New VC0-Report
New VC0-Report
Project: ferme
Variant: Nouvelle variante de simulation
Standalone system with batteries
System power: 500 Wp
FermeHay Marjane Deux - Morocco
Author
Project: ferme
Variant: Nouvelle variante de simulation
PVsyst V7.4.0
VC0, Simulation date:
07/12/23 22:49
with v7.4.0
Project summary
Geographical Site Situation Project settings
FermeHay Marjane Deux Latitude 33.86 °N Albedo 0.20
Morocco Longitude -5.57 °W
Altitude 547 m
Time zone UTC
Meteo data
fermeHay Marjane Deux
Meteonorm 8.1 (1996-2015), Sat=100 % - Synthétique
System summary
Standalone system Standalone system with batteries
System information
PV Array Battery pack
Nb. of modules 2 units Technology Lead-acid, sealed, AGM
Pnom total 500 Wp Nb. of units 8 units
Voltage 24 V
Capacity 488 Ah
Results summary
Useful energy from solar 793.17 kWh/year Specific production 1586 kWh/kWp/year Perf. Ratio PR 73.13 %
Missing Energy 50.18 kWh/year Available solar energy 885.44 kWh/year Solar Fraction SF 94.05 %
Excess (unused) 69.18 kWh/year
Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Predef. graphs 7
PVsyst V7.4.0
VC0, Simulation date:
07/12/23 22:49
with v7.4.0
General parameters
Standalone system Standalone system with batteries
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 32 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate
User's needs
Daily household consumers
Seasonal modulation
Average 2.3 kWh/Day
PV Array Characteristics
PV module Battery
Manufacturer Generic Manufacturer Rolls
Model Mono 250 Wp 60 cells Model S12-160 AGM
(Original PVsyst database) Technology Lead-acid, sealed, AGM
Unit Nom. Power 250 Wp Nb. of units 4 in parallel x 2 in series
Number of PV modules 2 units Discharging min. SOC 20.0 %
Nominal (STC) 500 Wp Stored energy 9.2 kWh
Modules 2 Strings x 1 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 24 V
Pmpp 450 Wp Nominal Capacity 488 Ah (C10)
U mpp 27 V Temperature Fixed 20 °C
I mpp 16 A
Total PV power
Nominal (STC) 0.500 kWp
Total 2 modules
Module area 3.3 m²
Cell area 2.8 m²
Array losses
Thermal Loss factor DC wiring losses Serie Diode Loss
Module temperature according to irradiance Global array res. 28 mΩ Voltage drop 0.7 V
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC Loss Fraction 2.3 % at STC
Uv (wind) 0.0 W/m²K/m/s
PVsyst V7.4.0
VC0, Simulation date:
07/12/23 22:49
with v7.4.0
Hourly distribution
PVsyst V7.4.0
VC0, Simulation date:
07/12/23 22:49
with v7.4.0
Main results
System Production
Useful energy from solar 793.17 kWh/year Perf. Ratio PR 73.13 %
Available solar energy 885.44 kWh/year Solar Fraction SF 94.05 %
Excess (unused) 69.18 kWh/year
Loss of Load Battery aging (State of Wear)
Time Fraction 5.5 % Cycles SOW 94.8 %
Missing Energy 50.18 kWh/year Static SOW 90.0 %
Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy
PVsyst V7.4.0
VC0, Simulation date:
07/12/23 22:49
with v7.4.0
Loss diagram
1904 kWh/m² Global horizontal irradiation
+14.0% Global incident in coll. plane
PVsyst V7.4.0
VC0, Simulation date:
07/12/23 22:49
with v7.4.0
Predef. graphs
Diagramme d'entrée/sortie journalier