WIND LOAD CALCULATION FOR PROPOSED LOADING FOR 14210518(X-DIR)

Shielding FacTor
(+X DIRECTION)

Height From Top

Force Acting
Length (m)

Area (M^2)
Width (m)

Pz
S.N

(m)
L/B Rf Cf Wind Load Each Node (kg) LEG
(Kg/Sqm)

(L1) (L2) (L3) (L4) (L5) (L6)

GSM 1 1.30 0.35 1.500 3.71 0.643 2 156.13 0.455 0.75 68.503383 41 41 41 L1
GSM 2 1.60 0.30 1.500 5.33 0.662 2 156.13 0.48 0.75 74.419264 187 187 187 L1
GSM 3 2.10 0.35 5.000 6.00 0.666 2 150.09 0.735 0.75 110.20772 196 196 196 L1
GSM 4 1.60 0.35 1.500 4.57 0.654 2 156.13 0.56 0.75 85.810733 94 94 94 L2
GSM 5 1.60 0.35 1.500 4.57 0.654 2 156.13 0.56 0.75 85.810733 56 56 56 L2
GSM 6 1.30 0.30 4.000 4.33 0.651 2 152.38 0.39 0.75 58.041411 11 11 11 L2
GSM 7 1.60 0.35 5.000 4.57 0.654 2 150.09 0.56 0.75 82.490874 0 0 0 L3
GSM 8 2.60 0.25 1.500 10.40 0.695 2 156.13 0.65 0.75 105.76922 0 0 0 L4
GSM 9 1.30 0.35 5.000 3.71 0.643 2 150.09 0.455 0.75 65.853113 0 0 0 L4
GSM 10 2.60 0.25 2.000 10.40 0.695 2 153.53 0.65 0.75 104.00562 0 0 0 L5
GSM 11 2.10 0.35 2.000 6.00 0.666 2 153.53 0.735 0.75 112.73148 0 0 0 L5
GSM 12 1.30 0.35 1.500 3.71 0.643 2 156.13 0.455 0.75 68.503383 0 0 0 L6
GSM 13 2.60 0.30 1.000 8.67 0.682 2 156.13 0.78 0.75 124.58482 0 0 0 L6
GSM 14 1.60 0.35 4.000 4.57 0.654 2 152.38 0.56 0.75 83.74786 L6
RRU 1 0.40 0.30 1.500 1.33 0.620 2 156.13 0.12 0.5 11.6163 L1
RRU 2 0.40 0.30 5.000 1.33 0.620 2 150.09 0.12 0.5 11.166887 L1
RRU 3 0.40 0.30 1.500 1.33 0.620 2 156.13 0.12 0.5 11.6163 L2
RRU 4 0.40 0.30 1.500 1.33 0.620 2 156.13 0.12 0.5 11.6163 L2
RRU 5 0.40 0.30 3.000 1.33 0.620 2 153.53 0.12 0.5 11.422609 L2
RRU 6 0.40 0.30 3.000 1.33 0.620 2 153.53 0.12 0.5 11.422609 L2
RRU 7 0.40 0.30 6.000 1.33 0.620 2 150.09 0.12 0.5 11.166887 L2
RRU 8 0.40 0.30 4.000 1.33 0.620 2 152.38 0.12 0.5 11.337046 L3
RRU 9 0.40 0.30 4.000 1.33 0.620 2 152.38 0.12 0.5 11.337046 L3
RRU 10 0.40 0.30 6.000 1.33 0.620 2 150.09 0.12 0.5 11.166887 L3
RRU 11 0.40 0.30 2.000 1.33 0.620 2 153.53 0.12 0.5 11.422609 L4
RRU 12 0.40 0.30 2.000 1.33 0.620 2 153.53 0.12 0.5 11.422609 L4
RRU 13 0.40 0.30 6.000 1.33 0.620 2 150.09 0.12 0.5 11.166887 L4
RRU 14 0.50 0.45 3.000 1.11 0.620 2 153.53 0.225 0.5 21.417392 L5
RRU 15 0.50 0.45 3.000 1.11 0.620 2 153.53 0.225 0.5 21.417392 L5
RRU 16 0.50 0.45 3.000 1.11 0.620 2 153.53 0.225 0.5 21.417392 L5
RRU 17 0.50 0.45 3.000 1.11 0.620 2 153.53 0.225 0.5 21.417392 L5
RRU 18 0.40 0.30 1.500 1.33 0.620 2 156.13 0.12 0.5 11.6163 L5
RRU 19 0.40 0.30 1.500 1.33 0.620 2 156.13 0.12 0.5 11.6163 L5
RRU 20 0.40 0.30 4.000 1.33 0.620 2 152.38 0.12 0.5 11.337046 L6
RRU 21 0.40 0.30 4.000 1.33 0.620 2 152.38 0.12 0.5 11.337046 L6
RRU 22 0.40 0.30 6.000 1.33 0.620 2 150.09 0.12 0.5 11.166887 L6
RRU 23 0.40 0.30 6.000 1.33 0.620 2 150.09 0.12 0.5 11.166887 L6
RRU 24 0.40 0.30 7.000 1.33 0.620 2 148.96 0.12 0.5 11.08229 L6
Height From Top

(+X DIRECTION)
Force Acting
Dia of M.W

Area (M^2)

Pz
S.N

(m)

Cf Wind Load Each Node (kg) LEG


(Kg/Sqm)

(L1) (L2) (L3) (L4) (L5) (L6)

M.W 1 0.6 0.5 0.92 156.13 0.28 40.593348 20 20 20 L2


M.W 2 0.6 0.5 0.92 156.13 0.28 40.593348 36 36 36 L2
M.W 3 0.9 1.5 0.92 156.13 0.64 91.335033 15 15 15 L3
M.W 4 0.6 0.5 0.92 156.13 0.28 40.593348 0 0 0 L4
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0
0