u i d s e n s o r s | SI C K 11
T
LFP Inox Level sensors

A Process connection
¾” NPT
Housing design Probe length
1,900 mm
Type
LFP1900-N1NMB
Part no.
1059424
With viewing panel made from PMMA

B
LFP2000-G1NMB 1052085
(acrylic glass) 2,000 mm
G¾A LFP2000-G1NMBL 1073552
With closed cover 2,000 mm LFP2000-G2NMB 1056302

C ¾” NPT 2,000 mm
2,100 mm
LFP2000-N1NMB
LFP2100-G1NMB
1059425
1065358

D
2,200 mm LFP2200-G1NMB 1063398
2,300 mm LFP2300-G1NMB 1065359
2,400 mm LFP2400-G1NMB 1065360

E 2,500 mm
2,600 mm
LFP2500-G1NMB
LFP2600-G1NMB
1065361
1065362
2,700 mm LFP2700-G1NMB 1065363

F 2,800 mm
2,900 mm
LFP2800-G1NMB
LFP2900-G1NMB
1064856
1065346
With viewing panel made from PMMA
3,000 mm LFP3000-G1NMB 1065347
G¾A (acrylic glass)
3,100 mm LFP3100-G1NMB 1065348
3,200 mm LFP3200-G1NMB 1065349

H 3,300 mm
3,400 mm
LFP3300-G1NMB
LFP3400-G1NMB
1065350
1065351

I
3,500 mm LFP3500-G1NMB 1065352
3,600 mm LFP3600-G1NMB 1065353
3,700 mm LFP3700-G1NMB 1065354

J 3,800 mm
3,900 mm
LFP3800-G1NMB
LFP3900-G1NMB
1065355
1065356
4,000 mm LFP4000-G1NMB 1065357

K • Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050

L
• Output signal: 1 x PNP + 3 x PNP/NPN + 4 mA ... 20 mA / 0 V ... 10 V
• Process temperature: –20 °C ... +150 °C
• Process pressure: –1 bar ... 16 bar
• Housing material: 303
M • Electrical connection: round connector M12 x 1, 8-pin
Process connection Housing design Probe length Type Part no.

N G¾A
With viewing panel made from
PMMA (acrylic glass)
With closed cover
500 mm

500 mm
LFP0500-G6NMC

LFP0500-G7NMC
1080617

1080618

O ¾” NPT

G¾A
With viewing panel made from
PMMA (acrylic glass)
500 mm
1,000 mm
LFP0500-N6NMC
LFP1000-G6NMC
1080639
1077065
With closed cover 1,000 mm LFP1000-G7NMC 1080623

P ¾” NPT With viewing panel made from


PMMA (acrylic glass)
1,000 mm
2,000 mm
LFP1000-N6NMC
LFP2000-G6NMC
1077066
1080628
G¾A

Q
With closed cover 2,000 mm LFP2000-G7NMC 1080629
With viewing panel made from
¾” NPT 2,000 mm LFP2000-N6NMC 1080634
PMMA (acrylic glass)

R
S
T 12 F l u i d s e n s o r s | SI C K 8017952/2016-05-02
Subject to change without notice
Level sensors LFP Inox




Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050
Output signal: 1 x PNP + 1 x PNP/NPN + 4 mA ... 20 mA / 0 V ... 10 V
Process temperature: –20 °C ... +150 °C
A
B
• Process pressure: –1 bar ... 16 bar
• Housing material: 303
• Electrical connection: Cable connector M12 x 1, 5-polig
Process connection Housing design
With viewing panel made from
PMMA (acrylic glass)
Probe length

500 mm
Type

LFP0500-GANMB
Part no.

1080619
C
G¾A

¾” NPT
With closed cover

With viewing panel made from


500 mm
500 mm
LFP0500-GBNMB
LFP0500-NANMB
1080620
1080640 D
PMMA (acrylic glass) 1,000 mm LFP1000-GANMB 1080624
G¾A

¾” NPT
With closed cover

With viewing panel made from


1,000 mm
1,000 mm
LFP1000-GBNMB
LFP1000-NANMB
1080625
1080637
E
F
PMMA (acrylic glass) 2,000 mm LFP2000-GANMB 1080630
G¾A
With closed cover 2,000 mm LFP2000-GBNMB 1080631
With viewing panel made from
¾” NPT 2,000 mm LFP2000-NANMB 1080635
PMMA (acrylic glass)

• Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050





Output signal: 1 x PNP + 3 x PNP/NPN + 4 mA ... 20 mA / 0 V ... 10 V
Process temperature: –20 °C ... +150 °C
Process pressure: –1 bar ... 16 bar
H
I
• Housing material: 303
• Electrical connection: Cable connector M12 x 1, 8-polig
Process connection Housing design Probe length Type Part no.

G¾A
With viewing panel made from
PMMA (acrylic glass)
With closed cover
500 mm

500 mm
LFP0500-GCNMC

LFP0500-GDNMC
1080621

1080622
J
¾” NPT

G¾A
With viewing panel made from
PMMA (acrylic glass)
With closed cover
500 mm

1,000 mm
LFP0500-NCNMC

LFP1000-GDNMC
1080641

1080627
K
¾” NPT

G¾A
With viewing panel made from
PMMA (acrylic glass)
With closed cover
1,000 mm

2,000 mm
LFP1000-NCNMC

LFP2000-GDNMC
1080638

1080633
L
M
With viewing panel made from
¾” NPT 2,000 mm LFP2000-NCNMC 1080636
PMMA (acrylic glass)

N
O
P
Q
R
S
8017952/2016-05-02
Subject to change without notice
F l u i d s e n s o r s | SI C K 13
T
LFP Inox Level sensors

A Remote amplifier
• Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050
• Output signal: 1 x PNP + 1 x PNP/NPN + 4 mA ... 20 mA / 0 V ... 10 V

B •

Process temperature: –20 °C ... +180 °C
Process pressure: –1 bar ... 16 bar
• Housing material: 303

C • Electrical connection: round connector M12 x 1, 5-pin


Process connection Housing design Probe length Cable length Type Part no.

D
G¾A 300 mm 3.3 m LFP0300-G1DMB 1071124
¾” NPT 300 mm 3.3 m LFP0300-N1DMB 1071139
1m LFP0500-G1BMB 1071118

E G¾A 500 mm 2m
3.3 m
LFP0500-G1CMB
LFP0500-G1DMB
1071121
1071125
1m LFP0500-N1BMB 1071133

F
With viewing panel
¾” NPT made from PMMA 500 mm 2m LFP0500-N1CMB 1071136
(acrylic glass)
3.3 m LFP0500-N1DMB 1071140
G¾A 700 mm 3.3 m LFP0700-G1DMB 1071126
¾” NPT 700 mm 3.3 m LFP0700-N1DMB 1071141
1m LFP1000-G1BMB 1071119

H 1,000 mm 2m
3.3 m
LFP1000-G1CMB
LFP1000-G1DMB
1071122
1071127
G¾A

I
1m LFP1000-G2BMB 1071128
With closed cover 1,000 mm 2m LFP1000-G2CMB 1071130
3.3 m LFP1000-G2DMB 1071132

J With viewing panel


made from PMMA 1,000 mm
1m
2m
LFP1000-N1BMB
LFP1000-N1CMB
1071134
1071137
(acrylic glass)
3.3 m LFP1000-N1DMB 1071142

K ¾” NPT

With closed cover 1,000 mm


1m
3.3 m
LFP1000-N2BMB
LFP1000-N2DMB
1071143
1071147

L With viewing panel


made from PMMA 2,000 mm
2m
1m
LFP1000-NCBMB
LFP2000-G1BMB
1071145
1071120
2m LFP2000-G1CMB 1071123

M
(acrylic glass)
G¾A
1m LFP2000-G2BMB 1071129
With closed cover 2,000 mm
2m LFP2000-G2CMB 1071131

N
With viewing panel 1m LFP2000-N1BMB 1071135
made from PMMA 2,000 mm
(acrylic glass) 2m LFP2000-N1CMB 1071138
¾” NPT
1m LFP2000-N2BMB 1071144

O G¾A
With closed cover 2,000 mm

3,000 mm
2m
2m
LFP2000-N2CMB
LFP3000-G1CMB
1071146
1072031

P ¾” NPT With viewing panel 3,000 mm 2m LFP3000-N1CMB 1072032


made from PMMA
G¾A (acrylic glass) 4,000 mm 1m LFP4000-G1BMB 1072030
¾” NPT 4,000 mm 1m LFP4000-N1BMB 1072033

Q
R
S
T 14 F l u i d s e n s o r s | SI C K 8017952/2016-05-02
Subject to change without notice
Level sensors LFP Inox

Type code
A
Probe length in mm

B
0200 200 mm (steps of 10 mm)
4000 4,000 mm
Process connection/probe design
G G ¾ A (connection for hygienic adapters) / probe in 316L

C
N ¾” NPT / probe in 316L
Housing/display/electrical connection
1 Stainless steel housing with PMMA viewing window, display / M12 x 1, 5-pin
2 Stainless steel housing without viewing window, display / M12 x 1, 5-pin
3 Stainless steel housing without viewing window, according to 3-A guidelines, display / M12 x 1, 5-pin
6 Stainless steel housing with PMMA viewing window, display / M12 x 1, 8-pin
7 Stainless steel housing without viewing window / M12 x 1, 8-pin
A Stainless steel housing with PMMA viewing window, display / cable connector, 5-pin
D
B Stainless steel housing without viewing window / cable connector, 5-pin

E
C Stainless steel housing with PMMA viewing window, display / cable connector, 8-pin
D Stainless steel housing without viewing window / cable connector, 8-pin
Application type
N Standard

F
B Remote amplifier / cable length 1 m
C Remote amplifier / cable length 2 m
D Remote amplifier / cable length 3.3 m
Signal output
M 4 mA … 20 mA / 0 V … 10 V, configurable
Switching output
B 1 x PNP + 1 x PNP/NPN
C 1 x PNP + 3 x PNP/NPN
Device type

H
Standard
L PWIS-cleaned

LFP - M

Not all variations of the type code can be combined!


I
Max. probe length (mm)
Coaxial cable length (mm) Foam mode inactive Foam mode active
J
K
1,000 4,000 2,000

2,000 3,000 1,500

3,300 1,000 500

L
M
N
O
P
Q
R
S
8017952/2016-05-02
Subject to change without notice
F l u i d s e n s o r s | SI C K 15
T
LFP Inox Level sensors

A Dimensional drawings (Dimensions in mm (inch))

Standard

B
54

C
( 2.13)
(4.84)
123

(5.71)
D

145
(3.03)
77
32

(1.50)
36

(0.87)

38
(1.26)

E
(1.42)

22
G 3/4 A

(0.59)
(0.87)

3/4" NPT

15
22

M12x1

F
IA

IA
G 3/4 A
3/4" NPT
L

L
M

H
M
7
( 0.28)

I 20
M: Measuring range
L: Probe length
IAE IA: Inactive area at process connection
IAE

J
(0.78) 25 mm (0.79")
IAE: Inactive area at probe end
Monoprobe with coaxial tube 10 mm (0.39")

K Cable connector
54
( 2.13)

L
M
(4.84)
123

(1.69)
43

M12
(3.03)

N
77

36
(1.42)

O
(0.87)

G 3/4 A
22

3/4" NPT
(ca. 393.7)
ca. 10000
IA

P
L

7
M

(4.53)
115

( 0.28)

Q
IAE

M: Measuring range

R L: Probe length
IA: Inactive area at process connection
25 mm (0.79")
IAE: Inactive area at probe end 10 mm (0.39")

S
T 16 F l u i d s e n s o r s | SI C K 8017952/2016-05-02
Subject to change without notice
Level sensors LFP Inox

Remote amplifier

C: Cable length
A
M: Measuring range
L:
IA:
Probe length
Inactive area at process connection
20 mm (0.79") / 40 mm (1.58")
B
(3.72)
94.4

IAE: Inactive area at probe end 10 mm (0.39")

C
(5.21)
132.4 36
(1.42) D
E
0.26)
6.5

(0.55)
14
(

.97)
F
6

(mi . R50
C
40

n.R1
(0.24)
(1.58)

min
70

(5.59)
142
(2.76)

54

H
( 2.13)

(0.87)
22
36
40 (1.42)
( 1.58)
I
(2.87)

G 3/4 A
73

3/4" NPT

J
IA
M12x1

L
M
38 ( 0.28)
(1.50)
K
L
IAE
All dimensions in mm (inch)

M
N
O
P
Q
R
S
8017952/2016-05-02
Subject to change without notice
F l u i d s e n s o r s | SI C K 17
T
LFP Inox Level sensors

A Connection type
M12 round connector, 5-pin M12 round connector, 8-pin

B
C 



   
D 
 
 

E
F 1 L+: Supply voltage, brown
2 QA: Analog current-/voltage output, white
1 L+: Supply voltage
2 Q2: Switching output 2, PNP/NPN
3 M: Ground, reference ground for current-/voltage output, blue 3 M: Ground, reference ground for current-/voltage output
4 C/Q1: Switching output 1, PNP/IO-Link-communication, black 4 C/Q1: Switching output 1, PNP/IO-Link-communication
5 Q2: Switching output 2, PNP/NPN, grey 5 Q3: Switching output 3, PNP/NPN
6 Q4: Switching output 4, PNP/NPN
7 QA: Analog current-/voltage output

H Cable connector, 5-pin Cable connector, 8-pin


8 No function

I
J L+: Supply voltage, brown
QA: Analog current-/voltage output,
L+: Supply voltage, white
Q2: Switching output 2, PNP/NPN,
white brown

K M: Ground, reference ground for cur-


rent-/voltage output, blue
C/Q1: Switching output 1, PNP/IO-
M: Ground, reference ground for cur-
rent-/voltage output, green
C/Q1: Switching output 1, PNP/IO-
Link-communication, black Link-communication, yellow

L Q2: Switching output 2, PNP/NPN,


grey
Q3: Switching output 3, PNP/NPN,
gray
Q4: Switching output 4, PNP/NPN,
rose

M QA: Analog current-/voltage output,


blue
No function, red

N
O
P
Q
R
S
T 18 F l u i d s e n s o r s | SI C K 8017952/2016-05-02
Subject to change without notice
Level sensors LFP Inox

Accessories
Mounting systems
A
Mounting brackets and mounting plates
Mounting brackets
B
Brief description Type Part no.
C
Mounting bracket, mounting hardware included BEF-FL-304LFP-HLDR 2077391

Flanges
D
Flange plates

Brief description Type Part no.


E
Hygienic process connection adapter, collar connector (DIN 11864-1) DN 25
Form A with grooved union nut
BEF-HA-641D25-LFP1 2058795 F
Hygienic process connection adapter, collar connector (DIN 11864-2) DN 25
BEF-HA-642D25-LFP1 2058823
Form A

Hygienic process connection adapter, collar clamp connector (DIN 11864-3) BKS
DN 25 Form A
BEF-HA-643D25-LFP1 2058821
H
Hygienic process connection adapter, conical connector (DIN 11851) DN 25 with
grooved union nut
BEF-HA-851D25-LFP1 2058138
I
J
Hygienic process connection adapter, conical connector (DIN 11851) DN 40 with
BEF-HA-851D40-LFP1 2058139
grooved union nut, material 1.4404 (Ra ≤ 0.8 µm)

Hygienic process connection adapter, conical connector (DIN 11851) DN 50 with


BEF-HA-851D50-LFP1 2058141

K
grooved union nut
Hygienic process connection adapter, conical connector (DIN 11851) DN 65 with
BEF-HA-851D65-LFP1 2063328
grooved union nut

L
Hygienic process connection adapter, Tri-Clamp 1’’ and 1 ½’’ BEF-HA-TCLI10-LFP1 2058808
Hygienic process connection adapter, Tri-Clamp 1’’ and 1 ½’’ with leakage indi-
BEF-HA-TCLI10-LFP3 2058851
cation port according to 3-A guidelines
Hygienic process connection adapter, Tri-Clamp 2” BEF-HA-TCLI20-LFP1 2058824
Hygienic process connection adapter, Tri-Clamp 2 ½”
Hygienic process connection adapter, Tri-Clamp 3”
BEF-HA-TCLI25-LFP1
BEF-HA-TCLI30-LFP1
2069518
2064771
M
Hygienic process connection adapter, Varivent Connector Type N BEF-HA-VARTYN-LFP1 2058822 N
Weld-in flange

Brief description Type Part no.


