PRODUCT SPECIFICATION SHEET

P RO DUCT S PEC I FI C ATI ON SHEET

Span+
PROPRIETARY ITEM CODE: SPNPLS+
Making it Easy

PRODUCT DESCRIPTION
Mounted directly to rafters via stub columns, Con-form Group’s Span+
is a strong, secure and lightweight solution, ideal for when purlin
mounted platforms aren’t an option.

SPECIFICATION WORDING FEATURES AND ADVANTAGES TECHNICAL DATA CERTIFICATIONS


System shall be Con-form Group Span+ allows trusses to span greater distances Prefabricated with 6063-T6 grade Australian Standards: AS/NZS1170,
Span+, proprietary code: SPNPLS+. between rafters. Generations ahead of aluminium components. AS1170.2, AS1657 & AS1664.1 & Relevant
Mounted directly to rafters via stub traditional structural steel platforms. Clauses of the Building Code of Australia
13mm knurled expanded aluminium
columns. Ideal for existing roofs where the purlins simply Wind Loads: Con-form Group products
mesh.
do not have the capacity to adequately support
APPLICATIONS Lightweight from 19kg/m2. Certifications have been certified for wind regions A, B
the equipment on a purlin mounted platform. and C
The Con-form product range has been designed to meet

Perfect for a wide range of industrial Span of 10.5m between rafters or greater.
all standards required. Engineer certifications ensure that

Essential for any roof mounting situation, structural designs comply with the following standards:
V500 = 45m/s - Region A - Tc 2.5
applications: Manufactured in Australia.
Australian Standards - AS1170.1, AS1170.2, AS1657 &
great or small, new or existing, where the client V500 = 57m/s - Region B - Tc 2.5
AS1664.1 & Relevant Clauses of the Building Code of Australia

Con-form Ratings
Large condensors. would like to realise instant savings over costly V500 = 66m/s - Region C - Tc 2.5
Live loads rated to 2.5kPa, 5kPa or greater

traditional mounting. WARRANTY Wind Loads

Packaged air-conditioning units.


Con-form products have been certified
for wind regions A, B and C

Con-form Group’s modular, strong and All components backed by a 25 year


V500 = 45m/s - Region A - Tc 2.5
V500 = 57m/s - Region B - Tc 2.5
A B C
Long spanning airconditioning, V500 = 66m/s - Region C - Tc 2.5

lightweight platform design distributes loads warranty. Acoustic Rating


refrigeration and ventilation Soundshield achieves a Weighted Sound Reduction Index
evenly across the rafters. of Rw (C;Ctr) = 28 (0;-2)

machinery. Peacemaker achieves a Noise Reduction Coefficient (NRC) of 1


Acoustic+ achieves a Weighted Sound Reduction Index of Rw
(C;Ctr) = 33 (0;-2) and Noise Reduction Coefficient (NRC) of 1
Built from lightweight, ultra-strong structural
Other mechanical plant equipment. - Tested by Day Design Consulting Acoustic Engineers at the National Acoustic
Laboratories in accordance with AS/NZS ISO 717.1 2004
grade aluminium, 85% lighter than steel Warranty MAINTENANCE
equivalents. The complete Con-form range is backed by a 20 year warranty

Visual inspection for any damage or loose


Structural grade aluminium design with strong fittings is recommended annually. Report
fixings. any damage or loose fixings to asset
WE OFFER COMPLETE
Built to withstand volatile and extreme weather manager or building owner for correction
ENGINEERING, DESIGN
conditions.
& CONSULTING
SERVICES. Reduction in lead-times and time spent on site.

