Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Name of Product : GE Senographe Pristina 3D DBT Stereotaxy with Senoiris

Brand : GE
Manufacture : France

Features
Ergonomic design for technologists
• Re-imagined user interface
• One touch access to preset rotation for positioning
• Variable speed motorized gantry movements
• Sliding compression paddles can move to the side of the detector for compression of any breast in any view

Enhanced patient comfort


• Patient friendly design
• Ergonomic integrated bucky
• Easy wheelchair access
• Rounded edges detector for patient comfort

Outstanding image quality


• Enhanced Detective Quantum Efficiency (DQE)
• Molybdenum/Rhodium dual track tube
• Automatic Optimization of parameters (AOP) transparently selects all parameters based on breast radiological properties
• AOP modes enable more flexibbility in dose management
• Enhanced conspiculty with fine view and improved contrast with premium view

Advanced Applications
• Digital Breast Tomosynthesis (Included)
• Stereotaxy Biopsy (Included)

Technical Specifications
Detector 24 x 29 cm
Acquisition dynamic range: 14 bits
• Cooling system : Closed loop liquid cooling

X-Ray Tube
Dual track: Molybdenum (Mo) enriched with Vanadium, and Rhodium
• Anode target materials :
(Rh)
• Focal spots: 0.1 and 0.3 IEC on each target
• Maximal high voltage: 49 kV
• Anode heat storage capacity: 250 kJ (340 kHU)
• Weight: 7 kg

Grid/breast support
• Ergonomic breast support for patient comfort and easy
Yes
cleanability
• Motorized installation and removal of the grid and breast
Yes
supportfor geometric
• Breast support material: low attenuation carbon fiber composite

Exposure control
Automatic Exposure
• Automatic Optimization of Parameters (AOP) is a fully automatic exposure system that selects all exposure parameters based on
radiological density of the breast for

Manual mode
• Manual selection of all parameters: track, filter, kV and mAs

Collimator
• Filter: Molybdenum: 0.030 mm; Rhodium: 0.025 mm
• FOV selection : automatic and manual

Compression
Compression modes: – Motor driven compression up to 20 daN
• Dual foot-pedals for column height and compression adjustments Yes
• User defined motorized compression force limit: 4 to 20 daN
• Min force for AOP: 3 daN
• Compression speed: 3 speed levels

Safety features
• Gantry locked when compression force applied
Positioner
• C-arm with motorized rotation and vertical movement Isocentric arm with motorized rotation and vertical movement
• Source to image receptor distance: 660mm
• Floor to image receptor distance: from 65 cm to 150 cm
• Rotation angle: - 180 / 180 degrees
two on both sides of the tube arm and two additional handles at the
• Ergonomic Handle:
detector level

User Interface
• Four sets of single speed switches for rotation, angulation, and lift movements, with an accelerating speed profile
• Four sets of preset position buttons for quick and easy positioning in CC and MLO
• Automatic stop at +/- 90 degrees for lateral positions
• Collimation buttons on the tube head for field of view size and location
– Tube arm support rotation angle
• Parameters display – Compressed breast thickness (in mm)
– Compression force (in daN)
– Controls exposure
• Ergonomic control console – Provides information on system status
– Gives access to advanced parameters for system set-up
• Patented automatic view names marking based on breast laterality
• View name can be edited while the exam is performed

Acquisition Workstation
• Small footprint
• Dose calculated and displayed on the image after every exposure (Entrance Skin Dose and Average Glandular Dose)
• Time to display processed image (average): 10 seconds
• Time between exposures (typical): 12 seconds

Connectivity
– Modality Worklist User
– Storage Provider
– Storage Commitment User
• DICOM 3.0 platform: – Query/Retrieve User
– Basic Grayscale Print User
– Verification Provider
– DICOM-compliant CD-RW Data Interchange and USB Data
customizable Autopush to multiple DICOM databases, Autoprint,
• Connectivity features:
Autodelete based
• Modality Perform Procedure Step User
• Connectivity to GE Service for remote diagnostic capability

Radiation shield
• Radiation shield

High voltage generator


• Generator type: high frequency single-phase power supply
• Power: 5 kW max
• mAs range: 2 to 600 mAs (depending on track, filter and kV)
• kV range: 22 to 49 kV, in 1 kV steps depending on track

Power supply
• Input frequency: 50/60Hz
• Input voltage: single-phase 200-240 V

Product Composition :
• Main Unit with manual and automatic compression
• Acquisition Workstation with Radiation Shield
• 19X23 Sliding Paddle
• 19X23 Flexible Sliding Paddle
• 24X29 Flexible Paddle
• Magnification Device
• Advanced Application 3D / DBT
• Advanced Application Stereotaxy Biopsy with Horizontal Approach
• Senoiris 5MP Monitor - Review Workstation
• Printer - Non GE
• UPS 10 kVA - Non GE

You might also like