O
P
Welded flange/welded connector, process connection Tri-Clamp 1”, Stainless
BEF-FL-TCLI10-LFV2 5321678
steel 1.4404
Welded flange/welded connector, process connection Tri-Clamp 2”, Stainless
BEF-FL-TCLI20-LFV2 5321679
steel 1.4404

Welded flange hygienic G ¾”, Stainless steel 1.4404 BEF-HA-SWFL54-LFP1 2061268 Q


R
S
8017952/2016-05-02
Subject to change without notice
F l u i d s e n s o r s | SI C K 19
T
LFP Inox Level sensors

A BEF-HA-641D25-LFP1

34

B
(1.11)
28.2

(1.34)

C
42.9
( 1.69)

BEF-HA-643D25-LFP1

D 34
(0.94)
23.9

(1.34)

E 38.4
( 1.51)

F (
50.5
1.99)

BEF-HA-851D25-LFP1

34
0.90)
22.9

(1.34)

H
(

27

I
( 1.06

BEF-HA-851D40-LFP1 BEF-HA-851D50-LFP1

J
36 36
(1.42) (1.42)
(0.98)

(0.98)
24.9

24.9

K (
38
1.50) (
51
2.01)

L BEF-HA-851D65-LFP1

M
36
(1.42)
(0.98)
24.9

N 67
( 2.64)

O BEF-HA-TCLI10-LFP1 BEF-HA-TCLI10-LFP3

P 34
(0.90)

34
22.9
(0.9)

22.9

(1.34) (1.34)

Q (
43.5
1.71)
50.5
(
43.5
1.71)

50.5

R
( 1.99) ( 1.99)

S
T 20 F l u i d s e n s o r s | SI C K 8017952/2016-05-02
Subject to change without notice
Level sensors LFP Inox

BEF-HA-TCLI20-LFP1 BEF-HA-TCLI25-LFP1
A
36 41
(0.90)

(0.90)
B
22.9

22.9
(1.42) (1.61)

70.5

C
56.5
( 2.22) ( 2.78)

64 77.5
( 2.52) ( 3.05)

BEF-HA-TCLI30-LFP1 BEF-HA-VARTYN-LFP1
D
41 36
(1.42) E
(0.90)
22.9

(1.61)

(1.06)
27
(
83.5
3.29)
64
F
( 2.52)
91 84
( 3.58) ( 3.31)

BEF-HA-SWFL54-LFP1 H
I
(0.90)
22.9

(
43.6
1.71)
J
K
54
( 2.13)

L
M
N
O
P
Q
R
S
8017952/2016-05-02
Subject to change without notice
F l u i d s e n s o r s | SI C K 21
T
LFP Inox Level sensors

A Device protection (mechanical)


Protective housings and protective pipes

B Brief description
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
Type

LFPCT-0200G1
Part no.

2068141
probe G ¾, material 1.4571/316TI, for probe length 200 mm

C Coaxial probe for LFP with process connection G ¾, process connection of coaxial
probe ¾” NPT, material 1.4571/316TI, for probe length 200 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0200N1 2068165

LFPCT-0300G1 2068142

D
probe G ¾, material 1.4571/316TI, for probe length 300 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0300N1 2068166
probe ¾” NPT, material 1.4571/316TI, for probe length 300 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial

E
LFPCT-0400G1 2068143
probe G ¾, material 1.4571/316TI, for probe length 400 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0400N1 2068167
probe ¾” NPT, material 1.4571/316TI, for probe length 400 mm

F
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0500G1 2068144
probe G ¾, material 1.4571/316TI, for probe length 500 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0500N1 2068168
probe ¾” NPT, material 1.4571/316TI, for probe length 500 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0600G1 2068145
probe G ¾, material 1.4571/316TI, for probe length 600 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0600N1 2068169

H
probe ¾” NPT, material 1.4571/316TI, for probe length 600 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0700G1 2068146
probe G ¾, material 1.4571/316TI, for probe length 700 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial

I
LFPCT-0700N1 2068170
probe ¾” NPT, material 1.4571/316TI, for probe length 700 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0800G1 2068147
probe G ¾, material 1.4571/316TI, for probe length 800 mm

J
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
Illustration may probe ¾” NPT, material 1.4571/316TI, for probe length 800 mm
LFPCT-0800N1 2068171
differ
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0900G1 2067507
probe G ¾, material 1.4571/316TI, for probe length 900 mm

K Coaxial probe for LFP with process connection G ¾, process connection of coaxial
probe G ¾, material 1.4571/316TI, for probe length 1,000 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-1000G1 2065702

LFPCT-1100G1 2068148

L
probe G ¾, material 1.4571/316TI, for probe length 1,100 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-1200G1 2068149
probe G ¾, material 1.4571/316TI, for probe length 1,200 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial

M
LFPCT-1300G1 2068150
probe G ¾, material 1.4571/316TI, for probe length 1,300 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-1400G1 2068151
probe G ¾, material 1.4571/316TI, for probe length 1,400 mm

N
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-1500G1 2068152
probe G ¾, material 1.4571/316TI, for probe length 1,500 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-1600G1 2068153
probe G ¾, material 1.4571/316TI, for probe length 1,600 mm

O Coaxial probe for LFP with process connection G ¾, process connection of coaxial
probe G ¾, material 1.4571/316TI, for probe length 1,700 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-1700G1 2068154

LFPCT-1800G1 2068155

P
probe G ¾, material 1.4571/316TI, for probe length 1500 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-1900G1 2068156
probe G ¾, material 1.4571/316TI, for probe length 1,900 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial

Q
LFPCT-2000G1 2065703
probe G ¾, material 1.4571/316TI, for probe length 2,000 mm

R
S
T 22 F l u i d s e n s o r s | SI C K 8017952/2016-05-02
Subject to change without notice
Level sensors LFP Inox

Terminal and alignment brackets


Alignment brackets
A
Brief description

1 piece, Centering for bypass- and immersion tube installation with diameter
Type Part no.
B
BEF-FL-BYRD40-LFP1 2059612

C
40 mm ... 100 mm, PTFE

Connection systems
Modules and gateways
Fieldbus modules
D
Brief description
Number of IO-Link ports: 4; Communication mode: COM1/COM2; IO-Link version:
Type Part no.
E
IO-Link V1.0; Switching input: PNP; Supply voltage Vs, IO-Link ports: DC 24 V; Current
loading: 800 mA; Data transmission rate: Max. 12 MBaud, Autobaud; Address space
occupation: 1 bis 126; Connection type: Connector M12; Connection type, IO-Link
ports: Connector M12, 5-pin; Suppyl voltage Vs, module: DC 18 V ... 30 V; Power con-
IOLSHPB-P3104R01 6039728 F
sumption: Typ. 75 mA / max. 100 mA (at UL with DC 24 V), Typ. 25 mA + sensor current
/ max. 80

H
Plug connectors and cables
Connecting cables with female connector

I
Brief description Type Part no.
Head A: female connector, M12, 5-pin, straight
Head B: cable
Cable: PVC, unshielded, 2 m DOL-1205-G02MNI 6052625
This product is generally resistant to chemical cleaning agents (see ECOLAB). Please
do not use cleaning agents of any other Kind.
Head A: female connector, M12, 5-pin, straight
J
K
Head B: cable
Cable: PVC, unshielded, 5 m DOL-1205-G05MNI 6052626
This product is generally resistant to chemical cleaning agents (see ECOLAB). Please
do not use cleaning agents of any other Kind.
Head A: female connector, M12, 5-pin, straight
Head B: cable
Cable: PVC, unshielded, 10 m DOL-1205-G10MNI 6052627
L
This product is generally resistant to chemical cleaning agents (see ECOLAB). Please
do not use cleaning agents of any other Kind.
M
Further accessories
Hardware N
O
Brief description Type Part no.
APR-WP-
Weather protection cover for LFP Inox, material: 304 2069530
LFP001-0001

Spare parts
P
Brief description Type Part no.
Spare coaxial cable for LFP Inox, remote amplifier, length 1 m
Spare coaxial cable for LFP Inox, remote amplifier, length 2 m
CBL-CX-001000-LFPI
CBL-CX-002000-LFPI
2077795
2077796
Q
Illustration may

R
differ
Spare coaxial cable for LFP Inox, remote amplifier, length 3.3 m CBL-CX-003300-LFPI 2077797
Cover with viewing
Cover closed for LFP Inox, material 1.4305 2067269
window

S
Cover without view-
Cover for LFP Inox with inspection window, material 1.4305 and PMMA 2067267
ing window

8017952/2016-05-02
Subject to change without notice
F l u i d s e n s o r s | SI C K 23
T
LFP Cubic Level sensors

A
B FLEXIBLE UP TO THE PROBE TIP
C Product description

D The LFP Cubic is a level sensor for liq-


uids using TDR technology – a process
for determining the time of flight of
any liquid. Thanks to its modular probe,
the sensor can be integrated quickly into
any application. It can even be used in

E electromagnetic waves. The time differ-


ence between the sent pulse and the
reflected pulse is used to generate a
deposit-forming and foaming liquids. The
sensor’s intuitive setup uses four push-
buttons and a display to ensure quick

F
level signal. The sensor can emit this a and easy adaptation to the application.
as continuous measured value (analog Remote amplifier, IO-Link interface,
output) and a freely positionable switch- and a design which features a process
ing point (switching output). The LFP connection in titanium are additional
Cubic is compatible for use in virtually features for versatile use.

H
At a glance
• Level sensor for liquids • Process temperature up to 100 °C;
• No mechanical moving parts process pressure up to 10 bar

I • Interchangeable and retractable


probe from 200 mm to 2,000 mm
and cable probe up to 4,000 mm
• 3-in-1: combined display, analog
output (according to NAMUR NE 43),
and binary output

J • Resistant to deposit formation • High enclosure rating of IP67, rotat-


able housing and remote amplifier

K Your benefits
• Rugged design increases service life • Titanium process connection brings
• High flexibility due to cutable and ex- high chemical resistance

L changable monoprobe or rope probe


• Cost savings due to multiple output
• Compact and rotatable housing or
remote amplifier ensures flexible
signals: one system for both level installation

M detection and continuous level moni-


toring
• No crosstalk when several sensors
are mounted next to each other
• Time and cost savings due to low • Advanced technology enables

N maintenance and quick commission-


ing without calibration
adjustment-free measurement

O
P Additional information

Q Detailed technical data����������������������25


Ordering information������������������������� 26

R
Type code������������������������������������������� 34
Dimensional drawings����������������������� 35
Connection type��������������������������������� 38 -- www.sick.com/LFP_Cubic

S Accessories��������������������������������������� 38 For more information, simply enter the link or scan the QR code and get direct access to techni-
cal data, CAD design models, operating instructions, software, application examples, and much
more.

T 24 F l u i d s e n s o r s | SI C K 8017952/2016-05-02
Subject to change without notice
Level sensors LFP Cubic

Detailed technical data


Features
A
Medium
Measurement
Fluids
Switch, Continuous
B
C
Design Standard
Remote amplifier, length of cable 1 m
Remote amplifier, length of cable 2 m
Remote amplifier, length of cable 3.3 m (depending on type)
Probe type Without probe
Rod probe
D
Rope probe (depending on type)
Probe length 200 mm ... 2,000 mm (rod probe)
1,000 mm, 2,000 mm, 3,000 mm, 4,000 mm (rope probe) E
Process pressure –1 bar ... +10 bar
Process temperature
GOST approval
–20 °C ... +100 °C
l
F
RoHS certificate l
IO-Link l
CULus certificate l
PWIS-cleaned – / l (depending on type)
H
Performance
Accuracy of sensor element
Repeatability
± 5 mm 1)
≤ 2 mm
I
Resolution
Response time
< 2 mm
< 400 ms J
Dielectricity constant ≥ 5 for mono rod probe / rope probe

Conductivity
≥ 1.8 with coaxial probe
No limitation K
Maximum level change ≤ 500 mm/s
Deactivated area at end of probe
MTTF
10 mm 2)
194.3 years (EN ISO 13849-1)
L
M
1)
For details see accuracy diagram in the operating instructions LFP Cubic.
2)
With water under reference conditions.

Mechanics
Wetted parts 1.4404, PTFE N
Process connection G¾A
¾” NPT
G ¾ A, Titanium
¾” NPT, Titanium (depending on type)
O
P
Housing material Plastic PBT
Max.probe load ≤ 6 Nm
Material coaxial cable PVC
Length coaxial cable 1 m ... 3.3 m (depending on type)
Q
Electronics
Supply voltage
Power consumption
12 V DC ... 30 V DC 1)
≤ 100 mA at 24 V DC without output load
R
All connections are polarity protected. All outputs are overload and short-circuit protected.
S
1)

8017952/2016-05-02
Subject to change without notice
F l u i d s e n s o r s | SI C K 25
T
LFP Cubic Level sensors

A Initialization time
Protection class
≤5s
III

B
Electrical connection Round connector M12 x 1, 5-pin
Round connector M12 x 1, 8-pin (depending on type)
Output signal 4 mA ... 20 mA, 0 V ... 10 V automatic switching depending on the load,

C
1 PNP transistor output (Q1) and 1 PNP/NPN transistor output (Q2) switchable, or
1 PNP transistor output (Q1) and 3 PNP/NPN transistor outputs (Q2 ... Q4) switchable
(depending on type) 1)
Output load 4 mA ... 20 mA < 500 Ohm at Uv > 15 V

D 4 mA ... 20 mA < 350 Ohm at Uv > 12 V


0 V ... 10 V > 750 Ohm at Uv 14 ≥ V
Hysteresis Min. 2 mm, free adjustable

E Signal voltage HIGH


Signal voltage LOW
Vs - 2 V
≤2V

F
Output current < 100 mA
Inductive load <1H
Capacitive load 100 nF
Enclosure rating IP 67: EN 60529
Temperature drift < 0.1 mm/K
Lower signal level 3.8 mA ... 4 mA

H Upper signal level


1)
20 mA ... 20.5 mA
All connections are polarity protected. All outputs are overload and short-circuit protected.

I Ambient data
Ambient operating temperature –20 °C ... +60 °C

J Ambient storage temperature


Ambient temperature coaxial cable
–40 °C ... +80 °C
–20 °C ... +60 °C

K
Outdoor use Unsuitable

Ordering information
L Without probe
• Enclosure rating: IP 67: EN 60529

M •


Process temperature: –20 °C ... +100 °C
Process pressure: –1 bar ... 10 bar
Housing material: Plastic PBT

N Process connection
G¾A
Output signal

1 x PNP + 1 x PNP/NPN + 4 mA ...


