Abstract:
Background: The effects of electronic cigarettes on the ocular surface has yet to be shown. The purpose of the study was to
assess the impact of e-cigarette use on the anterior corneal surface integrity.
Methods: Forty three males and 21 females with an average of 21years were required to vape 0.05ml of e-liquid of 8mg nicotine
concentration. Corneal epithelial thickness (CET) and Non Invasive Keratograph Tear Break up Time (NIKBUT) measure-
ments were obtained prior to and post vaping. The Optovue iVue optical coherence topographer was used to measure central;
superior; inferior; nasal and temporal CET and NIKBUT was assessed using the Oculus Keratograph 5M.
Results: There was a mean increase for central corneal epithelial thickness of 0.3448 microns. The superior CET increased
by 0.2414 microns. The inferior CET increased by 0.2931microns. The nasal CET increased by 0.2069 microns. The temporal
CET increased by 0.2759 microns. The mean change in NIKBUT post-vaping was an increase of 1.40 seconds. All observations
occurred at p > 0.05.
Conclusion: The acute effect of e-cigarette use does not impact corneal epithelial thickness and non-invasive keratography tear
break up time after 10 puffs mild exposure but more research is needed to assess if this remains the case with more frequent,
higher exposure.
Keywords: Pre-test post-test assessment, non-invasive keratograph breakup time, corneal epithelial thickness, vaping.
DOI: https://dx.doi.org/10.4314/ahs.v19i4.13
Cite as: Munsamy A, Bhanprakash B, Sirkhot A, Mlambo L, Dlamuka S, Mhlongo N, Naidoo R. A pre-test post-test assessment
of non-invasive keratograph break up time and corneal epithelial thickness after vaping. Afri Health Sci. 2019;19(4):2926-2933. https://
dx.doi.org/10.4314/ahs.v19i4.13
Table 1 shows the mean change for central corneal epithe- thickness was -0.2931 microns with a statistically insignif-
lial thickness was -0.3448 microns which was statistically icant p-value of 0.169. The mean change for nasal corne-
insignificant with a p-value of 0.105. The mean change al epithelial thickness was -0.2069 microns with a statisti-
for superior corneal epithelial thickness was -0.2414 mi- cally insignificant p-value of 0.269. The mean change for
crons which was statistically insignificant with a p-value temporal corneal epithelial thickness was -0.2759 microns
of 0.230. The mean change for inferior corneal epithelial with a statistically insignificant p-value of 0.117.
Figure 2: Box and whisker plot for Average NIKBUT before and after vaping 0.05ml of e- liquid.
Table 2: Mean change (microns) in average NIKBUT after vaping 0.05ml of e-liquid.
A negative reading implies an increase in NIKBUT and a positive reading implies decrease.