QUICK REFERENCE

GUIDE
Connectivity to
the mySugr® app

WARNING
The Accu-Chek Instant meter
Meter button and Accu-Chek FastClix finger
pricker are intended for patient
self monitoring by an individual
person only. They must not be
Target Range used to test blood glucose from
more than one person as they do
Indicator not incorporate any features to
Strip guard against cross-infection.
ejection
button WARNING
This Quick Reference Guide
does not replace the detailed
User Manual for your
Strip port Test strip Accu-Chek Instant blood
glucose monitoring system. Be
sure to comply with the safety
information in the User Manual
and in the package insert of the
test strip.

PERFORMING A BLOOD GLUCOSE TEST


WITH BLOOD FROM YOUR FINGERTIP
NOTE
• You need the meter, Accu-Chek Instant test strip, and a lancing device with a lancet inserted to perform a blood glucose test.
• A blood glucose test cannot be performed while the meter is connected to a PC with a USB cable.

1 2 9
Wash your hands with Check the use by date on Your test result appears with an arrow. This arrow shows
warm soapy water and the test strip container. if your test result falls above, within, or below the target
dry thoroughly. Prepare Do not use test strips past range.* The target range is represented by the green
the lancing device. the use by date. region of the target range indicator. The arrow will flash if
3 4
your test result falls above or below this range.
Remove a test strip from Insert the metallic end of Remove and discard the used test strip by pulling the test
the test strip container. the test strip into the meter. strip out of the meter or by pushing the test strip ejector on
Close the cap tightly. The meter turns on. the side of the meter.
Blue *The target range is set by
Test result is default at 3.9–8.9 mmol/L.
5 6 above the To change the target
When a flashing drop Gently squeeze your target range.
range, pair the meter to a
symbol appears, perform finger to assist the blood Green mobile device, or connect
a fingerstick with the flow. This helps you get a Test result is it to a PC with diabetes
within the management software
lancing device. blood drop. target range. installed.
Consult your healthcare
7 8 Red
professional before
Test result is
Touch the yellow edge of the Remove your finger from the below the changing the target range.
test strip to the blood drop. test strip when the flashing target range.
Do not put blood on top of the hourglass symbol appears.
test strip. Failure to move your finger Press to eject test strip
away from the test strip could A strip ejector for quick,
hygienic removal.
give inaccurate test results.
SETTING THE TIME AND DATE
1 2 3 4
NOTE
The meter prompts you to set the time
and date the first time you turn the
meter on or if an error occurs.
• Press and hold down at any time
until the flashing test strip symbol
appears to perform a test.
• The time and date on the meter
Press up to turn the Press and hold down Press and hold up to Repeat step 3 to adjust
synchronizes to the time and date on
meter on. until set‑up appears set the hour and move each field. After setting
the paired device each time the meter
on the display. The to the next field. The the year, press and hold
sends data to the paired device. See the
hour flashes. Press up minutes flash. Press up until the flashing
chapter Wireless Communication and
to increase the hour up to increase the test strip symbol appears
Meter Pairing in your User Manual.
or press down to minutes or press down to save your settings.
decrease the hour. to decrease the minutes.
CHANGING THE BATTERIES
1 2 3
NOTE
• Always have a spare set of batteries.
• Battery life may vary due to factors such as temperature and
battery manufacturer.
• The meter uses two 3‑volt lithium batteries, coin cell type CR2032.
This type of battery can be found in many stores.
Open the child-resistant Remove the old Slide the new • Always replace both batteries at the same time and with the
battery door by inserting batteries. Press and batteries under the same brand.
a narrow object, such hold for at least 2 tabs with the (+) • Meter data is not lost when you replace the batteries.
as a pen, into the slot seconds. side facing up. Put
(see image above). Push the battery door back WARNING
the tab in the direction in place and snap it Keep new and used batteries away from children.
of the arrow and lift the closed. Immediately See the warning in the Introduction of your User Manual for
battery door up. discard the old batteries. additional information.

SETTING UP THE LANCING DEVICE


1 2 3

WARNING
You must not insert
the lancet drum into
the lancing device and
simultaneously press the
release button or hold the
lancing device with the
release button resting on
a surface such as a table
Familiarise yourself with Get the lancet drum NOTE Remove the cap by pulling top. This could release a
the Accu-Chek FastClix from the pocket in the Each lancet drum contains it straight off. lancet and inadvertently
lancing device. carry case. 6 sterile lancets. Do not twist the cap. cause injury.
4 5 6 7

Insert the lancet drum, NOTE Replace the cap on Adjust the lancet depth to Using the Accu-Chek
white end first, into the Do not remove the lancet the lancing device. Make a comfortable penetration FastClix lancing device: By
lancing device. Push the drum until all 6 lancets have sure the notch on the cap level. Start at 2 or 3. For pressing the release button,
lancet drum all the way been used since the lancet lines up with the notch on tougher skin, dial to a the lancing device primes
in until it clicks firmly drum cannot be reused the lancing device. higher number. and pricks in 1-Click action.
into place. once it has been removed
from the lancing device.

If you need any more help or information please contact your Roche Diabetes Care representative.
© 2020 Roche Diabetes Care Limited. All rights reserved.
ACCU-CHEK, ACCU-CHEK INSTANT, FASTCLIX and MYSUGR are trademarks of Roche.
All other trademarks or brand names are the property of their respective owners.
Roche Diabetes Care Limited, Charles Avenue, Burgess Hill, West Sussex, RH15 9RY, UK.
Company Registration Number 9055599
For use in the UK & Ireland only
Date of preparation: November 2020
Material Number: 09426493001
www.accu‑chek.co.uk www.accu‑chek.ie

You might also like