Electrical connection
Round connector M12 x 1, 5-pin
Type
LFP0025-A4NMB
Part no.
1060171
LFP0025-

O G ¾ A, Titanium 20 mA / 0 V ... 10 V Round connector M12 x 1, 5-pin 1062791


A4NMBS01
G¾A Round connector M12 x 1, 8-pin LFP0025-A5NMC 1064676
1 x PNP + 3 x PNP/NPN + 4 mA ...
LFP0025-

P
G ¾ A, Titanium 20 mA / 0 V ... 10 V Round connector M12 x 1, 8-pin 1070517
A5NMCS05
¾” NPT Round connector M12 x 1, 5-pin LFP0025-B4NMB 1060172
1 x PNP + 1 x PNP/NPN + 4 mA ...
20 mA / 0 V ... 10 V LFP0025-

Q
¾” NPT, Titanium Round connector M12 x 1, 5-pin 1075980
B4NMBS10
1 x PNP + 3 x PNP/NPN + 4 mA ...
¾” NPT Round connector M12 x 1, 8-pin LFP0025-B5NMC 1068941
20 mA / 0 V ... 10 V

R
S
T 26 F l u i d s e n s o r s | SI C K 8017952/2016-05-02
Subject to change without notice
Level sensors LFP Cubic

Rod probe with standard amplifier


• Enclosure rating: IP 67: EN 60529
A
• Process temperature: –20 °C ... +100 °C


Process pressure: –1 bar ... 10 bar
Housing material: Plastic PBT B
C
Process connection Output signal Electrical connection Probe length Type Part no.
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 200 mm LFP0200-A4NMB 1057073
1, 5-pin
10 V

D
G¾A
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 200 mm LFP0200-A5NMC 1062245
1, 8-pin
10 V

E
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 200 mm LFP0200-B4NMB 1057092
1, 5-pin
10 V
¾” NPT
1 x PNP + 3 x PNP/NPN

F
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 200 mm LFP0200-B5NMC 1062264
1, 8-pin
10 V
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 300 mm LFP0300-A4NMB 1057074
1, 5-pin
10 V
G¾A
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 300 mm LFP0300-A5NMC 1062246
1, 8-pin
10 V
1 x PNP + 1 x PNP/NPN
+ 4 mA ... 20 mA / 0 V ...
Round connector M12 x
300 mm LFP0300-B4NMB 1057093
H
1, 5-pin
10 V

I
¾” NPT
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 300 mm LFP0300-B5NMC 1062265
1, 8-pin
10 V

J
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 400 mm LFP0400-A4NMB 1057075
1, 5-pin
10 V
G¾A
1 x PNP + 3 x PNP/NPN

K
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 400 mm LFP0400-A5NMC 1062247
1, 8-pin
10 V
1 x PNP + 1 x PNP/NPN
Round connector M12 x

L
+ 4 mA ... 20 mA / 0 V ... 400 mm LFP0400-B4NMB 1057094
1, 5-pin
10 V
¾” NPT
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 400 mm LFP0400-B5NMC 1062266
1, 8-pin
10 V
1 x PNP + 1 x PNP/NPN
+ 4 mA ... 20 mA / 0 V ...
Round connector M12 x
500 mm LFP0500-A4NMB 1057076
M
1, 5-pin
10 V
G¾A
1 x PNP + 3 x PNP/NPN
+ 4 mA ... 20 mA / 0 V ...
10 V
Round connector M12 x
1, 8-pin
500 mm LFP0500-A5NMC 1062248 N
O
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 500 mm LFP0500-B4NMB 1057095
1, 5-pin
10 V
¾” NPT
1 x PNP + 3 x PNP/NPN

P
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 500 mm LFP0500-B5NMC 1062267
1, 8-pin
10 V
1 x PNP + 1 x PNP/NPN
Round connector M12 x

Q
+ 4 mA ... 20 mA / 0 V ... 600 mm LFP0600-A4NMB 1057077
1, 5-pin
10 V
G¾A
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 600 mm LFP0600-A5NMC 1062249

R
1, 8-pin
10 V

S
8017952/2016-05-02
Subject to change without notice
F l u i d s e n s o r s | SI C K 27
T
LFP Cubic Level sensors

A Process connection Output signal


1 x PNP + 1 x PNP/NPN
Electrical connection

Round connector M12 x


Probe length Type Part no.

+ 4 mA ... 20 mA / 0 V ... 600 mm LFP0600-B4NMB 1057096

B
1, 5-pin
10 V
¾” NPT
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 600 mm LFP0600-B5NMC 1062268
1, 8-pin

C
10 V
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 700 mm LFP0700-A4NMB 1057078
1, 5-pin
10 V

D
G¾A
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 700 mm LFP0700-A5NMC 1062250
1, 8-pin
10 V

E
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 700 mm LFP0700-B4NMB 1057097
1, 5-pin
10 V
¾” NPT
1 x PNP + 3 x PNP/NPN
Round connector M12 x

F
+ 4 mA ... 20 mA / 0 V ... 700 mm LFP0700-B5NMC 1062269
1, 8-pin
10 V
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 800 mm LFP0800-A4NMB 1057079
1, 5-pin
10 V
G¾A
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 800 mm LFP0800-A5NMC 1062251
1, 8-pin

H
10 V
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 800 mm LFP0800-B4NMB 1057098
1, 5-pin
10 V

I
¾” NPT
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 800 mm LFP0800-B5NMC 1062270
1, 8-pin
10 V

J
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 900 mm LFP0900-A4NMB 1057080
1, 5-pin
10 V
G¾A
1 x PNP + 3 x PNP/NPN
Round connector M12 x

K + 4 mA ... 20 mA / 0 V ...
10 V
1 x PNP + 1 x PNP/NPN
1, 8-pin
900 mm LFP0900-A5NMC 1062252

Round connector M12 x


+ 4 mA ... 20 mA / 0 V ... 900 mm LFP0900-B4NMB 1057099

L
1, 5-pin
10 V
¾” NPT
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 900 mm LFP0900-B5NMC 1062271
1, 8-pin

M
10 V
1 x PNP + 1 x PNP/NPN LFP1000-A4NMB 1057081
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,000 mm
1, 5-pin LFP1000-A4NMBL 1073549
10 V

N
G¾A
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,000 mm LFP1000-A5NMC 1062253
1, 8-pin
10 V

O
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,000 mm LFP1000-B4NMB 1057100
1, 5-pin
10 V
¾” NPT
1 x PNP + 3 x PNP/NPN
Round connector M12 x

P + 4 mA ... 20 mA / 0 V ...
10 V
1 x PNP + 1 x PNP/NPN
1, 8-pin
1,000 mm LFP1000-B5NMC 1062272

Round connector M12 x


+ 4 mA ... 20 mA / 0 V ... 1,100 mm LFP1100-A4NMB 1057082

Q
1, 5-pin
10 V
G¾A
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,100 mm LFP1100-A5NMC 1062254
1, 8-pin

R
10 V

S
T 28 F l u i d s e n s o r s | SI C K 8017952/2016-05-02
Subject to change without notice
Level sensors LFP Cubic

Process connection Output signal


1 x PNP + 1 x PNP/NPN
Electrical connection

Round connector M12 x


Probe length Type Part no.
A
+ 4 mA ... 20 mA / 0 V ... 1,100 mm LFP1100-B4NMB 1057101

B
1, 5-pin
10 V
¾” NPT
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,100 mm LFP1100-B5NMC 1062273
1, 8-pin

C
10 V
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,200 mm LFP1200-A4NMB 1057083
1, 5-pin
10 V

D
G¾A
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,200 mm LFP1200-A5NMC 1062255
1, 8-pin
10 V

E
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,200 mm LFP1200-B4NMB 1057102
1, 5-pin
10 V
¾” NPT
1 x PNP + 3 x PNP/NPN
Round connector M12 x

F
+ 4 mA ... 20 mA / 0 V ... 1,200 mm LFP1200-B5NMC 1062274
1, 8-pin
10 V
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,300 mm LFP1300-A4NMB 1057084
1, 5-pin
10 V
G¾A
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,300 mm LFP1300-A5NMC 1062256
1, 8-pin

H
10 V
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,300 mm LFP1300-B4NMB 1057103
1, 5-pin
10 V

I
¾” NPT
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,300 mm LFP1300-B5NMC 1062275
1, 8-pin
10 V

J
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,400 mm LFP1400-A4NMB 1057085
1, 5-pin
10 V
G¾A
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ...
10 V
1 x PNP + 1 x PNP/NPN
1, 8-pin
1,400 mm LFP1400-A5NMC 1062257
K
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,400 mm LFP1400-B4NMB 1057104

L
1, 5-pin
10 V
¾” NPT
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,400 mm LFP1400-B5NMC 1062276
1, 8-pin

M
10 V
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,500 mm LFP1500-A4NMB 1057086
1, 5-pin
10 V

N
G¾A
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,500 mm LFP1500-A5NMC 1062258
1, 8-pin
10 V

O
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,500 mm LFP1500-B4NMB 1057105
1, 5-pin
10 V
¾” NPT
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ...
10 V
1 x PNP + 1 x PNP/NPN
1, 8-pin
1,500 mm LFP1500-B5NMC 1062277
P
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,600 mm LFP1600-A4NMB 1057087

Q
1, 5-pin
10 V
G¾A
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,600 mm LFP1600-A5NMC 1062259
1, 8-pin

R
10 V

S
8017952/2016-05-02
Subject to change without notice
F l u i d s e n s o r s | SI C K 29
T
LFP Cubic Level sensors

A Process connection Output signal


1 x PNP + 1 x PNP/NPN
Electrical connection

Round connector M12 x


Probe length Type Part no.

+ 4 mA ... 20 mA / 0 V ... 1,600 mm LFP1600-B4NMB 1057106

B
1, 5-pin
10 V
¾” NPT
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,600 mm LFP1600-B5NMC 1062278
1, 8-pin

C
10 V
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,700 mm LFP1700-A4NMB 1057088
1, 5-pin
10 V

D
G¾A
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,700 mm LFP1700-A5NMC 1062260
1, 8-pin
10 V

E
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,700 mm LFP1700-B4NMB 1057107
1, 5-pin
10 V
¾” NPT
1 x PNP + 3 x PNP/NPN
Round connector M12 x

F
+ 4 mA ... 20 mA / 0 V ... 1,700 mm LFP1700-B5NMC 1062279
1, 8-pin
10 V
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,800 mm LFP1800-A4NMB 1057089
1, 5-pin
10 V
G¾A
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,800 mm LFP1800-A5NMC 1062261
1, 8-pin

H
10 V
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,800 mm LFP1800-B4NMB 1057108
1, 5-pin
10 V

I
¾” NPT
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,800 mm LFP1800-B5NMC 1062280
1, 8-pin
10 V

J
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,900 mm LFP1900-A4NMB 1057090
1, 5-pin
10 V
G¾A
1 x PNP + 3 x PNP/NPN
Round connector M12 x

K + 4 mA ... 20 mA / 0 V ...
10 V
1 x PNP + 1 x PNP/NPN
1, 8-pin
1,900 mm LFP1900-A5NMC 1062262

Round connector M12 x


+ 4 mA ... 20 mA / 0 V ... 1,900 mm LFP1900-B4NMB 1057109

L
1, 5-pin
10 V
¾” NPT
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 1,900 mm LFP1900-B5NMC 1062281
1, 8-pin

M
10 V
1 x PNP + 1 x PNP/NPN LFP2000-A4NMB 1057091
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 2,000 mm
1, 5-pin LFP2000-A4NMBL 1073550
10 V

N
G¾A
1 x PNP + 3 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 2,000 mm LFP2000-A5NMC 1062263
1, 8-pin
10 V

O
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 2,000 mm LFP2000-B4NMB 1057110
1, 5-pin
10 V
¾” NPT
1 x PNP + 3 x PNP/NPN
Round connector M12 x

P + 4 mA ... 20 mA / 0 V ...
10 V
1, 8-pin
2,000 mm LFP2000-B5NMC 1062282

Q
R
S
T 30 F l u i d s e n s o r s | SI C K 8017952/2016-05-02
Subject to change without notice
Level sensors LFP Cubic

Rod probe with remote amplifier


• Enclosure rating: IP 67: EN 60529
A
• Process temperature: –20 °C ... +100 °C


Process pressure: –1 bar ... 10 bar
Housing material: Plastic PBT B
C
Process connec- Output signal Electrical connec- Probe length Cable length Type Part no.
tion tion
1 x PNP + 1 x PNP/
NPN + 4 mA ... Round connector

D
300 mm 3.3 m LFP0300-A4DMB 1071084
20 mA / 0 V ... M12 x 1, 5-pin
10 V
G¾A
1 x PNP + 3 x PNP/
NPN + 4 mA ... Round connector
20 mA / 0 V ...
10 V
M12 x 1, 8-pin
300 mm 3.3 m LFP0300-A5DMC 1071094
E
1 x PNP + 1 x PNP/

F
NPN + 4 mA ... Round connector
300 mm 3.3 m LFP0300-B4DMB 1071104
20 mA / 0 V ... M12 x 1, 5-pin
10 V
¾” NPT
1 x PNP + 3 x PNP/
NPN + 4 mA ... Round connector
300 mm 3.3 m LFP0300-B5DMC 1071114
20 mA / 0 V ... M12 x 1, 8-pin
10 V

H
1 x PNP + 1 x PNP/ 1m LFP0500-A4BMB 1071078
NPN + 4 mA ... Round connector
500 mm 2m LFP0500-A4CMB 1071081
20 mA / 0 V ... M12 x 1, 5-pin
10 V 3.3 m LFP0500-A4DMB 1071085

I
G¾A
1 x PNP + 3 x PNP/ 1m LFP0500-A5BMC 1071088
NPN + 4 mA ... Round connector
500 mm 2m LFP0500-A5CMC 1071091
20 mA / 0 V ... M12 x 1, 8-pin
10 V 3.3 m LFP0500-A5DMC 1071095
1 x PNP + 1 x PNP/
NPN + 4 mA ... Round connector
500 mm
1m
2m
LFP0500-B4BMB
LFP0500-B4CMB
1071098
1071101
J
20 mA / 0 V ... M12 x 1, 5-pin

¾” NPT
10 V
1 x PNP + 3 x PNP/
NPN + 4 mA ... Round connector
3.3 m
1m
LFP0500-B4DMB
LFP0500-B5BMC
1071105
1071108 K
500 mm 2m LFP0500-B5CMC 1071111

L
20 mA / 0 V ... M12 x 1, 8-pin
10 V 3.3 m LFP0500-B5DMC 1071115
1 x PNP + 1 x PNP/
NPN + 4 mA ... Round connector

M
700 mm 3.3 m LFP0700-A4DMB 1071086
20 mA / 0 V ... M12 x 1, 5-pin
10 V
G¾A
1 x PNP + 3 x PNP/

N
NPN + 4 mA ... Round connector
700 mm 3.3 m LFP0700-A5DMC 1071096
20 mA / 0 V ... M12 x 1, 8-pin
10 V
1 x PNP + 1 x PNP/

O
NPN + 4 mA ... Round connector
700 mm 3.3 m LFP0700-B4DMB 1071106
20 mA / 0 V ... M12 x 1, 5-pin
10 V
¾” NPT
1 x PNP + 3 x PNP/
NPN + 4 mA ...
20 mA / 0 V ...
10 V
Round connector
M12 x 1, 8-pin
700 mm 3.3 m LFP0700-B5DMC 1071116
P
Q
1 x PNP + 1 x PNP/ 1m LFP1000-A4BMB 1071079
NPN + 4 mA ... Round connector
1,000 mm 2m LFP1000-A4CMB 1071082
20 mA / 0 V ... M12 x 1, 5-pin
10 V 3.3 m LFP1000-A4DMB 1071087

R
G¾A
1 x PNP + 3 x PNP/ 1m LFP1000-A5BMC 1071089
NPN + 4 mA ... Round connector
1,000 mm 2m LFP1000-A5CMC 1071092
20 mA / 0 V ... M12 x 1, 8-pin
10 V 3.3 m LFP1000-A5DMC 1071097

S
8017952/2016-05-02
Subject to change without notice
F l u i d s e n s o r s | SI C K 31
T
LFP Cubic Level sensors

A Process connec-
tion
Output signal Electrical connec-
tion
Probe length Cable length Type Part no.

1 x PNP + 1 x PNP/ 1m LFP1000-B4BMB 1071099

B NPN + 4 mA ...
20 mA / 0 V ...
10 V
Round connector
M12 x 1, 5-pin
1,000 mm
2m LFP1000-B4CMB 1071102
¾” NPT

C
1 x PNP + 3 x PNP/ 1m LFP1000-B5BMC 1071109
NPN + 4 mA ... Round connector
1,000 mm 2m LFP1000-B5CMC 1071112
20 mA / 0 V ... M12 x 1, 8-pin
10 V 3.3 m LFP1000-B5DMC 1071117

D 1 x PNP + 1 x PNP/
NPN + 4 mA ...
20 mA / 0 V ...
Round connector
M12 x 1, 5-pin
2,000 mm
1m

2m
LFP2000-A4BMB

LFP2000-A4CMB
1071080

1071083
10 V

E
G¾A
1 x PNP + 3 x PNP/ 1m LFP2000-A5BMC 1071090
NPN + 4 mA ... Round connector
2,000 mm
20 mA / 0 V ... M12 x 1, 8-pin 2m LFP2000-A5CMC 1071093

F
10 V
1 x PNP + 1 x PNP/ 1m LFP2000-B4BMB 1071100
NPN + 4 mA ... Round connector
2,000 mm
20 mA / 0 V ... M12 x 1, 5-pin 2m LFP2000-B4CMB 1071103
10 V
¾” NPT
1 x PNP + 3 x PNP/ 1m LFP2000-B5BMC 1071110
NPN + 4 mA ... Round connector
2,000 mm
20 mA / 0 V ... M12 x 1, 8-pin

H
2m LFP2000-B5CMC 1071113
10 V

I Rope probe with standard amplifier


• Enclosure rating: IP 67: EN 60529
• Process temperature: –20 °C ... +100 °C

J •

Process pressure: –1 bar ... 10 bar
Housing material: Plastic PBT
Process connection Output signal Electrical connection Probe length Type Part no.

