Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Version 7.2.

PVsyst - Simulation report


Grid-Connected System

Project: Aditya Haryo


Variant: New simulation variant
No 3D scene defined, no shadings
System power: 7.63 kWp
Aditya Haryo - Indonesia

Author
Project: Aditya Haryo
Variant: New simulation variant

PVsyst V7.2.8
VC0, Simulation date:
06/03/23 13:45
with v7.2.8

Project summary
Geographical Site Situation Project settings
Aditya Haryo Latitude -6.26 °S Albedo 0.20
Indonesia Longitude 106.74 °E
Altitude 22 m
Time zone UTC+7

Meteo data
Aditya Haryo
Meteonorm 8.0 (2010-2014), Sat=100% - Synthetic

System summary
Grid-Connected System No 3D scene defined, no shadings
Simulation for year no 25

PV Field Orientation Near Shadings User's needs


Fixed plane No Shadings Unlimited load (grid)
Tilt/Azimuth 5/0°

System information
PV Array Inverters
Nb. of modules 14 units Nb. of units 1 Unit
Pnom total 7.63 kWp Pnom total 7.00 kWac
Pnom ratio 1.090

Results summary
Produced Energy 10.49 MWh/year Specific production 1375 kWh/kWp/year Perf. Ratio PR 78.39 %

Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Main results 5
Loss diagram 6
Special graphs 7

06/03/23 PVsyst Licensed to Page 2/7


Project: Aditya Haryo
Variant: New simulation variant

PVsyst V7.2.8
VC0, Simulation date:
06/03/23 13:45
with v7.2.8

General parameters
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 5/0° Diffuse Perez, Meteonorm
Circumsolar separate

Horizon Near Shadings User's needs


Free Horizon No Shadings Unlimited load (grid)

PV Array Characteristics
PV module Inverter
Manufacturer JA Solar Manufacturer Growatt New Energy
Model JAM72S30_545_MR Model MIN 7000TL-X
(Custom parameters definition) (Original PVsyst database)
Unit Nom. Power 545 Wp Unit Nom. Power 7.00 kWac
Number of PV modules 14 units Number of inverters 1 unit
Nominal (STC) 7.63 kWp Total power 7.0 kWac
Modules 2 Strings x 7 In series Operating voltage 60-550 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.09
Pmpp 7.07 kWp
U mpp 267 V
I mpp 27 A

Total PV power Total inverter power


Nominal (STC) 8 kWp Total power 7 kWac
Total 14 modules Nb. of inverters 1 Unit
Module area 36.2 m² Pnom ratio 1.09

Array losses
Array Soiling Losses Thermal Loss factor DC wiring losses
Loss Fraction 3.0 % Module temperature according to irradiance Global array res. 141 mΩ
Uc (const) 20.0 W/m²K Loss Fraction 1.3 % at STC
Uv (wind) 0.0 W/m²K/m/s

Module Quality Loss Module mismatch losses Strings Mismatch loss


Loss Fraction 0.0 % Loss Fraction 2.0 % at MPP Loss Fraction 0.1 %

Module average degradation


Year no 25
Loss factor 0.02 %/year
Mismatch due to degradation
Imp RMS dispersion 0.4 %/year
Vmp RMS dispersion 0.4 %/year

IAM loss factor


Incidence effect (IAM): Fresnel smooth glass, n = 1.526

0° 30° 50° 60° 70° 75° 80° 85° 90°


1.000 0.998 0.981 0.948 0.862 0.776 0.636 0.403 0.000

06/03/23 PVsyst Licensed to Page 3/7


Project: Aditya Haryo
Variant: New simulation variant

PVsyst V7.2.8
VC0, Simulation date:
06/03/23 13:45
with v7.2.8

AC wiring losses
Inv. output line up to injection point
Inverter voltage 220 Vac mono
Loss Fraction 0.39 % at STC
Inverter: MIN 7000TL-X
Wire section (1 Inv.) Copper 1 x 2 x 6 mm²
Wires length 4m

06/03/23 PVsyst Licensed to Page 4/7


Project: Aditya Haryo
Variant: New simulation variant

PVsyst V7.2.8
VC0, Simulation date:
06/03/23 13:45
with v7.2.8

Main results
System Production
Produced Energy 10.49 MWh/year Specific production 1375 kWh/kWp/year
Performance Ratio PR 78.39 %

Normalized productions (per installed kWp) Performance Ratio PR

Balances and main results

GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_Grid PR


kWh/m² kWh/m² °C kWh/m² kWh/m² MWh MWh ratio
January 125.1 69.30 25.93 122.1 113.9 0.746 0.723 0.776
February 138.4 76.87 25.89 136.8 128.5 0.841 0.818 0.783
March 143.7 85.28 26.28 143.9 135.1 0.883 0.859 0.783
April 145.2 76.85 26.32 148.0 139.3 0.909 0.884 0.783
May 141.1 70.26 26.79 145.9 137.2 0.896 0.871 0.783
June 138.9 65.74 26.16 144.9 136.6 0.895 0.871 0.788
July 149.4 68.54 26.01 155.3 146.6 0.959 0.934 0.788
August 156.1 82.26 26.35 160.1 151.3 0.988 0.962 0.787
September 157.7 83.51 26.26 159.4 150.2 0.979 0.953 0.784
October 168.7 97.26 26.88 167.5 157.9 1.028 1.001 0.783
November 141.0 91.49 26.23 138.6 129.9 0.853 0.831 0.786
December 134.7 82.61 26.24 131.4 122.8 0.806 0.783 0.781
Year 1739.9 949.98 26.28 1753.7 1649.2 10.783 10.490 0.784

Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings

06/03/23 PVsyst Licensed to Page 5/7


Project: Aditya Haryo
Variant: New simulation variant

PVsyst V7.2.8
VC0, Simulation date:
06/03/23 13:45
with v7.2.8

Loss diagram
1740 kWh/m² Global horizontal irradiation
+0.8% Global incident in coll. plane

-3.05% IAM factor on global

-3.00% Soiling loss factor

1649 kWh/m² * 36 m² coll. Effective irradiation on collectors

efficiency at STC = 21.12% PV conversion

12.60 MWh Array nominal energy (at STC effic.)


-0.56% Module Degradation Loss ( for year #25)
-0.91% PV loss due to irradiance level

-7.60% PV loss due to temperature

0.00% Module quality loss

-5.23% Mismatch loss, modules and strings


(including 3.1% for degradation dispersion

-0.82% Ohmic wiring loss


10.78 MWh Array virtual energy at MPP
-2.49% Inverter Loss during operation (efficiency)
0.00% Inverter Loss over nominal inv. power
0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage
0.00% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
-0.04% Night consumption
10.51 MWh Available Energy at Inverter Output

-0.19% AC ohmic loss


10.49 MWh Energy injected into grid

06/03/23 PVsyst Licensed to Page 6/7


Project: Aditya Haryo
Variant: New simulation variant

PVsyst V7.2.8
VC0, Simulation date:
06/03/23 13:45
with v7.2.8

Special graphs
Daily Input/Output diagram

System Output Power Distribution

06/03/23 PVsyst Licensed to Page 7/7

You might also like