Conforms to 91/155/EEC - 2001/58/EC - United Kingdom (UK)

SAFETY DATA SHEET


AMEROID OSC One Step Cleaner
1. Identification of the substance/preparation and of the company/undertaking
Product name : AMEROID OSC One Step Cleaner
Material Uses : Industrial applications: Cleaning agent for machinery and equipment. Cleaner
for removal of light oil, scale, oxides (rust) and exhaust carbon from metal
surfaces.

Manufacturer / Supplier :
Drew Marine Drew Marine
Ashland Specialty Chemical Company Ashland Specialty Chemical Company
Malledijk 20 One Drew Plaza
3208 LA Spijkenisse Boonton, NJ 07005
Netherlands United States
Tel. No.: Tel. No.:
+31 181 457 070 +1 (973) 263 7600
Fax: Fax:
+31 181 625 792 +1 (973) 263 4491
Emergency telephone number
(Germany) : +49 621 60-43333
Fax:
(Germany) : +49 621 60-92664

2. Composition/information on ingredients
Substance/Preparation : Preparation
Chemical characterization : Aqueous solution containing: surfactants
To present knowledge of the supplier, this product does not contain any hazardous ingredients in accordance to EU
regulations or National regulations.

3. Hazards identification
The preparation is not classified as dangerous according to Directive 1999/45/EC and its amendments.
Classification :
This product is not classified according to the EU regulations.
Effects and symptoms
Target Organs : Contains material which causes damage to the following organs: skin.

4. First-aid measures
First-Aid measures
Inhalation : If inhaled, remove to fresh air. If not breathing, give artificial respiration. If
breathing is difficult, give oxygen. Obtain medical attention.
Ingestion : Do NOT induce vomiting unless directed to do so by medical personnel.
Never give anything by mouth to an unconscious person. Loosen tight clothing
such as a collar, tie, belt or waistband. Get medical attention if symptoms
appear.
Skin contact : Wash with soap and water. Get medical attention if irritation develops. Cold
water may be used
Eye Contact : Check for and remove any contact lenses. In case of contact, immediately
flush eyes with a copious amount of water for at least 15 minutes. Cold water
may be used. Obtain medical attention.

Date of issue : 10/16/2002. Page: 1/4


AMEROID OSC One Step Cleaner

5. Fire-fighting measures
Extinguishing Media
Suitable : Not applicable.
Hazardous thermal (de)composition : These products are carbon oxides (CO, CO2) and water, nitrogen oxides (NO,
products NO2...), sulphur oxides (SO2, SO3, etc.), phosphates. Some metallic oxides.
Protection of fire-fighters : Fire fighters should wear self-contained positive pressure breathing apparatus
(SCBA) and full turnout gear.

6. Accidental release measures


Personal Precautions : Splash goggles. Full suit. Boots. Gloves. Suggested protective clothing
might not be sufficient; consult a specialist BEFORE handling this product.
Environmental precautions and : Absorb with an inert material and put the spilled material in an appropriate
cleanup methods waste disposal. Finish cleaning by spreading water on the contaminate
surface and allow to evacuate through the sanitary system.
Note: See section 8 for personal protective equipment and section 13 for waste disposal.

7. Handling and storage


Handling : Do not breathe gas/fumes/vapour/spray. If ingested, seek medical advice
immediately and show the container or the label. Keep away from
incompatibles such as oxidizing agents, acids.
Storage : Keep container tightly closed. Keep container in a cool, well-ventilated area.
Packaging materials
Recommended use : Use original container.

8. Exposure controls/personal protection


Engineering measures : Provide exhaust ventilation or other engineering controls to keep the airborne
concentrations of vapours below their respective occupational exposure limits.
Hygiene measures : Wash hands after handling compounds and before eating, smoking, using
lavatory, and at the end of day.

Skin and body : Lab coat.


Eyes : Safety glasses.

9. Physical and chemical properties


Physical state : Liquid.
Colour : Not available.
Odour : Not available.
Boiling point : 100°C (212°F)
Melting point : <0°C (32°F)
Density : 1.14 g/cm3
Vapour pressure : The highest known value is 2.33 kPa (17.5 mmHg) (at 20°C) (Water).
Evaporation Rate : 0.36 (Water) compared to n-Butyl acetate

Solubility : Easily soluble in cold water.


pH : 8.8 [Basic.]
Flash point : Not applicable.

Date of issue : 10/16/2002. Page: 2/4


AMEROID OSC One Step Cleaner

10. Stability and reactivity


Stability : Unstable.
Materials to avoid : Reactive with oxidizing agents, acids.
Hazardous decomposition products : These products are carbon oxides (CO, CO2) and water, nitrogen oxides (NO,
NO2...), sulphur oxides (SO2, SO3, etc.), phosphates. Some metallic oxides.

11. Toxicological information


Acute toxicity
Ingredient Name Test Result Route Species
AMEROID OSC One Step Cleaner LD50 >2000 Oral Rat
mg/kg

Chronic toxicity : Repeated or prolonged exposure is not known to aggravate medical condition.
Carcinogenic effects : Not available.

Mutagenic Effects : Not available.


Reproduction toxicity : Not available.

12. Ecological information

Persistence/degradability : Not available.

13. Disposal considerations


Methods of disposal ; Waste of : Waste must be disposed of in accordance with federal, state and local
residues ; Contaminated packaging environmental control regulations.

European Waste Catalogue (EWC) : 20 01 16


Hazardous Waste : To present knowledge of the supplier, this product is not regarded as
hazardous waste as defined by EU Directive 91/689/EC.
Additional Information : 20 01 16 detergents

14. Transport information


International transport regulations
Land - Road/Railway
UN number : Not regulated.
Proper shipping name : -
ADR/RID Class : -
Other information : Remarks
Not controlled under ADR (Europe).
Sea
UN number : Not regulated.
Proper shipping name : -
IMDG Class : -
Other information : Remarks
Not controlled under IMDG.

Date of issue : 10/16/2002. Page: 3/4


AMEROID OSC One Step Cleaner

15. Regulatory information


EU Regulations
Risk Phrases : This product is not classified according to the EU regulations.
Product Use : Classification and labelling have been performed according to EU directives
67/548/EEC, 88/379/EEC, including amendments and the intended use.
- Industrial applications.

16. Other information


Full text of R-Phrases with no. :
appearing in Section 2 - United
Kingdom (UK)
HISTORY
Date of printing : 10/17/2002.
Date of issue : 10/16/2002.
Version : 3
AMEROID® is a registered trademark of Ashland Inc.
Notice to Reader
To the best of our knowledge, the information contained herein is accurate. However, neither the above named supplier nor
any of its subsidiaries assumes any liability whatsoever for the accuracy or completeness of the information contained
herein.
Final determination of suitability of any material is the sole responsibility of the user. All materials may present unknown