K G¾A
Round connector M12 x
1, 5-pin
1,000 mm LFP1000-E4NMB 1066785

Round connector M12 x


¾” NPT 1,000 mm LFP1000-F4NMB 1066792

L
1, 5-pin
Round connector M12 x
G¾A 2,000 mm LFP2000-E4NMB 1066786
1, 5-pin
1 x PNP + 1 x PNP/NPN
Round connector M12 x

M
¾” NPT + 4 mA ... 20 mA / 0 V ... 2,000 mm LFP2000-F4NMB 1066791
1, 5-pin
10 V
Round connector M12 x
G¾A 3,000 mm LFP3000-E4NMB 1066787
1, 5-pin

N ¾” NPT
Round connector M12 x
1, 5-pin
Round connector M12 x
3,000 mm LFP3000-F4NMB 1066790

4,000 mm LFP4000-E4NMB 1066788


1, 5-pin

O G¾A 1 x PNP + 3 x PNP/NPN


+ 4 mA ... 20 mA / 0 V ...
10 V
Round connector M12 x
1, 8-pin
4,000 mm LFP4000-E5NMC 1070139

P
1 x PNP + 1 x PNP/NPN
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 4,000 mm LFP4000-F4NMB 1066789
1, 5-pin
10 V
¾” NPT
1 x PNP + 3 x PNP/NPN

Q
Round connector M12 x
+ 4 mA ... 20 mA / 0 V ... 4,000 mm LFP4000-F5NMC 1070140
1, 8-pin
10 V

R
S
T 32 F l u i d s e n s o r s | SI C K 8017952/2016-05-02
Subject to change without notice
Level sensors LFP Cubic

Rope probe with remote amplifier


• Enclosure rating: IP 67: EN 60529
A
• Process temperature: –20 °C ... +100 °C


Process pressure: –1 bar ... 10 bar
Housing material: Plastic PBT B
C
Process connec- Output signal Electrical connec- Probe length Cable length Type Part no.
tion tion
1 x PNP + 1 x PNP/
NPN + 4 mA ... Round connector

D
1,000 mm 3.3 m LFP1000-E4DMB 1072019
20 mA / 0 V ... M12 x 1, 5-pin
10 V
G¾A
1 x PNP + 3 x PNP/
NPN + 4 mA ... Round connector
20 mA / 0 V ...
10 V
M12 x 1, 8-pin
1,000 mm 3.3 m LFP1000-E5DMC 1072020
E
1 x PNP + 1 x PNP/

F
NPN + 4 mA ... Round connector
1,000 mm 3.3 m LFP1000-F4DMB 1072090
20 mA / 0 V ... M12 x 1, 5-pin
10 V
¾” NPT
1 x PNP + 3 x PNP/
NPN + 4 mA ... Round connector
1,000 mm 3.3 m LFP1000-F5DMC 1072029
20 mA / 0 V ... M12 x 1, 8-pin
10 V

H
1 x PNP + 1 x PNP/
NPN + 4 mA ... Round connector
3,000 mm 2m LFP3000-E4CMB 1072018
20 mA / 0 V ... M12 x 1, 5-pin
10 V
G¾A
1 x PNP + 3 x PNP/
NPN + 4 mA ...
20 mA / 0 V ...
Round connector
M12 x 1, 8-pin
3,000 mm 2m LFP3000-E5CMC 1072021 I
10 V
1 x PNP + 1 x PNP/
NPN + 4 mA ...
20 mA / 0 V ...
Round connector
M12 x 1, 5-pin
3,000 mm 2m LFP3000-F4CMB 1072026
J
10 V
¾” NPT
1 x PNP + 3 x PNP/
NPN + 4 mA ... Round connector
3,000 mm 2m LFP3000-F5CMC 1072025
K
20 mA / 0 V ... M12 x 1, 8-pin

L
10 V
1 x PNP + 1 x PNP/
NPN + 4 mA ... Round connector
4,000 mm 1m LFP4000-E4BMB 1072017
20 mA / 0 V ... M12 x 1, 5-pin
G¾A
10 V
1 x PNP + 3 x PNP/
NPN + 4 mA ... Round connector
M
4,000 mm 1m LFP4000-E5BMC 1072022

N
20 mA / 0 V ... M12 x 1, 8-pin
10 V
1 x PNP + 1 x PNP/
NPN + 4 mA ... Round connector
4,000 mm 1m LFP4000-F4BMB 1072023

¾” NPT
20 mA / 0 V ...
10 V
1 x PNP + 3 x PNP/
M12 x 1, 5-pin
O
NPN + 4 mA ... Round connector

P
4,000 mm 1m LFP4000-F5BMC 1072024
20 mA / 0 V ... M12 x 1, 8-pin
10 V

Q
R
S
8017952/2016-05-02
Subject to change without notice
F l u i d s e n s o r s | SI C K 33
T
LFP Cubic Level sensors

A Type code

Probe length in mm

B
0025 Without probe
0200 200 mm (steps of 10 mm for rod probe; steps of 1,000 mm for rope probe)
4000 4,000 mm
Process connection/probe design

C
A G ¾ A / exchangeable rod probe, 1.4404 / 316L; 100°C; 10 bar
B ¾” NPT / exchangeable rod probe, 1.4404/316L; 100°C; 10 bar
E G ¾ A / rope probe 3 mm, 1.4404 / 316L; 100°C; 10 bar
F ¾” NPT / rope probe 3 mm, 1.4404 / 316L; 100°C; 10 bar
Housing/display/electrical connection

D 4 Plastic housing with display / connector M12 x 1, 5-pin


5 Plastic housing with display / connector M12 x 1, 8-pin
Application type
N Standard

E
B Remote amplifier / cable length 1 m
C Remote amplifier / cable length 2 m
D Remote amplifier / cable length 3.3 m
Signal output

F
M 4 mA … 20 mA / 0 V … 10 V, configurable
Switching output
B 1 x PNP + 1 x PNP/NPN
C 1 x PNP + 3 x PNP/NPN
Device type
Standard
L PWIS-cleaned

H LFP - M

Not all variations of the type code can be combined!

I Max. probe length (mm)


Coaxial cable length (mm) Foam mode inactive Foam mode active

J 1,000

2,000
4,000

3,000
2,000

1,500

3,300 1,000 500

K
L
M
N
O
P
Q
R
S
T 34 F l u i d s e n s o r s | SI C K 8017952/2016-05-02
Subject to change without notice
Level sensors LFP Cubic

Dimensional drawings (Dimensions in mm (inch))


A
Rod probe
50
(1.97)
B
C

(1.30)
33
(4.09)

(1.69)
104

43
(4.96)
(2.80)

126
D
71
32
(1.26)

(0.87)
36

22
(1.42) M12x1

(0.59)
(0.87)

15
22

5 G 3/4 A
(0.20) 3/4" NPT
IA

IA
G 3/4 A
3/4" NPT
L

L
M

M
(
7
0.28) H
20

IAE
I
IAE

( 0.79)

monoprobe with coaxial tube

1 M: measuring range
2 L: Probe length
J
K
3 IA: Inactive area at process connection 25 mm (0.98”)
4 IAE: Inactive area at probe end 10 mm (0.39”)

L
M
N
O
P
Q
R
S
8017952/2016-05-02
Subject to change without notice
F l u i d s e n s o r s | SI C K 35
T
LFP Cubic Level sensors

A Rope probe
120
(m min (4.72)

B
in . R
. R 50
1.9
7)

(0.87)

(1.77)
22

45
36
(1.42)
(3.27)
83

D
G 3/4 A
(4.76)
121
3/4" NPT

IA
5

E 36
(1.42)
(0.20)

F
0.26)

L
6.5

M
(0.55)

7
14

(0.28)
(

40
(1.58)

70
(2.76)

H 43

IAE
(1.69)
M12x1

0.20)

I
5
(
(2.87)
(1.97)

(1.58)
73
50

40
J C

K
33
(1.30) C: Cable length
M: Measuring range
L: Probe length
IA: Inactive area at process connection

L All dimensions in mm (inch)


20 mm (0.79") / 40 mm (1.58")
IAE: Inactive area at probe end 10 mm (0.39")

M
N
O
P
Q
R
S
T 36 F l u i d s e n s o r s | SI C K 8017952/2016-05-02
Subject to change without notice
Level sensors LFP Cubic

Remote amplifier
50
A
(1.97)

(1.69)
(4.09)
104

43
C

(1.30)
(2.80)

33
71
D
36
(1.42) M12x1
(0.87)
22

5 G 3/4 A
E
IA

(0.20) 3/4" NPT

(
3
0.11) 3
F
L

H
I
(3.93)
100

(0.47)
12

M6
J
24

K
IAE

( 0.94)

1 M: measuring range

L
2 L: Probe length
3 IA: Inactive area at process connection 25 mm (0.98”)
4 IAE: Inactive area at probe end 10 mm (0.39”)

M
N
O
P
Q
R
S
8017952/2016-05-02
Subject to change without notice
F l u i d s e n s o r s | SI C K 37
T
LFP Cubic Level sensors

A Connection type

B
C
 


   
D

 
 

E
1 L+: Supply voltage, brown 1 L+: Supply voltage

F 2 QA: Analog current-/voltage output, white


3 M: Ground, reference ground for current-/voltage output, blue
4 C/Q1: Switching output 1, PNP/IO-Link-communication, black
2 Q2: Switching output 2, PNP/NPN
3 M: Ground, reference ground for current-/voltage output
4 C/Q1: Switching output 1, PNP/IO-Link-communication
5 Q2: Switching output 2, PNP/NPN, grey 5 Q3: Switching output 3, PNP/NPN
6 Q4: Switching output 4, PNP/NPN
7 QA: Analog current-/voltage output
8 No function

H Accessories
Mounting systems
I Device protection (mechanical)
Protective housings and protective pipes

J Brief description Type Part no.


Coaxial probe for LFP with process connection G ¾, process connection of coaxial

K
LFPCT-0200G1 2068141
probe G ¾, material 1.4571/316TI, for probe length 200 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0200N1 2068165
probe ¾” NPT, material 1.4571/316TI, for probe length 200 mm

L
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0300G1 2068142
probe G ¾, material 1.4571/316TI, for probe length 300 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0300N1 2068166
probe ¾” NPT, material 1.4571/316TI, for probe length 300 mm

M Coaxial probe for LFP with process connection G ¾, process connection of coaxial
probe G ¾, material 1.4571/316TI, for probe length 400 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0400G1 2068143

LFPCT-0400N1 2068167

N
probe ¾” NPT, material 1.4571/316TI, for probe length 400 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0500G1 2068144
probe G ¾, material 1.4571/316TI, for probe length 500 mm
Illustration may Coaxial probe for LFP with process connection G ¾, process connection of coaxial

O
differ LFPCT-0500N1 2068168
probe ¾” NPT, material 1.4571/316TI, for probe length 500 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0600G1 2068145
probe G ¾, material 1.4571/316TI, for probe length 600 mm

P
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0600N1 2068169
probe ¾” NPT, material 1.4571/316TI, for probe length 600 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0700G1 2068146
probe G ¾, material 1.4571/316TI, for probe length 700 mm

Q Coaxial probe for LFP with process connection G ¾, process connection of coaxial
probe ¾” NPT, material 1.4571/316TI, for probe length 700 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0700N1 2068170

LFPCT-0800G1 2068147

R
probe G ¾, material 1.4571/316TI, for probe length 800 mm

S
T 38 F l u i d s e n s o r s | SI C K 8017952/2016-05-02
Subject to change without notice
Level sensors LFP Cubic

Brief description
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
Type

LFPCT-0800N1
Part no.

2068171
A
probe ¾” NPT, material 1.4571/316TI, for probe length 800 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
probe G ¾, material 1.4571/316TI, for probe length 900 mm
LFPCT-0900G1 2067507 B
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-0900N1 2068172

C
probe ¾” NPT, material 1.4571/316TI, for probe length 900 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-1000G1 2065702
probe G ¾, material 1.4571/316TI, for probe length 1000 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial

D
LFPCT-1000N1 2068173
probe ¾” NPT, material 1.4571/316TI, for probe length 1000 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-1100G1 2068148
probe G ¾, material 1.4571/316TI, for probe length 1100 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
probe ¾” NPT, material 1.4571/316TI, for probe length 1100 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-1100N1 2068174
E
LFPCT-1200G1 2068149
probe G ¾, material 1.4571/316TI, for probe length 1200 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
probe ¾” NPT, material 1.4571/316TI, for probe length 1200 mm
LFPCT-1200N1 2068175 F
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-1300G1 2068150
probe G ¾, material 1.4571/316TI, for probe length 1300 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-1300N1 2068176
probe ¾” NPT, material 1.4571/316TI, for probe length 1300 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
probe G ¾, material 1.4571/316TI, for probe length 1400 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-1400G1

LFPCT-1400N1
2068151

2068177
H
probe ¾” NPT, material 1.4571/316TI, for probe length 1400 mm

I
Illustration may Coaxial probe for LFP with process connection G ¾, process connection of coaxial
differ LFPCT-1500G1 2068152
probe G ¾, material 1.4571/316TI, for probe length 1500 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-1500N1 2068178
probe ¾” NPT, material 1.4571/316TI, for probe length 1500 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
probe G ¾, material 1.4571/316TI, for probe length 1600 mm
LFPCT-1600G1 2068153 J
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-1600N1 2068179
probe ¾” NPT, material 1.4571/316TI, for probe length 1600 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
probe G ¾, material 1.4571/316TI, for probe length 1700 mm
LFPCT-1700G1 2068154 K
L
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-1700N1 2068180
probe ¾” NPT, material 1.4571/316TI, for probe length 1700 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-1800G1 2068155
probe G ¾, material 1.4571/316TI, for probe length 1500 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
probe ¾” NPT, material 1.4571/316TI, for probe length 1800 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-1800N1 2068181
M
LFPCT-1900G1 2068156
probe G ¾, material 1.4571/316TI, for probe length 1900 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
probe ¾” NPT, material 1.4571/316TI, for probe length 1900 mm
LFPCT-1900N1 2068182 N
Coaxial probe for LFP with process connection G ¾, process connection of coaxial

O
LFPCT-2000G1 2065703
probe G ¾, material 1.4571/316TI, for probe length 2000 mm
Coaxial probe for LFP with process connection G ¾, process connection of coaxial
LFPCT-2000N1 2068183
probe ¾” NPT, material 1.4571/316TI, for probe length 2000 mm

Flanges
Flange plates
P
Brief description Type Part no.
Q
Process connection adapter G ¾ to G1 BEF-HA-G1BSP1-LFP1 2067603

R
S
8017952/2016-05-02
Subject to change without notice
F l u i d s e n s o r s | SI C K 39
T
LFP Cubic Level sensors

A Weld-in flange

Brief description Type Part no.

B Weld-in flange G ¾” BEF-FL-GEWG34-LFP1 2082150

C Terminal and alignment brackets

D
Alignment brackets

Brief description Type Part no.

E 1 piece, Centering for bypass- and immersion tube installation with diameter
40 mm ... 100 mm, PTFE
BEF-FL-BYRD40-LFP1 2059612

F Connection systems
Modules and gateways
Fieldbus modules

Brief description Type Part no.

H
Number of IO-Link ports: 4; Communication mode: COM1/COM2; IO-Link version:
IO-Link V1.0; Switching input: PNP; Supply voltage Vs, IO-Link ports: DC 24 V; Current
loading: 800 mA; Data transmission rate: Max. 12 MBaud, Autobaud; Address space
occupation: 1 bis 126; Connection type: Connector M12; Connection type, IO-Link IOLSHPB-P3104R01 6039728

I
ports: Connector M12, 5-pin; Suppyl voltage Vs, module: DC 18 V ... 30 V; Power con-
sumption: Typ. 75 mA / max. 100 mA (at UL with DC 24 V), Typ. 25 mA + sensor current
/ max. 80

J
K Plug connectors and cables
Connecting cables with female connector

L Brief description Type Part no.

