Download as pdf or txt
Download as pdf or txt
You are on page 1of 15

50076252

Copyright (D) KONE Corporation 2014 KMI (BUI) Screen Map

Indicates that Lift


has connection to
Group Controller Menu
Default Screen Speed

Accept

Indicates that Lift Fault Code


Active Fault List
Fault Active
is under Group
Menu & Timeout Timeout
Control (In Bank)
Menu Timeout
OR
!Fault Active

Fault Log Fault Log Operation Selection Fault List Fault Code
Accept Accept Timeout
Menu Menu Timeout
Fault Log Clearing

Menu

Elevator Parameters Parameter ID Selection Parameter Vector Selection Parameter Value Edition
Accept
Menu
Menu 2 available, If the parameter is not vector this
if param state is skipped
DRIVE_TYPE = 1 Menu Dot indicates if parameter is vector
(Serial Drive) Encoder Polarity
Drive Parameters

(Detailed flow diagram


Motor Phase Polarity available in sheet – ‘Drive
Parameters’ )

LWD Type
Menu

Floor Markings Floor Marking Floor Selection Floor Marking Editing

Menu
Display and Tests Selection Start Counter
Menu

Display and Tests


KCECPU Version Number

KEN Number

Menu DTS Time LWD setup points available


only for KDL (Serial) drive

Comissioning Comission Selection LWD Adjustment LWD setup

Safe Well Access


Detailed flow diagram available with sheet
(Detailed flow
– ‘Safe Well Access’ )
diagrams
Roll Call and LON Download available with
Menu sheets – ‘lwd
Menu 8 - Group Indicates that Lift setup with 3
available, if param has connection to Selecting Factory Default Parameters
points’, ‘Set
GROUP_TYPE = 1 Group Controller Empty LWD’, ‘Set
Group Half LWD’ and
Group Default Screen
‘Set Full LWD’ )

Menu 9 available, if param


DRIVE_TYPE = 1 (Serial Drive) Menu Indicates that Lift is under
Group Control (In Bank)
Drive Tests

(Detailed flow diagram available


with sheet – ‘Drive Tests’ )
BUI Screen Map For Check and Change Motor
Phase and Encoder Polarity Parameters

Elevator Parameters

Menu Menu 2 available, if param


Drive Parameters DRIVE_TYPE = 1 (Serial Drive)

Menu

Not in RDF mode

Menu
Accept

If Lift in RDF mode


Accept

Motor Phase Polarity parameter


possible values are -1, 1
Encoder Polarity Motor Phase Polarity

Repeat Repeat
(inc) (Dec)

Accept/Menu
LWD Type
Repeat Repeat
(inc) (Dec)

Menu LWD Type parameter possible values are,


Accept -1 = clear LWD setup
DMI_ERROR MSG 0 = fixed 50% load
1 = current loop connected to Drive CPU
2 = strain gauge connected to Drive CPU
(GET_KNOWN_PARAM) 3 = current loop connected to CCG-1
4 = current loop connected to CCG-2

Motor Encoder Polarity parameter


Encoder Polarity value will blink – edit mode Encoder Polarity Value
Value (possible values are -2, -1, 0, 1, 2)
Repeat Repeat
(inc) (Dec)

DMI_ERROR MSG

Accept

(SET_KNOWN_PARAM)
KMI (BUI) Screen Map – Menu 4
– Display and Tests

Floor Markings

Menu Display and Tests Selection


Current Elevator Mode
Display and Tests
Accept
Menu

Incre Decre
Start Counter

Menu Accept
Menu

Incre Decre
Comissioning KCECPU Version Number

Incre
CPU IP Decre

Incre
Subnet Mask Decre

Incre
Gateway IP Decre

Incre
KEN Number Decre

Incre
DTS Time
Decre
Repeat Repeat
(inc) (Dec)

Incre Door Close End Signal state when doors are open
Decre for side A, Side B and side C (from right to left)
Door Close End Signal

C B A
KMI (BUI) Screen Map – Menu 4 – 1
– Elevator mode names
Normal Mode Pendant Mode

Test Drive Priority Call

Fireman’s Drive No setup Mode

Emergency Power Drive


Idle Mode

Out of Service - Car Machine/Engine Room Temperarure

Out of Service - LDG Earth Quake

Out of Service - OPT


Emergency Battery Drive

Gateway Mode Fast Recall

Pit Inspection Water Sensor Contact

Water Sensor Contact - Marine


Safe well access

Attendance Service
Fire Detection

Automatic Elevator Service


Recall Drive

Setup Mode Penthouse Visitor Service

Car Light Failed Mode


Design is based on:

Extended lwd setup with 3 points

Repeat Repeat
(inc) (Dec)

Repeat Repeat
(inc) (Dec)

Accept {lwd
setup0}

LWD setup points available L0 used to set zero


only for KDL (Serial) drive point at bottom or/
and top floor
BUI Screen Map For LWD Setup to Calibrate Drive to Empty Load

LWD Adjustment Actual value


Menu
Accept
Menu

If Drive Type is serial (KDL)

