Aditya Haryo Project - Vc0-Report
Aditya Haryo Project - Vc0-Report
Author
Project: Aditya Haryo
Variant: New simulation variant
PVsyst V7.2.8
VC0, Simulation date:
06/03/23 13:45
with v7.2.8
Project summary
Geographical Site Situation Project settings
Aditya Haryo Latitude -6.26 °S Albedo 0.20
Indonesia Longitude 106.74 °E
Altitude 22 m
Time zone UTC+7
Meteo data
Aditya Haryo
Meteonorm 8.0 (2010-2014), Sat=100% - Synthetic
System summary
Grid-Connected System No 3D scene defined, no shadings
Simulation for year no 25
System information
PV Array Inverters
Nb. of modules 14 units Nb. of units 1 Unit
Pnom total 7.63 kWp Pnom total 7.00 kWac
Pnom ratio 1.090
Results summary
Produced Energy 10.49 MWh/year Specific production 1375 kWh/kWp/year Perf. Ratio PR 78.39 %
Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Main results 5
Loss diagram 6
Special graphs 7
PVsyst V7.2.8
VC0, Simulation date:
06/03/23 13:45
with v7.2.8
General parameters
Grid-Connected System No 3D scene defined, no shadings
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 5/0° Diffuse Perez, Meteonorm
Circumsolar separate
PV Array Characteristics
PV module Inverter
Manufacturer JA Solar Manufacturer Growatt New Energy
Model JAM72S30_545_MR Model MIN 7000TL-X
(Custom parameters definition) (Original PVsyst database)
Unit Nom. Power 545 Wp Unit Nom. Power 7.00 kWac
Number of PV modules 14 units Number of inverters 1 unit
Nominal (STC) 7.63 kWp Total power 7.0 kWac
Modules 2 Strings x 7 In series Operating voltage 60-550 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.09
Pmpp 7.07 kWp
U mpp 267 V
I mpp 27 A
Array losses
Array Soiling Losses Thermal Loss factor DC wiring losses
Loss Fraction 3.0 % Module temperature according to irradiance Global array res. 141 mΩ
Uc (const) 20.0 W/m²K Loss Fraction 1.3 % at STC
Uv (wind) 0.0 W/m²K/m/s
PVsyst V7.2.8
VC0, Simulation date:
06/03/23 13:45
with v7.2.8
AC wiring losses
Inv. output line up to injection point
Inverter voltage 220 Vac mono
Loss Fraction 0.39 % at STC
Inverter: MIN 7000TL-X
Wire section (1 Inv.) Copper 1 x 2 x 6 mm²
Wires length 4m
PVsyst V7.2.8
VC0, Simulation date:
06/03/23 13:45
with v7.2.8
Main results
System Production
Produced Energy 10.49 MWh/year Specific production 1375 kWh/kWp/year
Performance Ratio PR 78.39 %
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings
PVsyst V7.2.8
VC0, Simulation date:
06/03/23 13:45
with v7.2.8
Loss diagram
1740 kWh/m² Global horizontal irradiation
+0.8% Global incident in coll. plane
PVsyst V7.2.8
VC0, Simulation date:
06/03/23 13:45
with v7.2.8
Special graphs
Daily Input/Output diagram