Spindle parameter table 2019/3/28

Customer :
Spindle motor : biI8/12000-B Draw No.A06B-2446-Bxxx
Output Specification nameplate A06B-1230-K446#S0P
Motor sensor : Mi/Mzi #####
Spindle amplifier : αiSP 15-B Draw No.A06B-622x-H015#H6x0
Additional inductance :

Parameter No. Data [Parameter setting procedure]


4006 0000000 300 .
(1)Load parameters automatically with the model code
4007 0000000 Note) If you don't want to initialize adjusted parameters,
4008 00000000 you should not load parameters automatically.
4009 00000000
4010 0
0000000
4011 0
0001101 (2)Change parameters manually according to the table.
4012 0
1000001
4013 0
0000110 (3)Set the sensor parameters.
4019 0
0000010
4398 0
1000000 (4)Power off/on to activate the SPINDLE HRV Control
4400 0
0000000 parameters surely.
4020 0
12000
4039 0 Note) The value marked with *1 in the table should be
4040 3(*1) tuned according to spindle inertia and be treated
4048 12(*1) as the initial value
4080 16220
4083 30
4100 1680
4101 95
4102 2602
4103 0 In case of using the load meter (Normalized by cont. rated output)
4104 4300 ●The load meter (Normalized by cont. rated output)
4105 134 - Set No.4352#3=1, No.4542#7=0
4106 10000 - Set the values shown in the following table
4108 0 No.4127 290
4109 25 No.4612 10836
4110 1331 No.4613 12423
4111 532 ●Smart load meter
4112 200 - No.4352#3=0, No.4542#7=1
4113 714 - Set the values show in above table (for the
4114 21760 Load meter normalized by cont. rated output)
4115 90 - And set the values shown in the following table also
4116 8000
4117 23130 No.4134 110
4118 100 No.4170 456
4119 13 No.4453 1800
4120 0
4124 24575
4127 220
4128 110
4129 0
4130 25700
4134 110
4167 0
4169 0
4334 
4362 -24426
4363 -24076
4364 13038

Maximum power at acceleration(for selecting ai PS) :


16.5kW