Not in RDF mode

Menu
Accept

If Lift in RDF mode


Accept

LWD_EMPTY

Accept/Menu

DMI_ERROR MSG

Accept
Menu (GET_KNOWN_PARAM)

Possible values may be -2(FIXED SCALING), -1(Clear setup) , 0(Zero


LWD_EMPTY point adjust empty car). This value will blink – edit mode
Value
Repeat Repeat
(inc) (Dec)

DMI_ERROR MSG

Accept
(SET_KNOWN_PARAM)
BUI Screen Map For LWD Setup to Calibrate Drive to Half Load

LWD Adjustment Actual value Menu


Accept
Menu

If Drive Type is serial (KDL)

Not in RDF mode


Menu
Accept

If Lift in RDF mode


Accept

LWD_EMPTY

Decre Incre
Menu

LWD_HALF
Accept

DMI_ERROR MSG
Accept
Menu (GET_KNOWN_PARAM)

Current half load value in drive (45) will blink – edit mode -(
LWD Value Browse to select the value from the valid range given by drive)
Repeat Repeat
(inc) (Dec)

DMI_ERROR MSG

Accept
(SET_KNOWN_PARAM)
BUI Screen Map For LWD Setup to Calibrate Drive to Full Load

LWD Adjustment Actual value


Menu
Accept
Menu

If Drive Type is serial (KDL)

Not in RDF mode

Menu

Accept
If Lift in RDF mode
Accept

LWD_EMPTY

Incre Decre
Menu

LWD_FULL
Accept

DMI_ERROR MSG
Accept
Menu (GET_KNOWN_PARAM)

Current full load value in drive (100) will blink – edit mode -(
Browse to select the value from the valid range given by drive)
LWD Value
Repeat Repeat
(inc) (Dec)

DMI_ERROR MSG

Accept
(SET_KNOWN_PARAM)
BUI Screen Map For Well Access Protection Mode
Activation
(Modified 20th April 15)
Display and Tests

(Detailed flow
diagrams
available with
Menu sheets – ‘lwd
setup with 3
points’, ‘Set
LWD setup Empty LWD’, ‘Set
Comissioning Comission Selection LWD Adjustment Half LWD’ and
‘Set Full LWD’ )

TOC or Pit is available, only if test


Show submenu 5-2 switch is in middle(261) or last
if Safe Well Access (263) position
is enabled and Well Access Protection Select TOC for Well Access Protection
hide submenu 5-2
if Safe well Access Repeat Repeat
is disabled (inc) (Dec)

Menu
Accept

If DOP is off
Allow Well Access Protection for
TOC (OR PIT)

Repeat Repeat
(inc) (Dec)

‘0’ will blink ‘1’ will blink

Menu If DOP is off

If lift is not in normal


Accept

mode/moving/not at
door zone

(OR) not at bottom


Well Access Protection for floor for PIT
TOC starting

Confirm Pairing

Roll Call and LON Download

Selecting Factory Default Parameters

Group
BUI Screen Map For PIN Code Configuration Mode
Activation
Display and Tests (Modified 23rd May 16)

(Detailed flow
diagrams
available with
sheets – ‘lwd
Menu setup with 3
points’, ‘Set
Empty LWD’, ‘Set
Half LWD’ and
LWD setup ‘Set Full LWD’ )
LWD Adjustment
Comissioning Comission Selection

Safe Well Access


Detailed flow diagram available with sheet
– ‘Safe Well Access’ )

Z-mini Scaffoldless installation Show 5-3 if ZMini Scaffoldless is enabled


and hide 5-3 if ZMini Scaffoldless is disabled

Based on the parameters, all


If test switch is at 262/263 the pincode enabled features
position or lift in RDF available here
PIN Code Configuration
Accept

Menu
OSS/PrC/LoC will blink to
indicate user press Accept
Incre
Decre

Otherwise key to activate the PIN code


(Min. needed is LDG call config mode
prevention(262).DOP/
RDF also allowed state)

Menu
Menu
Incre
Decre

Accept

Menu Accept

Menu/accept Lock group id number. User


can select numbers between
Inc Dec 1-64. Number will blink to
indicate user to accept lock
group id.
Accept

Press Accept Key, will stop the


number blinking. Now the system is
ready tp accept the PIN code update

Group

Blinking Stopped. This


Enables PIN Code
Configuration mode for
PRC
BUI Screen Map For Pairing Menu
(Modified 4th March 15)
Display and Tests

(Detailed flow
diagrams
available with
sheets – ‘lwd
setup with 3
points’, ‘Set
Menu Empty LWD’, ‘Set
Half LWD’ and
‘Set Full LWD’ )
LWD Adjustment LWD setup
Comissioning Comission Selection

Safe Well Access


Detailed flow diagram available with sheet
– ‘Safe Well Access’ )
Z-mini Scaffoldless installation
Show submenu 5-3 if ZMini Scaffoldless
is enabled and hide submenu 5-3 if ZMini
Scaffoldless is disabled
PIN Code Configuration

Pairing Unpaired node count Confirm Pairing


“ALL” will blink to
Accept get confirmation to
Menu activate pairing
action
Accept
Pairing Operation In Progress