Head A: female connector, M12, 5-pin, straight

M Illustration may
Head B: cable
Cable: PVC, unshielded, 2 m
DOL-1205-G02M 6008899

differ

N Head A: female connector, M12, 5-pin, straight


Head B: cable
Cable: drag chain use, PUR, halogen-free, unshielded, 2 m
DOL-1205-G02MC 6025906

O Head A: female connector, M12, 5-pin, straight


Head B: cable DOL-1205-G05M 6009868
Cable: PVC, unshielded, 5 m

P
Illustration may
differ
Head A: female connector, M12, 5-pin, straight
Head B: cable DOL-1205-G05MC 6025907

Q Cable: drag chain use, PUR, halogen-free, unshielded, 5 m

Head A: female connector, M12, 5-pin, straight

R Illustration may
differ
Head B: cable
Cable: PVC, unshielded, 10 m
DOL-1205-G10M 6010544

S
T 40 F l u i d s e n s o r s | SI C K 8017952/2016-05-02
Subject to change without notice
Level sensors LFP Cubic

Brief description
Head A: female connector, M12, 5-pin, straight
Type Part no.
A
Head B: cable DOL-1205-G10MC 6025908
Cable: drag chain use, PUR, halogen-free, unshielded, 10 m
B
Head A: female connector, M12, 5-pin, angled

Illustration may
Head B: cable
Cable: PVC, unshielded, 2 m
DOL-1205-W02M 6008900
C
differ
Head A: female connector, M12, 5-pin, angled
Head B: cable
Cable: drag chain use, PUR, halogen-free, unshielded, 2 m
DOL-1205-W02MC 6025909 D
Head A: female connector, M12, 5-pin, angled
Head B: cable DOL-1205-W05M 6009869
E
Cable: PVC, unshielded, 5 m

F
Illustration may
differ
Head A: female connector, M12, 5-pin, angled
Head B: cable DOL-1205-W05MC 6025910
Cable: drag chain use, PUR, halogen-free, unshielded, 5 m

Head A: female connector, M12, 5-pin, angled

Illustration may
differ
Head B: cable
Cable: PVC, unshielded, 10 m
DOL-1205-W10M 6010542
H
I
Head A: female connector, M12, 5-pin, angled
Head B: cable DOL-1205-W10MC 6025911
Cable: drag chain use, PUR, halogen-free, unshielded, 10 m

J
Head A: female connector, M12, 8-pin, straight
Head B: cable DOL-1208-G02MA 6020633
Cable: PVC, shielded, 2 m
Head A: female connector, M12, 8-pin, straight
Head B: cable
Cable: drag chain use, PUR, halogen-free, unshielded, 2 m
DOL-1208-G02MC 6035620
K
Head A: female connector, M12, 8-pin, straight
Head B: cable
Cable: PVC, shielded, 5 m
Head A: female connector, M12, 8-pin, straight
DOL-1208-G05MA 6020993
L
M
Head B: cable DOL-1208-G05MC 6035621
Cable: drag chain use, PUR, halogen-free, unshielded, 5 m
Head A: female connector, M12, 8-pin, straight
Head B: cable DOL-1208-G10MA 6022152
Cable: PVC, shielded, 10 m
Head A: female connector, M12, 8-pin, straight
N
Head B: cable DOL-1208-G10MC 6035622
Cable: drag chain use, PUR, halogen-free, unshielded, 10 m
Head A: female connector, M12, 8-pin, angled
O
Head B: cable DOL-1208-W02MA 6020992

P
Cable: PVC, shielded, 2 m
Head A: female connector, M12, 8-pin, angled
Head B: cable DOL-1208-W02MC 6035623

Q
Cable: PUR, unshielded, 2 m
Head A: female connector, M12, 8-pin, angled
Head B: cable DOL-1208-W05MA 6021033
Cable: PVC, shielded, 5 m

R
S
8017952/2016-05-02
Subject to change without notice
F l u i d s e n s o r s | SI C K 41
T
LFP Cubic Level sensors

A Brief description
Head A: female connector, M12, 8-pin, angled
Type Part no.

Head B: cable DOL-1208-W05MC 6035624

B Cable: PUR, unshielded, 5 m


Head A: female connector, M12, 8-pin, angled
Head B: cable DOL-1208-W10MC 6035625

C
Cable: PUR, unshielded, 10 m

D Further accessories
Spare parts

E Brief description
Spare probe for LFP Cubic, probe length 1,000 mm, material
Type

BEF-ER-SN1000-LFPC
Part no.

2065700
1.4404/316L, diameter 7 mm

F Illustration may
differ
Spare probe for LFP Cubic, probe length 2,000 mm, material
1.4404/316L, diameter 7 mm
BEF-ER-SN2000-LFPC 2065701

Spare cable probe for LFP Cubic, length 2 m BEF-ER-SS2000-LFPC 2078194


Spare cable probe for LFP Cubic, length 4 m BEF-ER-SS4000-LFPC 2078195
Spare cable probe for LFP Cubic, length 6 m BEF-ER-SS6000-LFPC 2082147

H Spare titan probe for LFP Cubic, length 1 m


Spare titan probe for LFP Cubic, length 2 m
BEF-ER-TS1000-LFPC
BEF-ER-TS2000-LFPC
2081042
2081043

I
Spare coaxial cable for LFP Cubic, separate amplifier, length 1 m CBL-CX-001000-LFPC 2077792
Spare coaxial cable for LFP Cubic separate amplifier, length 2 m CBL-CX-002000-LFPC 2077793
Illustration may
Spare coaxial cable for LFP Cubic separate amplifier, length 3.3 m CBL-CX-003300-LFPC 2077794

J
differ

K
L
M
N
O
P
Q
R
S
T 42 F l u i d s e n s o r s | SI C K 8017952/2016-05-02
Subject to change without notice
SERVICES

REGISTER AT WWW.SICK.COM TODAY AND A


ENJOY ALL THE BENEFITS
B
m Select products, accessories, documentation and soft-

m
ware quickly and easily.
Create, save and share personalized wish lists.
C
D
m View the net price and date of delivery for every product.
m Requests for quotation, ordering and delivery tracking
made easy.
m
m
Overview of all quotations and orders.
Direct ordering: submit even very complex orders in
E
F
moments.
m View the status of quotations and orders at any time.
Receive e-mail notifications of status changes.
m Easily repeat previous orders.
m Conveniently export quotations and orders to work with
your systems.
H
I
J
SERVICES FOR MACHINES AND SYSTEMS: SICK LifeTime Services
Our comprehensive and versatile LifeTime Services are the perfect addition to the comprehensive range of products from
SICK. The services range from product-independent consulting to traditional product services.
K
L
Consulting and design
Safe and professional
M
Product and system support
Reliable, fast and on-site N
Verification and optimization O
Safe and regularly inspected

P
Upgrade and retrofits
Easy, safe and economical
Q
Training and education
Practical, focused and professional R
S
8017952/2016-05-02
Subject to change without notice
F l u i d s e n s o r s | SI C K 43
T
SICK AT A GLANCE
8017952/2016-05-02 ∙ 9MS/ITL ∙ Pre USmod en45

SICK is a leading manufacturer of intelligent sensors and sensor solutions for industrial applications. With
more than 7,400 employees and over 50 subsidiaries and equity investments as well as numerous repre-
sentative offices worldwide, we are always close to our customers. A unique range of products and services
creates the perfect basis for controlling processes securely and efficiently, protecting individuals from
accidents and preventing damage to the environment.

We have extensive experience in various industries and understand their processes and requirements.
With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe,
Asia and North America, system solutions are tested and optimized in accordance with customer specifica-
tions. All this makes us a reliable supplier and development partner.

Comprehensive services round out our offering: SICK LifeTime Services provide support throughout the
machine life cycle and ensure safety and productivity.

For us, that is “Sensor Intelligence.”

Worldwide presence:

Australia, Austria, Belgium, Brazil, Canada, Chile, China, Czech Republic, Denmark, Finland, France,
Germany, Great Britain, Hungary, India, Israel, Italy, Japan, Malaysia, Mexico, Netherlands, New Zealand,
Norway, Poland, Romania, Russia, Singapore, Slovakia, Slovenia, South Africa, South Korea, Spain,
Sweden, Switzerland, Taiwan, Thailand, Turkey, United Arab Emirates, USA, Vietnam.

Detailed addresses and additional representatives - www.sick.com

SICK AG | Waldkirch | Germany | www.sick.com


P R O D U C T I N FO R M AT I O N
LFV200
THE POINT LEVEL SENSOR FOR ALL KIND OF LIQUIDS

Level sensors
GOOD VIBRATIONS

The benefits at a glance


•• IO-Link is integrated
•• Time saved through easy,
rapid installation and com-
missioning without medium
calibration
•• Flexibility thanks to the vari-
ous installation options – lat-
erally, from above or below,
in pipelines from DN 25 (1”)
etc.
•• User friendly: Sensors can be
tested while installed
•• High degree of reliability,
regardless of installation
position and liquid type
•• Cost efficiency through main-
tenance-free non-contact
design
•• Certified according to EHEDG
(depending on type), WHG

THE LFV200 WITH IO-LINK IS GIVING FRESH IMPETUS TO POINT


LEVEL MEASUREMENT
Reliable point level measurement – This is what defines the vibrating level switches from the LFV200
product family. The level sensors, which can be used in almost any application, are available in compact or
extended pipe variants and expand the data usage possibilities with their integrated IO-Link.

2 FLUID SENSORS | SICK 8012597/2019-02-08


Subject to change without notice
Operating principle
LFV200 detects the presence of liquids through vibrational changes to the tuning fork. These changes are dependent upon how
much liquid is covering the tuning fork. The switching point of the limit to be measured is determined by the installation location
and position and the sensor length. Teaching-in of the liquid to be measured is not required.

Sensor head with electronic evaluat-


ing system and IO-Link interface

Piezoceramic elements
adjust the tuning forks to
A large variety of process resonance frequency
connections available

Alignment
markings Extended pipe
variant

If the liquid covers the


tuning fork, the frequency
is reduced

Compact
variant

- See product part from page 6


Integrated
temperature sensor If the frequency falls below
a certain limit, an error is
output
Paddle with piezoceramic
elements

Fields of application
Point level measurements take many different forms and take meter in the supply tank. On top of this, the LFV200 functions
place in high numbers. The LFV200 vibrating level switches can independently of the liquid and is wear- and maintenance-free.
contribute to overfill protection, supply monitoring or process Furthermore, the hygienic design of the sensor can be easily
control, as well as to low-level monitoring (e.g. for pump dry-run cleaned.
protection). Predefined levels are recorded down to the milli-

Point level measurement Point level measurement Overfill protection Low-level monitoring

8012597/2019-02-08 FLUID SENSORS | SICK 3


Subject to change without notice
LFV200 IO-Link

IO-Link KEEPS COMMUNICATION FLOWING


IO-Link offers new options for communication between the system control
and field level. This is a crucial aspect, as networked production and control
processes in complex machine environments are key to the industrial future
and are what is making Industry 4.0 possible in the first place.

The world’s first standardized IO technology (according to them with the process controller. The result: Clear cost and
IEC 61131-9) means sensors can play an active role in end- process optimization throughout the entire supply chain – and
to-end automation networks. They record real operational a decisive step toward an Industry 4.0 approach.
statuses, turn these into digital data, and independently share

More application possibilities


The influence of users on the switching behavior of vibrating Continuous condition monitoring provides information on tem-
level switches is usually limited. With its IO-Link interface, the perature as well as density- and viscosity-proportional signals.
LFV200 breaks through these limits and makes possible a sig- This means that liquids can be differentiated from one another
nificantly larger, more individual application spectrum through and expands diagnosis options.
its adjustable switching frequency.

Determining different liquids Coat detection

Adherence

Water Emulsion Emulsion Emulsion

4 LFV200 | SICK 8012597/2019-02-08


Subject to change without notice
IO-Link LFV200

MORE INFORMATION DEPTH


Via its integrated IO-Link interface, the LFV200 vibrating level switch shares the collected data in the auto-
mation network. In addition to the standard functions and pure level measurement, other valuable infor-
mation is also available for evaluation and further processing.

Machine level

In the event of a fault, the IO-Link inter-


face of the LFV200 provides important
Control level
information about extreme measure-
ments in real time. This makes it possi-
ble to take countermeasures quickly in
order to prevent damage being caused to
the equipment (predictive maintenance).

IO-Link master for simplified


programming using specific
function blocks

-  www.sick.com
IO-Link ▸ IO-Link – The new form of
communication on the sensor level
LFV200 sensor
signal Direct link

Smart Sensors ▸ Downloads


▸ SMART SENSORS SUPPLIERS OF
The advantages of the LFV200 INFORMATION FOR INDUSTRY 4.0
Direct link
Medium detection
Medium determination
Temperature information
More diagnostic options

8012597/2019-02-08 LFV200 | SICK 5


Subject to change without notice
LFV200 Level sensors

A
THE POINT LEVEL SENSOR FOR ALL KINDS OF
B LIQUIDS
C Product description

D The vibrating level switch of the LFV200


product family detects the pre-defined
levels in liquid systems with maximum
steel make the LFV200, in combination
with aseptic process connections, the
first choice for applications even with

E precision. Whether indicating that a con-


tainer has reached its maximum fill level
(overfill protection) or that it is empty
the strictest hygiene requirements. With
the LFV230, extended pipe variants up
to 1,200 mm are available. With IO-Link,

F
or used in pipes to prevent the pumps the oscillation frequency, amplitude and
from running dry, the LFV200 works temperature of the sensor can be read
with all liquids and is wear- and mainte- out in addition to the switching signal,
nance-free. A high surface quality and which enables extended diagnostics and
the rugged tuning fork made of stainless predictive maintenance.

H At a glance
• Commissioning without container • Pipe extension up to 1,200 mm
filling or medium calibration • Hygienic designs with polished sur-

I • Immune to deposit formation


• Process temperature up to 150 °C
face, CIP- and SIP-capable
• Housing made of 316L stainless steel
• Two electrical output versions and • Very high repeatability

J IO-Link available

K
Your benefits
• Universal and reliable technology for • Maintenance-free system
nearly all liquids and applications • Sensors can be tested while installed

L • Can be used in containers and pipes


regardless of the mounting situation
• Easy installation and commissioning,
• Frequency, amplitude and tempera-
ture of the sensor can be read out via
IO-Link

M no medium calibration necessary


• Easy operation and system integra-
tion
• Extended pipe variants for more
flexibility

N
O
P
Q Additional information
Detailed technical data����������������������� 7

R
Type code����������������������������������������������8
Ordering information����������������������������9
Dimensional drawings������������������������16 -- www.sick.com/LFV200

S Recommended accessories��������������17 For more information, simply enter the link or scan the QR code and get direct access to
technical data, CAD design models, operating instructions, software, application examples, and
much more.

T 6 F l u i d s e n s o r s | SI C K 8012597/2019-02-08
Subject to change without notice
Level sensors LFV200

Detailed technical data


Features
A
Medium Fluids
LFV200 LFV230
B
C
Measurement Switch
Probe length 67 mm 80 mm ... 1,200 mm
115 mm

D
Process pressure –1 bar ... +64 bar
Process temperature –40 °C ... +100 °C
–40 °C ... +150 °C (depending on type)
Fill material density
E
0.7 g/cm³ ... 2.5 g/cm³
WHG approval l (depending on type)
IO-Link l (depending on type)
EHEDG approval l (depending on type)
F
Performance
Accuracy of sensor element ± 2 mm
Reproducibility ≤ 1 mm
Viscosity
Resolution
0.1 mPas ... 10,000 mPas
≤ 1 mm H
Response time 500 ms

Mechanics I
J
LFV200 LFV230
Wetted parts Stainless steel 1.4404 (Ra ≤ 0,8 µm optional)
Process connection See type code
Housing material Stainless steel 1.4404, PEI
K
Electronics

Supply voltage
Non-contact switch
20 V AC/DC ... 253 V AC/DC
Tranistor output PNP (with IO-Link)
9.6 V DC ... 35 V DC
L
M
18 V DC ... 30 V DC (IO-Link)
Residual ripple – ≤ 5 Vpp
Power consumption ≤ 4.2 mA < 10 mA
Initialization time
VDE protection class 1
<3s
l
<2s

N
VDE protection class 2 –

O
l
Electrical connection Valve plug DIN 43650 / M12 round connector x 1, 4-pin (depending on type)
Hysteresis 2 mm
Signal voltage HIGH
Signal voltage LOW


Vs –3 V
0 V +- 1 V P
Output current – < 250 mA
Inductive load
Capacitive load
≤1H
100 nF
Q
R
Enclosure rating IP65 / IP67 (depending on type)
Temperature drift 0.03 mm/K

S
8012597/2019-02-08
Subject to change without notice
F l u i d s e n s o r s | SI C K 7
T
LFV200 Level sensors

A Ambient data
Ambient operating temperature –40 °C ... +70 °C

B Ambient storage temperature –40 °C ... +80 °C

Type code
C Certification
XX None

D
XA Overfill protection in acc. with WHG (German Federal Water Act)
Execution/Process temperature
S Standard / –40 °C ... +100 °C
T Expanded / –40 °C ... +150 °C
H Hygiene applications / –40 °C ... +150 °C

E Process connection/Material
GH G ½, DIN3852-A, PN 64 / 316L
NH ½“ NPT, ASME B1.20.1, PN 64 / 316L
GB G ¾ A, PN 64 / 316L

F
NB ¾“ NPT, PN 64 / 316L
GA G 1 A, PN 64 / 316L
NA 1“ NPT, PN 64 / 316L
CL Tri-clamp 1“, PN 16, L, Ra < 0.8 µm
CN Tri-clamp 2“, PN 16, L, Ra < 0.8 µm
RL Conical adapter DN 25, DIN 11851 with coupling nut PN 40 / 316L, Ra < 0.8 μm
RM Conical adapter DN 40, DIN 11851 with coupling nut PN 40 / 316L, Ra < 0.8 μm
RN Conical adapter DN 50, DIN 11851 with coupling nut PN 40 / 316L, Ra < 0.8 μm
GP G ¾ A, PN 64 / 316L, Ra < 0.8 µm

H NP ¾“ NPT, PN 64 / 316L, Ra < 0.8 µm


GL G 1 A, PN 64 / 316L, Ra < 0.8 µm
NL 1“ NPT, PN 64 / 316L, Ra < 0.8 µm
CM Tri-clamp 1 ½“, PN 16, L, Ra < 0.8 µm

I RR SMS DN 38, PN 6, 316L, Ra < 0.8 µm


PW Aseptic connection with grooved cap nut, F 40, DN 25, 316L, Ra < 0.8 µm
R3 Thread R ¾, PN 64, 316L, EN10226-1
Electronics

J
C Contact-free switch, 20 … 253 V AC/DC
T PNP transistor output, 9.6 … 35 V DC
I PNP transistor output with IO-Link, 18 … 30 V DC
Housing
P 1.4404

K Electrical connection / Enclosure rating


M M12 x 1 / IP67
R DIN 43650 including male connector / IP65
Measuring point identification plate

L None
L Fork length 115 mm

M LFV200 - P

Not all variants of the type code can be combined!

