Direct Glazing System

Corner Post - Solution (a)

4mm Silicon
Pointing Double
Glazing Unit

4 24 4
10x5mm
EPDM Tape
(set 5mm in)
25minimum

Silicon
Bedding

M6x100 S/S Countersunk


Posidrive Woodscrew
19mm Counterbore & 200x200
Crossgrain Pellet Main Post

Ex 100x100 Air Dried


Oak Corner Piece
PAR
S/W Packer
32x175 Air Dried
Oak Capping (heart out)

Notes:

All capping timber must be joinery grade air-dried oak


All screws must be stainless steel (counter-bored and pelleted where visible)
Flashings, spacer bar and pointing colours to be specified by architect
Standard double glazed units 24mm thick (4mm k glass inner leaf + 16mm spacer bar + 4mm glass outer leaf) or equivelant
Special roof glazing units 24mm thick (6mm laminated k glass inner leaf + 12mm spacer bar + 6mm toughened solar glass outer leaf) or equivelant Sheet 1
Direct Glazing System
Corner Post - Solution (b)

4mm Silicon
Pointing Double
Glazing Unit

4 24 4
10x5mm
EPDM Tape
(set 5mm in)
25minimum

Silicon
Bedding

M6x100 S/S Countersunk


Posidrive Woodscrew
19mm Counterbore &
Crossgrain Pellet 200x200
Main Post

32x45 Air Dried


Oak Packer PAR
32x150 Air Dried S/W Packer
Oak Capping (heart out)

Notes:

All capping timber must be joinery grade air-dried oak


All screws must be stainless steel (counter-bored and pelleted where visible)
Flashings, spacer bar and pointing colours to be specified by architect
Standard double glazed units 24mm thick (4mm k glass inner leaf + 16mm spacer bar + 4mm glass outer leaf) or equivelant
Special roof glazing units 24mm thick (6mm laminated k glass inner leaf + 12mm spacer bar + 6mm toughened solar glass outer leaf) or equivelant Sheet 2
Direct Glazing System
Post / Stud / Mullion

Silicon
Bedding
10x5mm 150x150
EPDM Tape Stud
(set 5mm in)

4mm Silicon
Pointing 25minimum
4
24
4
32

PAR
Double
S/W Packer
Glazing Unit

M6x100 S/S Countersunk 32x150 Air Dried


Posidrive Woodscrew Oak Capping
19mm Counterbore & (heart out)
Crossgrain Pellet

Notes:

All capping timber must be joinery grade air-dried oak


All screws must be stainless steel (counter-bored and pelleted where visible)
Flashings, spacer bar and pointing colours to be specified by architect
Standard double glazed units 24mm thick (4mm k glass inner leaf + 16mm spacer bar + 4mm glass outer leaf) or equivelant
Special roof glazing units 24mm thick (6mm laminated k glass inner leaf + 12mm spacer bar + 6mm toughened solar glass outer leaf) or equivelant Sheet 3
Direct Glazing System
Door/ Window Post

10x5mm
EPDM Tape
(set 5mm in)
Door Jamb
Silicon
Bedding
150x150
Stud
Hardwood Door/ Window

4mm Silicon
Pointing

25minimum
Double
Glazing Unit
PAR
S/W Packer

M6x100 S/S Countersunk 32x150 Air Dried


Posidrive Woodscrew Oak Capping
19mm Counterbore & (heart out)
Crossgrain Pellet

Notes:

All capping timber must be joinery grade air-dried oak


All screws must be stainless steel (counter-bored and pelleted where visible)
Flashings, spacer bar and pointing colours to be specified by architect
Standard double glazed units 24mm thick (4mm k glass inner leaf + 16mm spacer bar + 4mm glass outer leaf) or equivelant
Special roof glazing units 24mm thick (6mm laminated k glass inner leaf + 12mm spacer bar + 6mm toughened solar glass outer leaf) or equivelant Sheet 4
Direct Glazing System
Sill Plate