01
CON -F O R M G RO U P | S p an + Vers i on: V1 Feb 2 0 2 1
PRODUCT SPECIFICATION SHEET

Making it Easy

JOIST - SPACED AT 600/1200 BETWEEN BEARER COLUMNS

CODE HEIGHT OF TRUSS VERT BM VERT SHEAR


[mm] [kNm] [kN]

S4-B-250 250 10.8 21

S4-B-300 350 15.1 21

S4-B-350 400 17.3 21

S4-B-400 450 19.4 21

S4-B-450 450 19.4 21

S4-B-500 500 21.6 21

S4-B-550 550 23.8 21

BEARERS - SUPPORTED BY STUD COLUMNS FIXED ON RAFTERS

CODE HEIGHT OF TRUSS VERT BM VERT SHEAR


[mm] [kNm] [kN]

S4-j-600 600 25.9 21

S4-j-750 750 32.4 21

S4-j-900 900 38.9 21

S4-j-1200 1200 51.8 21

02
CON -F O R M G RO U P | S p an +
PRODUCT SPECIFICATION SHEET

Making it Easy

03
CON -F O R M G RO U P | S p an +
PRODUCT SPECIFICATION SHEET

04
C O N -F O R M G ROUP | S p an +
PRODUCT SPECIFICATION SHEET

05
C O N -F O R M G ROUP | S p an +
A

Notes:
Dimensions shall not be obtained by scaling the draw-
ings. This certification covers the platform only, and does
not cover any surrounding structures.

ALL DIMS. GIVEN IN MM


62 CORPORATION AVE ,BATHURST NSW 2795
info@conformgroup.com.au
1300 882 490 NOT TO SCALE
Product
Span+
Drawing Title Sheet
A ( 1 : 10 ) Technical Data Sheet 1 OF 3
© This Drawing is issued on the understanding that it is Copyright and is to be regarded as confidential property of Con-form Group Pty Ltd. It must not be reproduced without the consent of Con-form Group.
GUARDRAIL

TOP HATS JOIST PLACED AT


600 / 1200 CENTER
BETWEEN BEARERS

DETERMINED
BY
RAFTER SPAN

DEPTH
STUB COLUMN

JOIST

EXISTING I-BEAM

GUARDRAIL

PLATFORM RATED
TO 2.5 / 5.0 kPa

Notes:
Dimensions shall not be obtained by scaling the draw-
ings. This certification covers the platform only, and does
not cover any surrounding structures.

BEARER ALL DIMS. GIVEN IN MM


STUB COLUMN 62 CORPORATION AVE ,BATHURST NSW 2795
info@conformgroup.com.au
1300 882 490 NOT TO SCALE
Product
EXISTING I-BEAM Span+
Drawing Title Sheet
Technical Data Sheet 2 OF 3
© This Drawing is issued on the understanding that it is Copyright and is to be regarded as confidential property of Con-form Group Pty Ltd. It must not be reproduced without the consent of Con-form Group.
9600.00

600.00
7200.00

600.00

Design Certification: Product Options:


The following review has been carried out in accordance with
the following SAI Codes of Practice:
Guard Rail

AS 1657 Fixed Platforms, Walkways, Stairways and Ladders Code


Louvre Screens
AS 1170 Structural Design Actions Code (Parts 0, 1, and 2)
Acoustic Screens
AS 1664.1 Aluminium Structures Code
Equipment Mounting Rails
Structure Importance level 2 (normal structure), in accordance
with the BCA; Architectural Screens Notes:
Dimensions shall not be obtained by scaling the draw-
Super-imposed dead load to platforms = 0.20kPa Access Steps ings. This certification covers the platform only, and does
not cover any surrounding structures.

Fixing Detail*
Fixing for Fixing Type ALL DIMS. GIVEN IN MM
Stainless Steel M8x20mm Cuphead Bolt Set 62 CORPORATION AVE ,BATHURST NSW 2795
NOT TO SCALE
Square/Rectangle Holes info@conformgroup.com.au
1300 882 490
Round Holes Stainless Steel 5.5x20 mm Self Drilling Screw Product

Mesh
Span+
Aluminum Upformed Disc and 5.5 x 35mm Self Drilling Screw
Drawing Title Sheet
Technical Data Sheet 3 OF 3
* Note: these fixing details are for platform construction.
For fixing details to roof, see the EasyFix Range of
© This Drawing is issued on the understanding that it is Copyright and is to be regarded as confidential property of Con-form Group Pty Ltd. It must not be reproduced without the consent of Con-form Group.