Solar Tech

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 26

CONTENTS

➢ Solar PV Technology

➢ Solar Solution

➢ Case Study

© 2019 Trina Solar. All rights reserved.


Trina Solar Confidential, Public 1
New Leading Technology

210 & @210R silicon wafer N-type i-TOPCon cell mass production Working on
average efficiency up to 25.8% 863 national projects
Multi-busbar (MBB)

Innovative arrangement and Applied in China’s first batch of TüV certification of HJT products
non-destructive cutting Technology Leader Bases awarded in first half of 2021

High-density interconnection
Vertex – 19R series using G12R cells

Innovative Rectangle Wafer


Vertex 580
1,134m
1,134m 1,134m

182P - 585
182P - 545
210mm

G12R G12

2,465m
2,380m
2,278m
182mm 210mm
182mm

M10
72 cells (1/2) 66 cells (1/2) 78 cells (1/2)
580W 580W 580W

© 2019 Trina Solar. All rights reserved.


Inherit High Module power and String power features as that of 210 family
Width of module is same as 182 modules
Trina Solar Confidential, Public 3
Lower temperature coefficient

482 85℃ 85℃


436

N type P type
500 75℃ 75℃ 455
518 65℃ 65℃ 474
Power Output Power Output
536 55℃ 55℃ 493
-0.30%/℃ 554 45℃ 45℃ 512 -0.34%/℃
Temp Coefficient Temp Coefficient
572 35℃ 35℃ 531
590 25℃ 25℃ 550

• Module power is also impacted by temperature when increased, Taken 590W as an example, N type have extra 5W higher
than PERC module under the same working temperature.

• 0.04% temp coefficient advantage increase ~1% power generation

• Reliable and remarkable product for the higher temperature working environment.
Higher power generation

Grass Land Sand White Paint


Albedo =0.2 Albedo =0.4 Albedo =0.7

Power Generation
(kWh/kWp/yr)

+3.34% +4.40% +5.42%


80%(±5%) 1423 1517 1652

PERC
70%(±5%) 1377 1453 1567
Note: Stimulation result based on Pvsyst ,for whole year result.

Vertex N Module bifaciality higher than a PERC module , up to 80%±5%


Better power warranty

Lower degradation, ~3%higher energy yield!


Extra power gain during the module
life cycle 1ST Year Degradation
Annual Power Degradation(2~30 years)
N type P type
100%
99.0%
99%
98%
98.0%
30Yr More Electricity Output
Power Warranty 30Yr
Power warranty 87.4%
Maximum
Power Output
12Yr 12Yr
Product Warranty
Product warranty 84.95%

1% 2%
1 12 15 20 25 30

1st Year Degradation


1st year degradation

Product Warranty

0.4% 0.45% Main Stream P-PERC Module


Annual Degradation
Annual Degradation
~3% more power generation over 30 years
CONTENTS

➢ Solar PV Technology

➢ Solar Solution

➢ Case Study

© 2019 Trina Solar. All rights reserved.


Trina Solar Confidential, Public 9
Solar Solution

Roof Top Ground mount Floating


(Residential, (Utility) (Utility)
Commercial &
Industrial)

© 2019 Trina Solar. All rights reserved.


Trina Solar Confidential, Public 10
Roof Top
Rooftop Products
Tile-Hook

Angularity

Standing Seam NON-Penetrative


Kliplok

Hidden Buckle Type

Trapezoidal Flat-roof/ballast/tripod

Penetrative

© 2019 Trina Solar. All rights reserved.


L-Feet

Corrugated

Trina Solar Confidential, Public 11


Roof Top

© 2019 Trina Solar. All rights reserved.


Trina Solar Confidential, Public 12
Ground Mount
Fixed Ground Products

Ez-Shade Model

Ground Screw Beam


Galvanized Steel Galvanized Steel

Solar-Terrace

© 2019 Trina Solar. All rights reserved.


Trina Solar Confidential, Public 13
VANGUARD TRACKER 2P
VANGUARD

Smart-tracking Extra High power module Multi-driver


SOLAR TRACKER TYPE One row
Power Gain 3~8% 400W – 600W+ Prime wind resistance ability
STANDARD Two modules in portrait (2P)
CONFIGURATION 4 strings per row (1500 V string)

· DRIVE UNIT Linear actuator

SOLAR MODULE
Bifacial and monofacial (framed)
SUPPORTED

TRACKING RANGE 110° (±55°)

(1)
PILES PER MW ~117 piles/MW

TERRAIN ADAPTABILITY 15% N-S (2)

COMMUNICATION Wired option: RS485


WITH THE TRACKER Wireless option: Zigbee

© 2019 Trina Solar. All rights reserved.