4mm Silicon Double


Pointing Glazing Unit

32 4 24 4
10x5mm
EPDM Tape
(set 5mm in)
25minimum

Silicon
Bedding

M10x150 S/S Countersunk 200x125


Posidrive Woodscrew Sill Plate
30mm Counterbore &
Crossgrain Pellet

Ex 70x125 Air Dried


Oak Capping (heart out)

PAR
S/W Packer

Notes:

All capping timber must be joinery grade air-dried oak


All screws must be stainless steel (counter-bored and pelleted where visible)
Flashings, spacer bar and pointing colours to be specified by architect
Standard double glazed units 24mm thick (4mm k glass inner leaf + 16mm spacer bar + 4mm glass outer leaf) or equivelant
Special roof glazing units 24mm thick (6mm laminated k glass inner leaf + 12mm spacer bar + 6mm toughened solar glass outer leaf) or equivelant Sheet 5
Direct Glazing System
Tie Beam / Floor Girt

Double 4mm Silicon


Glazing Unit Pointing

10x5mm
Ex 45x120 Air Dried EPDM Tape
Oak Capping 4 24 4
(set 5mm in)
(heart out)

4mm Silicon
Bedding

PAR
S/W Packer

M6x100 S/S Countersunk


Posidrive Woodscrew
19mm Counterbore &
Crossgrain Pellet

225x150
Tie Beam
Note: Tie Beam
6

Cap in two pieces


to avoid cupping

32x95PAR
S/W Packer
25minimum

Ex 45x125 Air
Dried Oak Capping
(heart out)

Notes:

All capping timber must be joinery grade air-dried oak


All screws must be stainless steel (counter-bored and pelleted where visible)
Flashings, spacer bar and pointing colours to be specified by architect
Standard double glazed units 24mm thick (4mm k glass inner leaf + 16mm spacer bar + 4mm glass outer leaf) or equivelant
Special roof glazing units 24mm thick (6mm laminated k glass inner leaf + 12mm spacer bar + 6mm toughened solar glass outer leaf) or equivelant Sheet 6
Direct Glazing System
Top Plate - Conventional Roof

200x125
Top Plate

M6x100 S/S Countersunk


Posidrive Woodscrew
19mm Counterbore &
75x75 Oak Bead Crossgrain Pellet

Silicon
Bedding

10x5mm
EPDM tape
Ex 45x105 Air 32 4 24 4 (set 5mm in)
Dried Oak Capping
(heart out)
4mm Silicon
PAR Pointing
S/W Packer
Double
Glazing Unit

Notes:

All capping timber must be joinery grade air-dried oak


All screws must be stainless steel (counter-bored and pelleted where visible)
Flashings, spacer bar and pointing colours to be specified by architect
Standard double glazed units 24mm thick (4mm k glass inner leaf + 16mm spacer bar + 4mm glass outer leaf) or equivelant
Special roof glazing units 24mm thick (6mm laminated k glass inner leaf + 12mm spacer bar + 6mm toughened solar glass outer leaf) or equivelant Sheet 7
Direct Glazing System
Top Plate - Warm Deck Roof

er
Raft
on
m
om
kC
Oa
00
x1
75

200x125
M6x100 S/S Countersunk Top Plate
Posidrive Woodscrew
19mm Counterbore &
Crossgrain Pellet

Silicon
Bedding

10x5mm
EPDM tape
32 4 24 4 (set 5mm in)
Ex 45x125 Air Dried
Oak Capping
(heart out) 4mm Silicon
PAR Pointing
S/W Packer
Double
Glazing Unit

Notes:

All capping timber must be joinery grade air-dried oak


All screws must be stainless steel (counter-bored and pelleted where visible)
Flashings, spacer bar and pointing colours to be specified by architect
Standard double glazed units 24mm thick (4mm k glass inner leaf + 16mm spacer bar + 4mm glass outer leaf) or equivelant
Special roof glazing units 24mm thick (6mm laminated k glass inner leaf + 12mm spacer bar + 6mm toughened solar glass outer leaf) or equivelant Sheet 8