Menu “In Progress” will


scroll here

Pairing operation not in progress


All nodes are
paired
Pairing Operation done Pairing Error

Menu/accept

Unpaired nodes exist

Roll Call and LON Download

Allow Roll Call and LON Download

Group
Factory Default Parameters

Set Factory Default Parameters


BUI Screen Map For Lock Group Configuration
(Modified 23rd May 16)
Display and Tests

(Detailed flow
diagrams
available with
sheets – ‘lwd
setup with 3
points’, ‘Set
Menu Empty LWD’, ‘Set
Half LWD’ and
LWD setup ‘Set Full LWD’ )
LWD Adjustment
Comissioning Comission Selection

Safe Well Access


Detailed flow diagram available with sheet
– ‘Safe Well Access’ )
Z-mini Scaffoldless installation

PIN Code Configuration

Pairing

Roll Call and LON Download

Factory Default Parameters

If test switch is at 262/263


Lock Group configuration
position or lift in RDF
Accept

Menu
Accept
Menu

Otherwise
(Min. needed is LDG call
Menu
prevention(262).DOP/
RDF also allowed state)

Menu

Lock group id number. User


Incre

can select numbers between


Decre

1-64-
Accept
Menu

Enter will blink to indicate


user to press Accept to
activate the Lock group
config mode.

Press Accept Key,


Accept

Menu/accept Screen will stop blinking


and enter text is
displayed. Now setup
for lock group starts

Press Menu/Accept
Group button. It ends the lock
group setup.
BUI Screen Map For Group Menu (Faults and
Parameters)
(Modified 13th OCT 16)
Menu 8 - Group
available, if param
GROUP_TYPE = 1
Group
Establishing Group
Connection (STIF Protocol).
Accept “In Progress” will scroll
here

Menu/Accept
(wait for 20sec)
No connection to group/ STIF connection
lost

Group Connection (STIF


Protocol) established
successfully.
Indicates that Lift
has connection to
Group Controller
Fault Code
Group Default Screen Active Fault List
Fault Active
Timeout
& Timeout

Menu Timeout
OR
!Fault Active
Incre
Indicates that Lift is under GC Fault Log Decre Fault Log Operation Selection Fault List Fault Code
Group Control (In Bank) Accept Accept Timeout

Menu Timeout
Menu
Fault Log Clearing

Incre
Decre
Group parameters( park) – Park enabled/disabled Parameter value selection
GC Parameter Set ID
Accept Accept Accept

Menu Menu Menu

Park Floor
Accept
Menu

Park Door
Accept
Menu
Incre
Decre Accept changes
Accept
Menu
No parameters available

Accept
Park and subs are visible only when feature
Accept activeted from KMC / Promanager

(Example)Next available
parameter (set id)

Visible only if Group lift


Inside subs, at any point Group (STIF)
disconnected, “Err” screen will appear. If
connected again then “Group Default
Screen” will appear
BUI Screen Map For Group Menu Parameter
Editing – Editing a parameter having an array of
values
(Modified 3rd DEC 16)

Incre
GC Fault Log Decre

Incre
Decre
Group parameters( park) – Parameter Ids
Set ID Park enabled/disabled Parameter value selection
GC Parameter
Accept Accept Accept

Menu Menu Menu

Incre
Decre Parameter value selection
Allowed lifts Param value index selection
Accept Accept
Menu
Menu
Incre Incre
Decre Decre

Accept/Menu Incre
Save the edited
Decre
Incre parameter values “End” screen informs
Accept the user that
Decre parameter index ends
here and the “Accept
key” press takes to
Park Door Parameter value selection “Parameter Ids”
Accept screen
Menu

Accept changes
Accept
Menu

Next available parameter


(set id if available)

Park and subs are visible only when feature


activeted from KMC / Promanager
BUI Screen Map For Drive Commissioning Tests
(Modified 4th FEB 14)

Comissioning
If the parameter
GROUP_TYPE is 0, then we
can navigate from Menu 5 to
Menu 9. (i.e. Menu 8 not
available)

Menu
Default Screen
Menu 9 available, if param
DRIVE_TYPE = 1 (Serial Drive)
Drive Tests
Drive Type Not
Menu
Valid OR Test Ids Menu
not available

Not in RDF mode

Accept
Menu
Lift in RDF mode
Accept
Valid Drive
(Test IDs – assumed to be max. 3 digit
Drive Tests IDs Drive Tests IDs length)
Incre

Decre

Press Incre or Decre to


Decre Browse between Test IDs
Incre
Drive Tests IDs
Test IDs:
1 – Traction Test UP
2 – Traction Test DOWN
5 – DTS Test
11 – Safety Gear Test
21 – Brake 1 Test
22 – Brake 2 Test
Accept
Menu

0 will blink to allow user to 1 will blink to get


select 1 to run the test confirmation to run the test
Run Drive Tests

Incre

Accept/Menu Decre

Test Status Already running Accept


or not ready to run
Move to select other Test Status Ready To Run - 1 will NOT
available Test ID blink - Test run command send

Accept/Menu

You might also like