Certificate no: BGN 1500362

Page 1 of 2

Project: ASTILLEROS BALENCIAGA S.A


HULL NO. 407

Client: HALVORSEN POWER SYSTEM AS Office: Bergen

Client’s Order Number: 11646 Date: 07 June 2016

Order Status: Complete

Inspection Dates
First: 14 December 2015 Final: 14 December 2015

This certificate is issued to HALVORSEN POWER SYSTEM AS,Hollundsdalen , Norway, to certify that the components described herein
comply with the requirements of the Rules and Regulations for the Classification of Ships in connection with the intended service. The
undersigned surveyor to Lloyd`s Register EMEA, Bergen, Norway, did at their request attend at their works on
14 December 2015, for the purpose of examining and testing:

One (1) – Power Management System


Type SMART CHIEF III PMS

Made under their works order no. 11646, ordered by, ASTILLEROS BALENCIAGA S.A
and intended for their yard No. 407

Design Appraisal has been carried out by Lloyd’s Register EMEA, Copenhagen, their ref.
C/I111994/1501412/VMB, dated 14. January 2016.
The major hardware units are type approved.

The equipment was visually examined , and material and workmanship found satisfactory. Simulated
function test , according to manufacturer’s FAT procedure 11646.D005 were carried out , and all tested
functions were found to operate satisfactorily.

The test report was signed and stamped by witnessing Surveyor.

Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as
'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or
advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or
advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

Form 1123 (2015.08)


Certificate no: BGN 1500362
Page 2 of 2

Software version used under test:


Controller:
PMS software rev.: 1.0
Powerlink software rev.: 2.2
Configuration files version : 1.0

HMI:
Stinger software version : 1.2.41.0
Spider software version : 1.1.79.1 Birger Strand
Watchdog software version : 2.7.0.1 07 June 2016

Smart PRO project version : 1.0


Bergen Office Office
Senior Surveyor

Lloyd's Register EMEA


LR032.2013.12
Note: Final approval pending satisfactory testing/
Commissioning on board, to the attending Lloyd's Register Group
surveyor’s satisfaction.

B. Strand
Senior Surveyor to Lloyd's Register EMEA

a member of the Lloyd's Register group.