N
O
P
Q
R
S
T 8 F l u i d s e n s o r s | SI C K 8012597/2019-02-08
Subject to change without notice
Level sensors LFV200

Certification
XX None
XA Overfill protection in acc. with WHG (German Federal Water Act)
A
B
Execution/Process temperature
S Standard / –40 °C ... +100 °C
T Expanded / –40 °C ... +150 °C
H Hygiene applications / –40 °C ... +150 °C
Process connection/Material
GB G ¾ A, PN 64 / 316L
NB ¾“ NPT, PN 64 / 316L
GA G 1 A, PN 64 / 316L
C
NA 1“ NPT, PN 64 / 316L

D
CL Tri-clamp 1“, PN 16, L, Ra < 0.8 µm
CN Tri-clamp 2“, PN 16, L, Ra < 0.8 µm
RL Conical adapter DN 25, DIN 11851 with coupling nut PN 40 / 316L, Ra < 0.8 μm
RM Conical adapter DN 40, DIN 11851 with coupling nut PN 40 / 316L, Ra < 0.8 μm

E
RN Conical adapter DN 50, DIN 11851 with coupling nut PN 40 / 316L, Ra < 0.8 μm
R3 Thread R ¾, PN 64, 316L, EN10226-1
Electronics
C Contact-free switch, 20 … 253 V AC/DC
T PNP transistor output, 9.6 … 35 V DC
I PNP transistor output with IO-Link, 18 … 30 V DC
Housing
P 1.4404
F
Electrical connection / Enclosure rating
M M12 x 1 / IP67
R DIN 43650 including male connector / IP65
Length 80 mm to 1,200 mm

LFV 230 - P
H
I
Not all variants of the type code can be combined!

Ordering information
LFV200
• Enclosure rating: IP65
J
• Process pressure: –1 bar ... +64 bar


Housing material: Stainless steel 1.4404, PEI
Electrical connection: Valve plug DIN 43650
K
L
Process connection Output signal Process temperature Probe length WHG Type Part no.
approval
Triclamp 1’’ (PN 16, 316L, Non-contact
–40 °C ... +150 °C 67 mm l LFV200-XAHCLCPV 6036548
Ra<0.8μm) switch
Triclamp 2’’ (PN 16, 316L,
Ra < 0.8μm)
Non-contact
switch
–40 °C ... +150 °C 67 mm l LFV200-XAHCNCPV 6036549 M
Conical coupling DN 25 acc.

N
to DIN 11851 with Non-contact
–40 °C ... +150 °C 67 mm l LFV200-XAHRLCPV 6036550
Union nut (PN 40, 316L, Ra switch
< 0.8µm)
Conical coupling DN 40 acc.
To DIN 11851 with union
nut (PN 40, 316L, Ra <
0.8µm)
Non-contact
switch
–40 °C ... +150 °C 67 mm l LFV200-XAHRMCPV 6036551
O
P
Conical coupling DN 50 acc.
to DIN 11851 with Non-contact
–40 °C ... +150 °C 67 mm l LFV200-XAHRNCPV 6036552
Union nut (PN 40, 316L, Ra switch
< 0.8µm)

G 1 A PN 64
Non-contact
switch
–40 °C ... +100 °C
67 mm
115 mm
l
l
LFV200-XASGACPV
LFV200-XASGACPVL
6036377
6037301 Q
Non-contact

R
G ¾ A PN 64 –40 °C ... +100 °C 67 mm l LFV200-XASGBCPV 6036375
switch
Non-contact
G ½ A PN 64 –40 °C ... +100 °C 67 mm l LFV200-XASGHCPV 6054121
switch

S
8012597/2019-02-08
Subject to change without notice
F l u i d s e n s o r s | SI C K 9
T
LFV200 Level sensors

A Process connection Output signal Process temperature Probe length WHG


approval
Type Part no.

Non-contact 67 mm l LFV200-XASNACPV 6036378

B 1” NPT PN 64

¾” NPT PN 64
switch
Non-contact
–40 °C ... +100 °C

–40 °C ... +100 °C


115 mm

67 mm
l

l
LFV200-XASNACPVL

LFV200-XASNBCPV
6037302

6036376
switch

C G 1 A PN 64
Non-contact
switch
–40 °C ... +150 °C
67 mm
115 mm
l
l
LFV200-XATGACPV
LFV200-XATGACPVL
6036381
6037303

D
Transistor output
–40 °C ... +150 °C 67 mm l LFV200-XATGATPV 6042041
PNP
Non-contact 67 mm l LFV200-XATGBCPV 6036379
–40 °C ... +150 °C
switch 115 mm LFV200-XATGBCPVL 6058134

E
G ¾ A PN 64 l
Transistor output
–40 °C ... +150 °C 67 mm l LFV200-XATGBTPV 6041094
PNP
67 mm l LFV200-XATNACPV 6036382

F
Non-contact
1” NPT PN 64 –40 °C ... +150 °C
switch 115 mm l LFV200-XATNACPVL 6037304
Non-contact
¾” NPT PN 64 –40 °C ... +150 °C 67 mm l LFV200-XATNBCPV 6036380
switch
Triclamp 1’’ (PN 16, 316L, Non-contact
–40 °C ... +150 °C 67 mm – LFV200-XXHCLCPV 6036543
Ra<0.8μm) switch
Triclamp 2’’ (PN 16, 316L, Non-contact
–40 °C ... +150 °C 67 mm – LFV200-XXHCNCPV 6036544

H
Ra < 0.8μm) switch
Conical coupling DN 25 acc.
to DIN 11851 with Non-contact
–40 °C ... +150 °C 67 mm – LFV200-XXHRLCPV 6036545
Union nut (PN 40, 316L, Ra switch

I < 0.8µm)
Conical coupling DN 40 acc.
To DIN 11851 with union Non-contact
–40 °C ... +150 °C 67 mm – LFV200-XXHRMCPV 6036546

J
nut (PN 40, 316L, Ra < switch
0.8µm)
Conical coupling DN 50 acc.
to DIN 11851 with Non-contact
–40 °C ... +150 °C 67 mm – LFV200-XXHRNCPV 6036547

K Union nut (PN 40, 316L, Ra


< 0.8µm)
switch

Non-contact 67 mm – LFV200-XXSGACPV 6036369


–40 °C ... +100 °C

L
switch 115 mm – LFV200-XXSGACPVL 6037305
G 1 A PN 64
Transistor output
–40 °C ... +100 °C 67 mm – LFV200-XXSGATPV 6037759
PNP

M Non-contact 67 mm – LFV200-XXSGBCPV 6036367


–40 °C ... +100 °C
switch 115 mm – LFV200-XXSGBCPVL 6051048
G ¾ A PN 64
Transistor output
–40 °C ... +100 °C 67 mm – LFV200-XXSGBTPV 6039206

N
PNP
Non-contact
–40 °C ... +100 °C 67 mm – LFV200-XXSGHCPV 6048866
switch
G ½ A PN 64
Transistor output

O
–40 °C ... +100 °C 67 mm – LFV200-XXSGHTPV 6049356
PNP
Non-contact 67 mm – LFV200-XXSNACPV 6036370
–40 °C ... +100 °C
switch 115 mm – LFV200-XXSNACPVL 6037306

P
1” NPT PN 64
Transistor output
–40 °C ... +100 °C 67 mm – LFV200-XXSNATPV 6040875
PNP
Non-contact

Q
–40 °C ... +100 °C 67 mm – LFV200-XXSNBCPV 6036368
switch
¾” NPT PN 64
Transistor output
–40 °C ... +100 °C 67 mm – LFV200-XXSNBTPV 6048611
PNP

R
Non-contact
–40 °C ... +100 °C 67 mm – LFV200-XXSNHCPV 6048865
switch
½’’ NPT PN 64
Transistor output
–40 °C ... +100 °C 67 mm – LFV200-XXSNHTPV 6049697
PNP

S
T 10 F l u i d s e n s o r s | SI C K 8012597/2019-02-08
Subject to change without notice
Level sensors LFV200

Process connection Output signal Process temperature Probe length WHG


approval
Type Part no.
A
Non-contact 67 mm – LFV200-XXTGACPV 6036373
G 1 A PN 64
switch

Non-contact
–40 °C ... +150 °C
115 mm
67 mm


LFV200-XXTGACPVL
LFV200-XXTGBCPV
6037307
6036371
B
G ¾ A PN 64 –40 °C ... +150 °C

C
switch 115 mm – LFV200-XXTGBCPVL 6042248

Non-contact 67 mm – LFV200-XXTNACPV 6036374


1” NPT PN 64 –40 °C ... +150 °C
switch 115 mm – LFV200-XXTNACPVL 6037308

¾” NPT PN 64
Non-contact
switch
–40 °C ... +150 °C 67 mm – LFV200-XXTNBCPV 6036372
D


Enclosure rating: IP67
Process pressure: –1 bar ... +64 bar E
• Housing material: Stainless steel 1.4404, PEI
• Electrical connection: M12 round connector x 1, 4-pin
Process connection Output signal Process temperature Probe length WHG Type Part no.
F
approval
Triclamp 1’’ (PN 16, 316L, Transistor output
–40 °C ... +150 °C 67 mm l LFV200-XAHCLTPM 6036538
Ra<0.8μm) PNP
Triclamp 2’’ (PN 16, 316L, Transistor output
–40 °C ... +150 °C 67 mm l LFV200-XAHCNTPM 6036539

H
Ra < 0.8μm) PNP
Conical coupling DN 25 acc.
to DIN 11851 with Transistor output
–40 °C ... +150 °C 67 mm l LFV200-XAHRLTPM 6036540
Union nut (PN 40, 316L, Ra PNP
< 0.8µm)
Conical coupling DN 40 acc.
To DIN 11851 with union Transistor output
I
–40 °C ... +150 °C 67 mm l LFV200-XAHRMTPM 6036541

J
nut (PN 40, 316L, Ra < PNP
0.8µm)
Conical coupling DN 50 acc.
to DIN 11851 with Transistor output
–40 °C ... +150 °C 67 mm LFV200-XAHRNTPM 6036542

K
l
Union nut (PN 40, 316L, Ra PNP
< 0.8µm)
Transistor output 67 mm l LFV200-XASGATPM 6036361
G 1 A PN 64 –40 °C ... +100 °C

L
PNP 115 mm l LFV200-XASGATPML 6037297

Transistor output 67 mm l LFV200-XASGBTPM 6036359


G ¾ A PN 64 –40 °C ... +100 °C
PNP 115 mm l LFV200-XASGBTPML 6037458

G ½ A PN 64
Transistor output
PNP
Transistor output
–40 °C ... +100 °C 67 mm l LFV200-XASGHTPM 6050754
M
G 1½ A PN 64 –40 °C ... +100 °C 115 mm l LFV200-XASGHTPML 6039226

N
PNP
Transistor output 67 mm l LFV200-XASNATPM 6036362
1” NPT PN 64 –40 °C ... +100 °C
PNP 115 mm l LFV200-XASNATPML 6037298

¾” NPT PN 64
Transistor output
PNP
Transistor output
–40 °C ... +100 °C 67 mm l LFV200-XASNBTPM 6036360
O
½’’ NPT PN 64 –40 °C ... +100 °C 67 mm l LFV200-XASNHTPM 6053354
PNP

G 1 A PN 64
Transistor output
PNP
–40 °C ... +150 °C
67 mm
115 mm
l
l
LFV200-XATGATPM
LFV200-XATGATPML
6036365
6037299
P
Q
Transistor output 67 mm l LFV200-XATGBTPM 6036363
G ¾ A PN 64 –40 °C ... +150 °C
PNP 115 mm l LFV200-XATGBTPML 6037460
Transistor output
G ½ A PN 64 –40 °C ... +150 °C 67 mm l LFV200-XATGHTPM 6054808

R
PNP
Transistor output 67 mm l LFV200-XATNATPM 6036366
1” NPT PN 64 –40 °C ... +150 °C
PNP 115 mm l LFV200-XATNATPML 6037300

¾” NPT PN 64
Transistor output
PNP
–40 °C ... +150 °C 67 mm l LFV200-XATNBTPM 6036364
S
8012597/2019-02-08
Subject to change without notice
F l u i d s e n s o r s | SI C K 11
T
LFV200 Level sensors

A Process connection Output signal Process temperature Probe length WHG


approval
Type Part no.

Transistor output

B
–40 °C ... +150 °C 67 mm – LFV200-XXHCLIPM 6066388
PNP with IO-Link
Triclamp 1’’ (PN 16, 316L,
Ra<0.8μm) Transistor output LFV200-XXHCLTPM 6036533
–40 °C ... +150 °C 67 mm –
PNP LFV200-XXHCLTPMG 6049762

C Tri-Clamp 2’’ (316L, Ra


< 0.8 μm)
Triclamp 2’’ (PN 16, 316L,
Transistor output
PNP with IO-Link
Transistor output
–40 °C ... +150 °C 67 mm – LFV200-XXHCNIPM 6066395

–40 °C ... +150 °C 67 mm – LFV200-XXHCNTPM 6036534

D
Ra < 0.8μm) PNP
G ¾, DIN 3852-A PN 64 / Transistor output
–40 °C ... +150 °C 67 mm – LFV200-XXHGPIPM 6066384
316L, Ra < 0,8 µm PNP with IO-Link
Transistor output

E
¾” NPT PN 64 –40 °C ... +150 °C 67 mm – LFV200-XXHNPIPM 6066394
PNP with IO-Link
Conical coupling DN 25 acc.
to DIN 11851 with Transistor output
–40 °C ... +150 °C 67 mm – LFV200-XXHRLTPM 6036535

F
Union nut (PN 40, 316L, Ra PNP
< 0.8µm)
Conical coupling DN 40 acc.
To DIN 11851 with union Transistor output
–40 °C ... +150 °C 67 mm – LFV200-XXHRMTPM 6036536
nut (PN 40, 316L, Ra < PNP
0.8µm)
Conical coupling DN 50 acc.
to DIN 11851 with Transistor output

H
–40 °C ... +150 °C 67 mm – LFV200-XXHRNTPM 6036537
Union nut (PN 40, 316L, Ra PNP
< 0.8µm)
Transistor output
–40 °C ... +100 °C 67 mm – LFV200-XXSGAIPM 6066386

I
PNP with IO-Link
G 1 A PN 64 67 mm – LFV200-XXSGATPM 6036353
Transistor output
–40 °C ... +100 °C
PNP 115 mm – LFV200-XXSGATPML 6037293

J G ¾ A PN 64
Transistor output
PNP with IO-Link
–40 °C ... +100 °C 67 mm

67 mm


LFV200-XXSGBIPM

LFV200-XXSGBTPM
6066347

6036351
Transistor output
–40 °C ... +100 °C

K
PNP 115 mm – LFV200-XXSGBTPML 6037457
Transistor output
–40 °C ... +100 °C 67 mm – LFV200-XXSGHIPM 6048862
PNP with IO-Link
G ½ A PN 64

