Borehole Data Capture Sheet USER FORMS
SITE EQUIPMENT
Dipper
Cap Key
Bucket
Leveloader + cable
Rio Tinto FORM SHEET FOR SLUG TESTS
MOZAMBIQUE Pz = Piezometer See List Below
Mz = Mozambqiue
S## = Station ID
PIEZOMETER USE in Slug Test Logger
Groundwater Station ID Pz-Mz- Project_ID Groundwater Stn ID
Logger_ID (Serial Number) Location “Slug Test:Stn_ID”
DATE (YYYY/MM/DD) of Slug Test
LOGGER_ID for Slug Test 1054920
Logger Program # (USE 10s ec scan rate)
LOGGER_ID for water supply 1054914
Logger Program # (Use 10 sec scan rate)
DATE (YYYY/MM/DD)
TIME (HH:MM:SS)
Dipper Water Level BEFORE TEST
ADD water at maximum rate for 1 minute
Check when WL reaches Pre-Test level ± 1cm
ADD water at maximum rate for 2 minute ▼
Check when WL reaches Pre-Test level ± 1cm
ADD water at maximum rate for 3 minute Water
STOP TEST WHEN WL REACHES Pre-Test Level ± 1cm Tank
Withdraw loggers from tank/well and STOP them with Leveloader
NOTE
Discharge into piezometer at maximum rate without causing air blocks or
surges in the discharge rate. If case fills then immediately stop the water
and start to monitor the recession rate
Pz-Mz-M## LOGGER_ID REQUIREMENTS
Bp-Mz-M00 1053517 Full Water Tank
Pz-Mz-M00 1054920 2 loggers
Pz-Mz-M01 1054911 2 buckets
Pz-Mz-M02 1054863 WL Dipper
Pz-Mz-M03 1054898 Pre-program loggers (use program #2)
Pz-Mz-M04 1054857 30 sec scan rate
Pz-Mz-M05 1054900
Pz-Mz-M06 1054868 PROCEDURE
Pz-Mz-M07 1054870 Dipper Water Level
Pz-Mz-M08 1054865 Remove Site Logger into bucket
Pz-Mz-M09 1054907 Record Logger_IDs
Pz-Mz-M10 1054871 Insert logger #1 to just below WL
Pz-Mz-M11 1054923 Insert logger #2 to bottom water tank
Pz-Mz-M12 1054896 Place discharge pipe into casing
Pz-Mz-M13 1054913 Record date & time
Pz-Mz-M14 1054904 Open valve until tank level drops 25%
Pz-Mz-M15 1054873 Close valve
testing 1054914 Monitor WL till it returns to ±10cm start leve
COMMENTS Open valve until tank level drops to 50%
Close valve
Monitor WL till it returns to ±10cm start leve
Repeat test #3 if sufficient water WL ▼