GENERAL NOTES:

1. ALL WOR S SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE PHILIPPINE
ELECTRICAL CODE THE LOCAL ORDINANCES THE RULES AND REGULATIONS OF THE
LOCAL ENFORCING AUTHORITY AND THE RE UIREMENTS OF THE LOCAL POWER COMPANY.
2. ALL WOR S HEREIN SHALL BE DIRECTLY SUPERVISED BY A DULY LICENSED ELECTRICAL
ENGINEER AS ENFORCED BY THE NEW ELECTRICAL ENGINEERING LAW OR R.A. 20.
. ALL WOR S HEREIN SHALL BE DONE IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS.
. ALL MATERIALS TO BE USED SHALL BE BRAND NEW OF THE BEST UALITY AND OF THE APPROVED
TYPE AND SHALL BEAR THE MANUFACTURER S NAME INCLUDING THE PSA MAR . PULL BO ES
SHALL BE PROVIDED IN APPROPRIATE AREAS EVEN IF NOT INDICATED IN THE PLAN.
. POWER SUPPLY TO THE BUILDING SHALL BE SINGLE PHASE.
. RACEWAY SCHEDULE SHALL BE ATLEAST 0 PVC FLE IBLE PIPE

. OUTLET BO ES SHALL HAVE A MINIMUM THIC NESS OF GA. 1 WITH 1/2 O AND SHALL BE
PAINTED WITH RED LEAD PAINT PRIOR TO INSTALLATION.
ACU . WIRES AND CABLES SHALL BE OF THE APPROVED TYPE AND BEARING THE PS MAR UNLESS
C4 SPECIFIED OR INDICATED OTHERWISE. ALL POWER AND LIGHTING CONDUCTORS SHALL BE
INSULATED FOR 00 VOLTS MINIMUM.
. PANELBOARDS SHALL CONFORM TO THE LOAD SCHEDULE AS SHOWN ON PLANS WITH RESPECT
TO BREA ER PHASE ARRANGEMENT RATING CAPACITY AND SHORT CIRCUIT CONSIDERATION.

ELECTRICAL SYMBOL
1-20 W CFL PIN LIGHT

S1 SINGLE POLE SWITCH


S3 THREE GANG SINGLE POLE SWITCH

CONVENIENCE OUTLET

AC SINGLE PHASE AIR COMPRESSOR

w WELDING MACHINE

SERVICE ENTRANCE, COMMUNICATION

C3 C2
PB1 M KILOWATT-HOUR METER

ACU
PANELBOARD
DUPLEX CONVENIENCE OUTLET, GROUNDING TYPE
CIRCUIT BREAKER

SWITCH LINE

FEEDER LINE

POWER OUTLET LAYOUT C CIRCUIT HOMERUN


SCALE 1:1OO

PROJECT TITLE: SHEET CONTENT/S: REVISION/S: APPROVED BY:

E
PTR NO.:

TIN:
DATE:

PRC REGULATON NO.:


LOCATION:
OWNER