L
Transistor output
–40 °C ... +100 °C 67 mm – LFV200-XXSGHTPM 6048704
PNP
Transistor output
–40 °C ... +100 °C 67 mm – LFV200-XXSNAIPM 6066382
PNP with IO-Link

M 1” NPT PN 64
Transistor output
PNP
–40 °C ... +100 °C
67 mm
115 mm


LFV200-XXSNATPM
LFV200-XXSNATPML
6036354
6037294
Transistor output

N ¾” NPT PN 64
PNP with IO-Link
Transistor output
–40 °C ... +100 °C

–40 °C ... +100 °C


67 mm

67 mm


LFV200-XXSNBIPM

LFV200-XXSNBTPM
6066393

6036352
PNP

O ½’’ NPT PN 64
Transistor output
PNP with IO-Link
Transistor output
–40 °C ... +100 °C 67 mm – LFV200-XXSNHIPM 6048863

–40 °C ... +100 °C 67 mm – LFV200-XXSNHTPM 6048864


PNP

P G 1 A PN 64
Transistor output
PNP with IO-Link
–40 °C ... +150 °C 67 mm – LFV200-XXTGAIPM 6066390

Transistor output 67 mm – LFV200-XXTGATPM 6036357

Q
–40 °C ... +150 °C
PNP 115 mm – LFV200-XXTGATPML 6037295
Transistor output
–40 °C ... +150 °C 67 mm – LFV200-XXTGBIPM 6066385
PNP with IO-Link

R G ¾ A PN 64
Transistor output
PNP
–40 °C ... +150 °C
67 mm
115 mm


LFV200-XXTGBTPM
LFV200-XXTGBTPML
6036355
6037459

S
T 12 F l u i d s e n s o r s | SI C K 8012597/2019-02-08
Subject to change without notice
Level sensors LFV200

Process connection Output signal Process temperature Probe length WHG


approval
Type Part no.
A
Transistor output

B
–40 °C ... +150 °C 67 mm – LFV200-XXTGHIPM 6066392
PNP with IO-Link
G ½ A PN 64
Transistor output
–40 °C ... +150 °C 67 mm – LFV200-XXTGHTPM 6052475
PNP

C
Transistor output
–40 °C ... +150 °C 67 mm – LFV200-XXTNAIPM 6066387
PNP with IO-Link
1” NPT PN 64 67 mm – LFV200-XXTNATPM 6036358
Transistor output
–40 °C ... +150 °C
PNP

D
115 mm – LFV200-XXTNATPML 6037296
Transistor output
–40 °C ... +150 °C 67 mm – LFV200-XXTNBIPM 6066391
PNP with IO-Link
¾” NPT PN 64
Transistor output

E
–40 °C ... +150 °C 67 mm – LFV200-XXTNBTPM 6036356
PNP
Transistor output
½’’ NPT PN 64 –40 °C ... +150 °C 67 mm – LFV200-XXTNHIPM 6066389
PNP with IO-Link

LFV230
F
• Enclosure rating: IP65
• Output signal: Non-contact switch
• Process temperature: –40 °C ... +100 °C
• Process pressure: –1 bar ... +64 bar


Housing material: Stainless steel 1.4404, PEI
Electrical connection: Valve plug DIN 43650 H
I
Process connection Probe length Type Part no.
80 mm LFV230-XXSGBCPV0080 6043182
100 mm LFV230-XXSGBCPV0100 6044782
120 mm
190 mm
LFV230-XXSGBCPV0120
LFV230-XXSGBCPV0190
6043602
6044688
J
K
200 mm LFV230-XXSGBCPV0200 6048454
G ¾ A PN 64
270 mm LFV230-XXSGBCPV0270 6049420
300 mm LFV230-XXSGBCPV0300 6044007
400 mm
500 mm
LFV230-XXSGBCPV0400
LFV230-XXSGBCPV0500
6042265
6044008
L
600 mm LFV230-XXSGBCPV0600 6057016
1” NPT PN 64 128 mm LFV230-XXSNACPV0128 6042997
M



Enclosure rating: IP67
Process pressure: –1 bar ... +64 bar
Housing material: Stainless steel 1.4404, PEI
N
O
• Electrical connection: M12 round connector x 1, 4-pin
Process connection Output signal Process temperature Probe length Type Part no.
100 mm LFV230-XXHCLIPM0100 6066416

Triclamp 1’’ (PN 16, Transistor output PNP


–40 °C ... +150 °C
150 mm
200 mm
LFV230-XXHCLIPM0150
LFV230-XXHCLIPM0200
6066417
6066418
P
316L, Ra<0.8μm) with IO-Link
500 mm
750 mm
LFV230-XXHCLIPM0500
LFV230-XXHCLIPM0750
6066419
6066420 Q
R
S
8012597/2019-02-08
Subject to change without notice
F l u i d s e n s o r s | SI C K 13
T
LFV200 Level sensors

A Process connection Output signal Process temperature Probe length


100 mm
Type
LFV230-XXHCNIPM0100
Part no.
6066421

B
150 mm LFV230-XXHCNIPM0150 6066422
Triclamp 2’’ (PN 16, Transistor output PNP
–40 °C ... +150 °C 200 mm LFV230-XXHCNIPM0200 6066423
316L, Ra < 0.8μm) with IO-Link
500 mm LFV230-XXHCNIPM0500 6066424

C 750 mm
100 mm
LFV230-XXHCNIPM0750
LFV230-XXSGAIPM0100
6066425
6066406

D
150 mm LFV230-XXSGAIPM0150 6066407
Transistor output PNP
G 1 A PN 64 –40 °C ... +100 °C 200 mm LFV230-XXSGAIPM0200 6066408
with IO-Link
500 mm LFV230-XXSGAIPM0500 6066409

E 750 mm
100 mm
LFV230-XXSGAIPM0750
LFV230-XXSGBIPM0100
6066410
6066411
150 mm LFV230-XXSGBIPM0150 6066412

F Transistor output PNP


with IO-Link
–40 °C ... +100 °C 200 mm
500 mm
LFV230-XXSGBIPM0200
LFV230-XXSGBIPM0500
6066413
6066414
G ¾ A PN 64
750 mm LFV230-XXSGBIPM0750 6066415
80 mm LFV230-XXSGBTPM0080 6042999
Transistor output PNP –40 °C ... +100 °C 85 mm LFV230-XXSGBTPM0085 6053321

H 90 mm
100 mm
LFV230-XXSGBTPM0090
LFV230-XXSGBTPM0100
6049513
6048000

I
110 mm LFV230-XXSGBTPM0110 6052799
Transistor output PNP –40 °C ... +100 °C
120 mm LFV230-XXSGBTPM0120 6049427
130 mm LFV230-XXSGBTPM0130 6049514

J 150 mm
160 mm
LFV230-XXSGBTPM0150
LFV230-XXSGBTPM0160
6043000
6051726
175 mm LFV230-XXSGBTPM0175 6055023

K –40 °C ... +100 °C


200 mm
230 mm
LFV230-XXSGBTPM0200
LFV230-XXSGBTPM0230
6041848
6065706

L 250 mm
300 mm
LFV230-XXSGBTPM0250
LFV230-XXSGBTPM0300
6043515
6041850
310 mm LFV230-XXSGBTPM0310 6052516

M G ¾ A PN 64 325 mm
350 mm
LFV230-XXSGBTPM0325
LFV230-XXSGBTPM0350
6053782
6049151

N
Transistor output PNP 400 mm LFV230-XXSGBTPM0400 6041852
450 mm LFV230-XXSGBTPM0450 6057102
500 mm LFV230-XXSGBTPM0500 6041682

O –40 °C ... +100 °C


600 mm
650 mm
LFV230-XXSGBTPM0600
LFV230-XXSGBTPM0650
6041855
6052934
700 mm LFV230-XXSGBTPM0700 6041857

P 800 mm
900 mm
LFV230-XXSGBTPM0800
LFV230-XXSGBTPM0900
6041860
6041862

Q 1,000 mm
1,100 mm
LFV230-XXSGBTPM1000
LFV230-XXSGBTPM1100
6041669
6041864
1,200 mm LFV230-XXSGBTPM1200 6041865

R
S
T 14 F l u i d s e n s o r s | SI C K 8012597/2019-02-08
Subject to change without notice
Level sensors LFV200

Process connection Output signal Process temperature Probe length


200 mm
Type
LFV230-XXSNBTPM0200
Part no.
6041847
A
B
300 mm LFV230-XXSNBTPM0300 6041849
Transistor output PNP –40 °C ... +100 °C
340 mm LFV230-XXSNBTPM0340 6052264
400 mm LFV230-XXSNBTPM0400 6041851
500 mm
600 mm
LFV230-XXSNBTPM0500
LFV230-XXSNBTPM0600
6041853
6041854
C
¾” NPT PN 64

D
700 mm LFV230-XXSNBTPM0700 6041856
800 mm LFV230-XXSNBTPM0800 6041858
Transistor output PNP –40 °C ... +100 °C
900 mm LFV230-XXSNBTPM0900 6041859
1,000 mm
1,100 mm
LFV230-XXSNBTPM1000
LFV230-XXSNBTPM1100
6041861
6041863 E
1,200 mm LFV230-XXSNBTPM1200 6041866
100 mm
130 mm
LFV230-XXTGBTPM0100
LFV230-XXTGBTPM0130
6041902
6053662
F
150 mm LFV230-XXTGBTPM0150 6052476
200 mm LFV230-XXTGBTPM0200 6041903
250 mm LFV230-XXTGBTPM0250 6054040
300 mm
350 mm
LFV230-XXTGBTPM0300
LFV230-XXTGBTPM0350
6041905
6052875
H
I
400 mm LFV230-XXTGBTPM0400 6041907
G ¾ A PN 64 Transistor output PNP –40 °C ... +150 °C 450 mm LFV230-XXTGBTPM0450 6059425
500 mm LFV230-XXTGBTPM0500 6041909
600 mm
700 mm
LFV230-XXTGBTPM0600
LFV230-XXTGBTPM0700
6041911
6041913
J
800 mm LFV230-XXTGBTPM0800 6041915
900 mm
1,000 mm
LFV230-XXTGBTPM0900
LFV230-XXTGBTPM1000
6041916
6041673
K
1,100 mm
1,200 mm
LFV230-XXTGBTPM1100
LFV230-XXTGBTPM1200
6041919
6041921 L
M
N
O
P
Q
R
S
8012597/2019-02-08
Subject to change without notice
F l u i d s e n s o r s | SI C K 15
T
LFV200 Level sensors

A Dimensional drawings (Dimensions in mm (inch))


Housing (standard tempera- G ¾ A, ¾” NPT G 1 A, 1” NPT G ½ A, ½” NPT
ture range –40 °C ... +100
B
32 32

(0.61)
32

(0.57)

15.5
14.5
°C), DIN 43650 incl. plug (1.26) (1.26) (1.26)

(0.67)
17
angled, IP65

C
36
(1.42)

(2.52)

(0.75)

(2.64)
19
64

(0.79)
D

67

(0.67)
(2.44)
20
(1.5)

17
62
(0.39)

38

(1.5)
10
(3.03)

38

(1.5)
77

38
31.7
( 1.25)

E (0.43)
11 17 17

(0.43)

(0.43)
32 17

11

11
( 0.67) ( 0.67)
(1.26) ( 0.67)

F Housing (enhanced tempera-


ture range –40 °C ... +150
Tri-Clamp 1”, 2” Tri-Clamp 1”, 2” DIN 11851 DN 25, DN 40,
DN 50; DIN 43650 incl. plug
36
°C), DIN 43650 incl. plug (1.42) angled, IP65
angled, IP65 36
(1.42)
36

H
(1.42)
51

(0.39)
(2)

(1.5)

10
38

(0.39)
10
(5.35)
136

I
(0.39)

31.7
(0.43)
10

11

21.3 ( 1.25)

(5.67)
(4.25)

( 0.84)

144
31.7
108

31.7
( 1.25) (1.25)

J 32
(1.26)
51
(2)

(1.5)
38

K 51
(2)

(1.5)
38
(0.43)
11

21.3

L
( 0.84)

(0.43)
11
21.3
( 0.84)

M DIN 11851 DN 25, DN 40,


DN 50
Housing (standard tempera-
ture range –40 °C ... +100
Housing (enhanced tempera-
ture range –40 °C ... 150 °C)
G ¾ A, ¾” NPT
32
(0.57)
14.5

°C), M12 x 1, IP67 M12x1 (1.26)

N M12x1
(0.39)

31.7
(3.15...236.22)

O
10
(2.03)

(3.23)
51.5

31.7 ( 1.25)
(0.39)

80...6000
82

(0.75)
10

( 1.25)
19
51
(2)

32
(1.5)
38

32 (1.26)

P
(1.26)
(1.5)
38
(0.43)

21.3
11

( 0.84) 21.3
(0.43)

Q
11

( 0.84)

R
S
T 16 F l u i d s e n s o r s | SI C K 8012597/2019-02-08
Subject to change without notice
Level sensors LFV200

G 1 A, 1” NPT
32
DIN 11851 DN 25, DN 40,
DN 50, M12 x 1, IP67
Tri-Clamp 1”, 2”
M12 x1
A
(0.61)
15.5

(1.26) M12x1

(0.39)
(0.39)

10
10
C
(3.15...236.22)

(4.33)
(0.79) 31.7

110
31.7
80...6000

( 1.25)
20

(4.65)
( 1.25)

118
D
(1.5)

(3.15...236.22)
38

80...6000

(0.43)
E

11
(3.15...236.22)
(0.43)
11

21.3

(1.5)
80...6000

38
( 0.84)

F
21.3
(1.5)
38

( 0.84)
(0.43)
11

21.3
( 0.84)

Recommended accessories
Mounting systems
H
Flanges
Weld-in flange
I
Brief description

Welded flange/welded connector, DIN11851-1, DN25 / PN40, Stainless steel 1.4404


Type
BEF-FL-851D25-
Part no.

5321527
J
LFV2

Welded flange/welded connector DIN11851-1, DN40 / PN40, Stainless steel 1.4404


BEF-FL-851D40-
LFV2
BEF-FL-851D50-
5321459
K
Welded flange/welded connector DIN11851-1, DN50 / PN25, Stainless steel 1.4404 5321528

L
LFV2

BEF-FL-GEWG10-
Welded flange/welded connector, process connection G 1, Stainless steel 1.4404 4054605
LFV2

Welded flange/welded connector, G 3/4 process connection, Stainless steel 1.4404


BEF-FL-GEWG34-
LFV2
4054604 M
Welded flange/welded connector, process connection Tri-Clamp 1”, Stainless steel
1.4404
Welded flange/welded connector, process connection Tri-Clamp 2”, Stainless steel
BEF-FL-TCLI10-LFV2 5321678
N
BEF-FL-TCLI20-LFV2 5321679

O
1.4404

Connection systems

P
Modules and gateways
Fieldbus modules

Q
Brief description Type Part no.
Number of IO-Link ports: 4; Communication mode: COM1/COM2; IO-Link version:
IO-Link V1.0; Switching input: PNP; Supply voltage Vs, IO-Link ports: DC 24 V; Current

R
loading: 800 mA; Data transmission rate: Max. 12 MBaud, Autobaud; Address space
occupation: 1 bis 126; Connection type: Connector M12; Connection type, IO-Link IOLSHPB-P3104R01 6039728
ports: Connector M12, 5-pin; Suppyl voltage Vs, module: DC 18 ... 30 V; Power con-
sumption: Typ. 75 mA / max. 100 mA (at UL with DC 24 V), Typ. 25 mA + sensor current

S
/ max. 80

8012597/2019-02-08
Subject to change without notice
F l u i d s e n s o r s | SI C K 17
T
LFV200 Level sensors

A IOLSHPB-P3104R01
40 (1.6) 70 (2.76)
31

B (1.22)

1
C
0
2
x10 12 4
10 6
8

2 4
0
2
x1 4
6
98

6
D

178 (7.01)
168 (6.61)
E
5

F 3

49,3 (1.94)

1 Bus IN

H 2 Bus OUT
3 Power supply IN
4 Power supply OUT
5 Port 1...4

I 6 Bus adress rotary switch

J
K
L
M
N
O
P
Q
R
S
T 18 F l u i d s e n s o r s | SI C K 8012597/2019-02-08
Subject to change without notice
SERVICES

REGISTER AT WWW.SICK.COM TO TAKE ADVANTAGE A


OF OUR FOLLOWING SERVICES FOR YOU
B
m Access information on net prices and individual discounts.
m
m
Easily order online and track your delivery.
Check your history of all your orders and quotes.
C
m
m
Create, save, and share as many wish lists as you want.
Use the direct order to quickly order a big amount of
D
products.
m Check the status of your orders and quotes and get infor-
mation on status changes by e-mail.
E
m
m
Save time by using past orders.
Easily export orders and quotes, suited to your systems. F

H
I
J
SERVICES FOR MACHINES AND PLANTS: SICK LifeTime Services
Our comprehensive and versatile LifeTime Services are the perfect addition to the comprehensive range of products from
SICK. The services range from product-independent consulting to traditional product services.
K
L
Consulting and design
Safe and professional
M
Product and system support
Reliable, fast, and on-site N
Verification and optimization O
Safe and regularly inspected

P
Upgrade and retrofits
Easy, safe, and economical
Q
Training and education
Practical, focused, and professional R
S
8012597/2019-02-08
Subject to change without notice
F l u i d s e n s o r s | SI C K
T
SICK AT A GLANCE
8012597/2019-02-08 ∙ 9MS ∙ Pre USmod en48

SICK is a leading manufacturer of intelligent sensors and sensor solutions for industrial applications. With
more than 8,800 employees and over 50 subsidiaries and equity investments as well as numerous agencies
worldwide, SICK is always close to its customers. A unique range of products and services creates the
perfect basis for controlling processes securely and efficiently, protecting individuals from accidents, and
preventing damage to the environment.

