Vehicle Estimate

Design Rev. November 5, 2015 Last Rev. November 28, 2018


Equipment Info: Atlas Copco 270 Blast Hole Drill
Engine HP: 596 Vehicle Weight: 185,000 LB
No. of Engines: 1 Design Per: BC/BM
Engine Type/Model: C27 Acert (2) 8" Turbos Drawing No.: 60049
DOT & TC Certification
DC Standard. DC Extend
System DC Tanks:
Nozzles: Nozzles:
LVS Tanks: LVS Nozzles:
Summary: 0 0 2 35

Qty. Part No Description


1 LVS Tanks
2 438821 LVS-30 Tank Assy. and 55 cu. Ft. N2 Cartridge
1 Mounting Rings & Tank Brackets
2 428405 Mounting Ring, LT-A-101-250, LVS-30
1 LVS Agent
12 426961 LVS Suppressant, 5 gallon pail (18.9 L)
1 Distribution & Fittings
2 438835 Manifold Block, 4 x 1 Outlet, Distribution (LVS)
1 Nozzles
35 433325 Nozzle, LVS 9.5 with Blow-Off Cap, L-Bracket, 2 Lock Washers
1 CHECKFIRE System
1 439561 ICM Assembly CHECKFIRE-210
1 439560 Display Module Assembly, CHECKFIRE-210
1 439564 Display Module Bracket Assembly, CF110/CF210
1 440352 Battery Shipping Assembly., CF210
1 447044 ICM Cable Clamp
2 448754 Electric Manual Actuator W/Pigtail
2 440537 Bracket EMA Shipping Assembly
2 439448 Protracting Act. Device, w-Spade Conn.(PAD)
1 440798 CHECKFIRE NEXT GEN Label Ship. Assembly
1 Detection Circuit
1 439384 Cable Assy., Detection Circuit 2 ft (0.61 m)
1 439388 Cable Assy., Detection Circuit 10 ft (3.05 m)
1 439390 Cable Assy., Detection Circuit 20 ft (6.10 m)
2 446539 Detection "h" Cable
2 439396 Connector, End-of-line, Detection Circuit (EOL)
1 Linear/Spot Detectors
2 439408 Cable Assy., Linear Detector 20 ft (6.10 m)
1 440765 Cable Assy., Linear Detector 50 ft (15.24 m)
1 Release Circuit
1 439418 Cable Assy., Release Circuit 2 ft (0.61 m)
1 439420 Cable Assy., Release Circuit 5 ft (1.53 m)
2 439422 Cable Assy., Release Circuit 10 ft (3.05 m)
2 439430 Cable Assy., Release Circuit Drop-30 in.
1 446542 Release "h" Cable

1
Atlas Copco 270 Blast Hole Drill

Qty. Part No Description


1 Power Circuit
1 439438 Cable Assy., Power Circuit 2 ft (0.61 m)
1 439444 Cable Assy., Power Circuit 20 ft (6.10 m)
1 439492 Cable Assy., Fused Power Circuit Cable 3 ft (0.91 m)
1 Display Cable
1 443538 Cable Assy., Bus 10 ft (3.05 m)
1 443539 Cable Assy., Bus 20 ft (6.10 m)
1 Relay Cable
1 439482 Cable, Relay Circuit 10 ft (3.05 m)
1 439466 Cable Assy, Relay Circuit Cable - Leads 3 ft (0.91 m)
1 Extinguishers
1 30759 Bracket, Extinguisher, LT-A-20-G-1
1 435129 Extinguisher, LT-A-20-G-1
1 Accessories
1 448174 Bulkhead Cord Grip, (50 Pack)
1 447928 Grommet, 3-Hole (25 Pack)
1 447931 Grommet, 2-Hole (Display/Bus)(25 Pack)
1 447321 Grommet, (Linear Detector)(25 Pack)
1 440737 Double Loop Nylon Cable Ties (50 Pack)

PLEASE NOTE THAT NON ANSUL® PARTS WILL BE REQUIRED TO


COMPLETE THE INSTALLATION

IMPORTANT NOTES:
Although recommended, the hand portable fire extinguisher(s) is not an integral component for the vehicle system. This Vehicle Estimate is intended as a
reference for quotation purposes only. Additional protection may be required. An on-site hazard analysis will be needed to verify the protection requirements.
For additional nozzle locations, and descriptions refer to the detailed drawing, if available. The CHECKFIRE Detection and Actuation? System is an
estimation intended to assist in quotation purposes only. The provided Estimate will require confirmation and/or modification based on the on-site hazard
analysis to help ensure proper protection.

DISCLAIMER:
This information is conceptual in nature and is to be used only as a guideline for quotation purposes. The fire suppression system depicted on this sheet
was prepared with information provided from vendor’s sales literature, from comparisons of similarly used vehicles of comparable size and capacity, from
designs created by Authorized ANSUL® Distributors, or from the on-site design created by Johnson Controls. The system constitutes nominal hardware
requirements considering the vehicle layout and accessories provided at the time of design. Because variations of this vehicle model, uncontrolled vehicle
design change, and/or unknown accessory options included, this design may not be completely adequate for the equipment model number identified above.
The final fire suppression system design cannot be determined until the in-depth hazard analysis has been performed on the vehicle to be protected. The
fire system described in this material is a suppression system only and cannot be designed nor is it intended to extinguish all possible fires. Certain
situations can result in fire conditions which exceed the suppressing capacity of the ANSUL A-101/LVS system, for example: unusual amounts of
combustible materials and flammable fuels present, hydraulic, brake and steering fluids under high pressure extremes, uncontrolled operating and
environmental conditions, and extended vehicle operating periods with minimal vehicle maintenance. Alternative firefighting equipment will need to be
available to supplement the system if re-ignition occurs.