ACCEPTANCE TEST - RING

OTDR / ATTENUATION MEASUREMENT

FO LINK / AREA Ring ID BCBHRA30S1 Location A B237 Kembaran


Span ID B237 to JAW-JT-PWT-1765 Location B JAW-JT-PWT-1765 LTE_DUKUHWALUH

CABLE ROUTE SECTION/SPAN B237 to JAW-JT-PWT-1765 TOTAL CABLE LENGTH (km) 3,394
FO LINK BCBHRA30S1 OPERATING WAVE LENGTH 1550 nm
CABLE TYPE LOOSE TUBE ATTENUATION (dB/km) 0,28
NUMBER OF FIBER 96 REFERENCE (Avg ATT*Cable Length) 0,95
NUMBER OF SPLICE (JOINT) 3 OTDR TYPE F2H FHO500
FO CABLE
OPTICAL LENGTH ATTENUATION A-B ATTENUATION B-A AVG ATTENUATION
LOOSE TUBE/ FIBER COLOUR Pass/ Fail REMARKS
FIBER# (KM) (dB) (dB) (dB/Km)
RIBBON#
9 Yellow 3,394 0,985 1,564 0,081 PASS
10 Violet 3,394 0,776 0,580 0,095 PASS
11 Rose 3,394 0,829 0,764 0,060 PASS
12 Aqua 3,394 1,239 1,236 0,070 PASS

Y N
As Build Drawing:
OTB Photo:
Berita Acara dg TP: (silahkan buat sendiri)

*) Pass if Average ATT <= Reference (Total Cable Length*ATT)