SICK has extensive experience in various industries and understands their processes and requirements.
With intelligent sensors, SICK delivers exactly what the customers need. In application centers in Europe,
Asia, and North America, system solutions are tested and optimized in accordance with customer specifica-
tions. All this makes SICK a reliable supplier and development partner.

Comprehensive services round out the offering: SICK LifeTime Services provide support throughout the
machine life cycle and ensure safety and productivity.

That is “Sensor Intelligence.”

Worldwide presence:

Australia, Austria, Belgium, Brazil, Canada, Chile, China, Czech Republic, Denmark, Finland, France,
Germany, Great Britain, Hungary, Hong Kong, India, Israel, Italy, Japan, Malaysia, Mexico, Netherlands,
New Zealand, Norway, Poland, Romania, Russia, Singapore, Slovakia, Slovenia, South Africa, South Korea,
Spain, Sweden, Switzerland, Taiwan, Thailand, Turkey, United Arab Emirates, USA, Vietnam.

Detailed addresses and further locations - www.sick.com

SICK AG | Waldkirch | Germany | www.sick.com


P R O D U C T I N FO R M AT I O N
UP56 Pure
PURE RELIABILITY

Level sensors
UP56 Pure Level sensors

A
B PURE RELIABILITY
C Product description

D The non-contact ultrasonic level sensors


from the UP56 Pure product family are
a range of products specialized for wet
ties, thus facilitating the use of dosing
applications. In systems where the
installation is extremely cramped, the

E chemical processes in the electronic


and solar industry. Due to their PTFE-
protected transducer they are very
UP56 Pure Mini is the perfect solution
thanks to its very compact design. The
use in containers with a lot of built-in

F
hardwearing and durable and are de- components is easily resolved by means
signed to be used in highly concentrated of an immersion pipe. The measurement
acids and alkalines. The UP56 Pure is range, output, and filters of the UP56
easy and fast to integrate thanks to the product family is easy and convenient to
industry-specific GF process connec- adjust with the PC-based programming
tion. A high level of accuracy can also be tool Connect+.

H
achieved with fluctuating liquid densi-

At a glance

I • Ultrasonic level sensor with very high


chemical resistance
• Non-contact measurement in immer-
• Pressure resistant up to 6 bar, tem-
perature resistant up to 85°C
• Different sizes available

J sion pipe of up to 1,500 mm


• PTFE-coated membrane and GF D40
process connection made of PTFE
• Analog output selectable between
4 mA to 20 mA and 0 V to 10 V
• Switching output for monitoring the

K maximum and minimum limit

Your benefits

L • Non-contact and non-wearing mea-


surement reduces maintenance and
• High accuracy measurements, even
in liquids with density fluctuations
servicing cost • Faultless operation with very limited

M • Sensor replacement possible even


with chemicals present, thus saving
installation space in the tote
• Switching output and analog output
time and increasing availability in a single sensor reduces time and

N • Universally applicable with acidic and


alkaline processes
money spent on wiring
• Simple and time-saving configuration
• Flexible measurement system for dif- with Connect+

O ferent container sizes provides cost


reductions

P Additional information
Detailed technical data������������������������3

Q Ordering information����������������������������4
Type code����������������������������������������������4

R
Dimensional drawings��������������������������5
Electrical connection����������������������������5
Connection diagram����������������������������5 -- www.sick.com/UP56_Pure

S Accessories������������������������������������������5 For more information, simply enter the link or scan the QR code and get direct access to techni-
cal data, CAD design models, operating instructions, software, application examples, and much
more.

T 2 F l u i d s e n s o r s | SI C K 8016461/2018-12-03
Subject to change without notice
Level sensors UP56 Pure

Detailed technical data


Features
A
Medium Fluids
UP56-211 UP56-212 UP56-216
B
C
Measurement Switch, continuous
Measuring range in tank 30 mm ... 250 mm 85 mm ... 350 mm 65 mm ... 700 mm
Measuring range immersion tube 30 mm ... 500 mm 85 mm ... 1,500 mm 65 mm ... 1,500 mm
Process pressure
Process temperature
0 bar ... 6 bar, gauge pressure for UP56 Pure mini (depending on type)
–25 °C ... +85 °C D
Performance
UP56-211 UP56-212 UP56-216
E
Accuracy of sensor element
F
≤ 1 % 1)
Repeatability ± 0.15 % 1)
Resolution ≤ 0.025 mm ≤ 0.18 mm
Response time ≤ 84 ms 2)

Display Without design specifics

H
1)
From the full scale value.
2)
Recovery time 32 ms ... 180 ms according to EMC EN 60947-5-7.

Mechanics
Process connection
Housing material
GF connection D40
PTFE, PP
I
Housing design
Weight
Standard / Mini (depending on type)
210 g J
145 g UP56 Pure Mini

Electronics
(depending on type)
K
Supply voltage
UP56-211
9 V DC ... 30 V DC 1)
UP56-212 UP56-216
L
M
Residual ripple ± 10 %
Power consumption ≤ 80 mA 2)
Protection class III
Electrical connection
Output signal
Round connector M12 x 1, 5-pin
1 x PNP + 4 mA ... 20 mA / 0 V ... 10 V 3) 4)
N
4 mA ... 20 mA 3) 4)

Hysteresis
(depending on type)
3 mm
3 mm 5)
5 mm
5 mm 5)
O
Signal voltage HIGH
Output current
Uv –3 V
200 mA P
Time delay before availability ≤ 300 ms
Enclosure rating
Ultrasonic frequency
IP 67
320 kHz 200 kHz
Q
R
1)
 Reverse-polarity protected.
2)
At 24 V DC without output load.
3)
Short-circuit protected, reversible.
4)
Automatic switching between voltage and current outputs dependet on load 4 mA ... 20 mA: RL ≤ 100 / at 9 V ≤ UB ≤20 V; RL ≤ 500/ at UB ≥ 20 V; 0 V ... 10 V: RL

5)
≥ 100 k / at UB ≥ 15 V, short-circuit protected.
Free adjustable in 1 mm steps via Connect+ Adapter (CPA) S
8016461/2018-12-03
Subject to change without notice
F l u i d s e n s o r s | SI C K 3
T
UP56 Pure Level sensors

A Ultrasonic transducer
UP56-211
PTFE coating, FFKM
UP56-212 UP56-216

B
1)
 Reverse-polarity protected.
2)
At 24 V DC without output load.
3)
Short-circuit protected, reversible.
4)
Automatic switching between voltage and current outputs dependet on load 4 mA ... 20 mA: RL ≤ 100 / at 9 V ≤ UB ≤20 V; RL ≤ 500/ at UB ≥ 20 V; 0 V ... 10 V: RL

C 5)
≥ 100 k / at UB ≥ 15 V, short-circuit protected.
Free adjustable in 1 mm steps via Connect+ Adapter (CPA)

Ambient data
D Ambient operating temperature –25 °C ... +70 °C 1)
Ambient storage temperature –40 °C ... +85 °C

E 1)
Temperature compensation at –25 °C ... +50 °C, can be switched off.

F Ordering information
• Enclosure rating: IP 67
• Process connection: GF connection D40
• Process temperature: –25 °C ... +85 °C
• Housing material: PTFE, PP
• Electrical connection: round connector M12 x 1, 5-pin

H Output signal

1 x PNP + 4 mA ...
Process pressure Measuring range in
tank
Measuring range im-
mersion tube
Type Part no.

0 bar ... 6 bar 30 mm ... 250 mm 30 mm ... 500 mm UP56-211148 6048942

I
20 mA / 0 V ... 10 V
4 mA ... 20 mA 0 bar ... 2 bar 30 mm ... 250 mm 30 mm ... 500 mm UP56-211156 6050441
1 x PNP + 4 mA ...
0 bar ... 6 bar 85 mm ... 350 mm 85 mm ... 1,500 mm UP56-212148 6048943

J
20 mA / 0 V ... 10 V
4 mA ... 20 mA 0 bar ... 2 bar 85 mm ... 350 mm 85 mm ... 1,500 mm UP56-212156 6049945
1 x PNP + 4 mA ...
0 bar ... 6 bar 65 mm ... 700 mm 65 mm ... 1,500 mm UP56-216148 6049450
20 mA / 0 V ... 10 V

K 4 mA ... 20 mA 0 bar ... 2 bar 65 mm ... 700 mm 65 mm ... 1,500 mm UP56-216156 6049617

L Type code

M
Insertion length
1 30 mm … 250 mm
2 85 mm … 350 mm
6 65 mm … 700 mm

N
Connection technology
1 Round connector M12 x 1, 5-pin
Process connection/Housing
4 GF thread D40, PTFE / plastic PP w/o display
5 GF thread D40, PTFE / plastic PP w/o display / short housing (mini)

O Output signal
6 Analog, current output
8 Analog, current and voltage output + 1 PNP-transistor output

P UP 56 - 2 1 1

Q
Not all variations of the type code can be combined!

R
S
T 4 F l u i d s e n s o r s | SI C K 8016461/2018-12-03
Subject to change without notice
Level sensors UP56 Pure

Dimensional drawings (Dimensions in mm (inch))


UP56 Pure UP56 Pure Mini
A
B

1.97)
50
1.18)
30

2.22)

1.18)

2.22)
(

56.4
M12x1
50

30
(
C

(
2.22)
56.4
M12x1

(
10.5 28.9 6.1
(0.41) (1.14) (0.24)

10.5
(0.41)
28.9
(1.14)
6.1
(0.24)
56.1
(2.21) E
116.5
(4.59)
F
Electrical connection Connection diagram
Male connector M12, 5-pin 1 x PNP + 4 mA ... 20 mA / 4 mA ... 20 mA
0 V ... 10 V

H
brn 1
L+
brn 1 4
L+ blk
nc
wht 2 3
QA blu

I
M
blk 4
QPNP wht 2
QA
gra 5
Sync/Com gra 5
Sync/Com
3

J
blu
M

K
Accessories
Connection systems L
Plug connectors and cables
Connecting cables with female connector
M
Brief description Cable length Type Part no.

Head A: female connector, M12, 5-pin,


straight
N
2m DOL-1205-G02M 6008899
Head B: cable
Illustration may Cable: PVC, unshielded
differ
Head A: female connector, M12, 5-pin,
O
P
straight
Head B: cable 2m DOL-1205-G02MC 6025906
Cable: drag chain use, PUR, halogen-free,
unshielded

Head A: female connector, M12, 5-pin,


straight
5m DOL-1205-G05M 6009868
Q
Head B: cable
Illustration may Cable: PVC, unshielded
differ
R
S
8016461/2018-12-03
Subject to change without notice
F l u i d s e n s o r s | SI C K 5
T
UP56 Pure Level sensors

A Brief description
Head A: female connector, M12, 5-pin,
Cable length Type Part no.

straight

B Head B: cable
Cable: drag chain use, PUR, halogen-free,
unshielded
5m DOL-1205-G05MC 6025907

C Head A: female connector, M12, 5-pin,


straight
Head B: cable
10 m DOL-1205-G10M 6010544

D
Illustration may Cable: PVC, unshielded
differ
Head A: female connector, M12, 5-pin,
straight

E
Head B: cable 10 m DOL-1205-G10MC 6025908
Cable: drag chain use, PUR, halogen-free,
unshielded

F Head A: female connector, M12, 5-pin,


angled
Head B: cable
2m DOL-1205-W02M 6008900
Illustration may Cable: PVC, unshielded
differ
Head A: female connector, M12, 5-pin,
angled
Head B: cable 2m DOL-1205-W02MC 6025909

H Cable: drag chain use, PUR, halogen-free,


unshielded
5m DOL-1205-W05M 6009869

I
Head A: female connector, M12, 5-pin,
angled
Head B: cable 10 m DOL-1205-W10M 6010542
Illustration may Cable: PVC, unshielded

J
differ
Head A: female connector, M12, 5-pin,
angled
Head B: cable 10 m DOL-1205-W10MC 6025911

K Cable: drag chain use, PUR, halogen-free,


unshielded

Further accessories
L Programming and configuration tools

M
Brief description Type Part no.

Tool for visualization, configuration and cloning, 3-digit LED display, supply voltage: DV Connect+ adapter
6037782
9 V ... 30 V (CPA)

N
O
P
Q
R
S
T 6 F l u i d s e n s o r s | SI C K 8016461/2018-12-03
Subject to change without notice
SERVICES

REGISTER AT WWW.SICK.COM TO TAKE ADVANTAGE


OF OUR FOLLOWING SERVICES FOR YOU

m Access information on net prices and individual discounts.


m Easily order online and track your delivery.
m Check your history of all your orders and quotes.
m Create, save, and share as many wish lists as you want.
m Use the direct order to quickly order a big amount of
products.
m Check the status of your orders and quotes and get
information on status changes by e-mail.
m Save time by using past orders.
m Easily export orders and quotes, suited to your systems.

SERVICES FOR MACHINES AND PLANTS: SICK LifeTime Services


Our comprehensive and versatile LifeTime Services are the perfect addition to the comprehensive range of products from
SICK. The services range from product-independent consulting to traditional product services.

Consulting and design


Safe and professional

Product and system support


Reliable, fast, and on-site

Verification and optimization


Safe and regularly inspected

Upgrade and retrofits


Easy, safe, and economical

Training and education


Practical, focused, and professional

8016461/2018-12-03 F l u i d s e n s o r s | SI C K 7
Subject to change without notice
SICK AT A GLANCE
8016461/2018-12-03 ∙ 9MS ∙ Pre USmod en48

SICK is a leading manufacturer of intelligent sensors and sensor solutions for industrial applications. With
more than 8,800 employees and over 50 subsidiaries and equity investments as well as numerous agencies
worldwide, SICK is always close to its customers. A unique range of products and services creates the
perfect basis for controlling processes securely and efficiently, protecting individuals from accidents, and
preventing damage to the environment.

SICK has extensive experience in various industries and understands their processes and requirements.
With intelligent sensors, SICK delivers exactly what the customers need. In application centers in Europe,
Asia, and North America, system solutions are tested and optimized in accordance with customer specifica-
tions. All this makes SICK a reliable supplier and development partner.

Comprehensive services round out the offering: SICK LifeTime Services provide support throughout the
machine life cycle and ensure safety and productivity.

That is “Sensor Intelligence.”

Worldwide presence:

Australia, Austria, Belgium, Brazil, Canada, Chile, China, Czech Republic, Denmark, Finland, France,
Germany, Great Britain, Hungary, Hong Kong, India, Israel, Italy, Japan, Malaysia, Mexico, Netherlands,
New Zealand, Norway, Poland, Romania, Russia, Singapore, Slovakia, Slovenia, South Africa, South Korea,
Spain, Sweden, Switzerland, Taiwan, Thailand, Turkey, United Arab Emirates, USA, Vietnam.

Detailed addresses and further locations - www.sick.com

SICK AG | Waldkirch | Germany | www.sick.com

Для заказов : +7(499)707-11-20 Email: i@sp-t.ru 8-800-511-65-88 (Бесплатно по РФ)