Grid connection, string powered or
POWER SUPPLY
self-powered
Compared with Patented ball bearing + Up to 120 Module
traditional installation special bracket per Tracker NO. TRACKER PER
17
5% less installation cost Adapt to more terrain 16% fewer piles compared to OLD MW(1)

Trina Solar Confidential, Public 14


VANGUARD TRACKER 1P
VANGUARD

Smart-tracking Extra High power module Enhanced Torque Tube Design


SOLAR TRACKER TYPE One row
Power Gain 3~8% 400W – 600W+ Prime wind resistance ability
STANDARD One module in portrait (1P)
CONFIGURATION 3 strings per row (1500 V string)

DRIVE UNIT Slewing drive

SOLAR MODULE
Bifacial and monofacial (framed)
SUPPORTED

TRACKING RANGE 120° (±60°)

(1)
PILES PER MW ~242 piles/MW

TERRAIN ADAPTABILITY 20% N-S (2)

COMMUNICATION Wired option: RS485


WITH THE TRACKER Wireless option: Zigbee

© 2019 Trina Solar. All rights reserved.


Grid connection, string powered or
POWER SUPPLY
self-powered
Trina Clamp Increase natural frequency of Up to 90 Module
Save 50% installation time structure and wind resistance per Tracker NO. TRACKER PER
25
10% fewer piles compared to OLD MW(1)

Trina Solar Confidential, Public 15


16

© 2019 Trina Solar. All rights reserved.


Trina Solar Confidential, Public
Industry Background-IRR & LCOE –Bi-facial+Tracker VS. Fixed

• Tracker provide wind protection software control & safe structures


• A broader generation curves, more user friendly to grid.

Afternoon
demand peak
Fixed Structure

Tracker

© 2019 Trina Solar. All rights reserved.


Source: Myanmar's 1 GW solar tender 2019 Trina Solar Confidential, Public 17
Floater

© 2019 Trina Solar. All rights reserved.


Trina Solar Confidential, Public 18
CONTENTS

➢ Global Solar Trend

➢ Indonesia Solar Market Outlook

➢ Case Study

© 2019 Trina Solar. All rights reserved.


Trina Solar Confidential, Public 19
690W

Optimal PV solution

Vertex module
Case Study
Vertex Module BOS Cost and System Value

Project configuration
Module 182-620W 210-690W

DC capacity (MWdc) 100 MWp


Location : West, Indonesia
Inverter:Huawei-330KTL,1500V DC/AC ratio 1.3

Assumed lowest temp: 20℃ Module power(W) 620 690

2,465 2,384
Dimension(mm)
1,134 1,303

Module in series 26 30

String Nb. 6,204 4,831

String power(W) 16,120 20,700

Strings/Rack 2 2

Rack units 3,102 2,416


Vertex Module BOS Cost and System Value

1 x Huawei-330KTL Typical array Equipment comparison

620W Main Equipment Bill 690W Main Equipment Bill


Item
Description Quantity Unit Description Quantity Unit

PV module 182-620W 624 pcs 210-690W 570 pcs

Inverter Huawei-330KTL 1 set Huawei-330KTL 1 set

MC4 connector Male and female 24 pair Male and female 19 pair

Cable DC XLPE/1.8kVdc Cable DC XLPE/1.8kVdc


PV XLPE cable Cu 1x6mm²
5.76 km
Cu 1x6mm²
4.56 km
Vertex Module BOS Cost and System Value

Mounting structure configuration

2P Fixed tilt mounting structure Details Gap

M o d u l e p o we r 620 690

S t r i n gs / R a c k 2 2

A r ray t i l t 15° 15°

Po we r / R a c k ( W ) 32,240 41,400 + 28%

Rack Units. 3,102 2,416 - 22%


Vertex Module BOS Cost and System Value

690W modules’ high string power feature leads to BOS


saving on cable, installation, piles and drilling
BoS Comparison
100MWp key figures 140%
128%

120%
Module type 182-620W 210-690W

100% 93%
String power(W) 16,120 20,700 90%

77% 78%
80%
Module Nb. 161,304 144,930 620W (182)

60% 690W (210)


String Nb. 6,204 4,801
40%
XLPE-6mm²cable(km) 1,488 1,159
20%
Pile Nb. 62,040 57,984
0%
String Power Module Nb. String Nb. DC Cable Pile Nb.
Vertex Module BOS Cost and System Value
BOS saving

*BOS cost and savings Unit:$/W 0.55 cUSD$/W


Item/Module type 620W 690W

Module mounting 0.0091 0.0090 *BOS $/W 182-620W VS 690W


Inverter 0.0201 0.0201
0.12
MC4 connector 0.0008 0.0006 0.108
0.1025
PV XLPE 6 mm² cable 0.0068 0.0053 0.1
Rack with piles 0.0712 0.0675
0.08
*BOS 0.108 0.1025

*BOS gap BL -0.0055 $/W


0.06

0.04

0.02

0
182-620W 210-690W

*BOS:only shows items on which different modules could make difference


26

© 2019 Trina Solar. All rights reserved.


Trina Solar Confidential, Public

You might also like