What is the ATEX Directive? Rechargeable battery compatible component P4* Series
Issued in July 2003 as part of the CE Marking Compliance Directive by the EU (European Community) The development of rechargeable batteries and next-generation batteries have progressed, and the explosion-proof components have
Directive 94/9/EC. Electrical components and non-electrical components (cylinders that cause friction, also met the component requirements with improved dry environmental performance. These products provide production stability in the
impact, or wear) intended for use in explosive atmospheres when manufactured, sold, distributed, or installed manufacturing process, meeting the needs of rechargeable battery manufacturing, from electrode production to packaging.
* In this guide, "●" is indicated for models that are compatible with rechargeable batteries so that users can select ATEX Directive-compliant and rechargeable battery-compatible models.
in EC member countries are subject to regulations. The current ATEX command number is 2014/34/EU.
Limited copper Limited zinc Limited nickel- Limited zinc Limited electrolytic
material material based material plating nickel plating
combustible liquid
Dry environment
Long service life even in -70°C dew point environments
Ultra-dry environment compatible grease is used.
Retains the smooth operation of the sliding part for long periods, even in dry
environments.
Components Dangerous zone Dangerous zone
Explanation of Dangerous Zones
Category (Gas) (Particulates)
Zones where explosive atmospheres are present continuously or for long periods
1 Zone 0 Zone 20
(more than 1000 hours/year. *1)
Stable operation
Contributing to a system that never stops
Zones where explosive atmospheres may be generated during normal operation of the plant, etc. Uses a special grease that supports low dew points and high frequency. Contributes to stable operation of equipment.
2 Zone 1 Zone 21
(10 to 1000 hours/year. *1)
Change in tact time Change in starting pressure
Zones where explosive atmospheres are not likely to be generated during normal operation of a
3 Zone 2 Zone 22 Operating Starting
plant or the like and are only present for a short time even if generated (1 to 10 hours/year. *1) time pressure
To expand the range of components required for equipment configuration, CKD offers a large lineup of ATEX-certified and non-ATEX-certified components.
Operational cycle Operational cycle
Components subject to the ATEX Directive Handling of components not subject to the ATEX Directive
Components are classified into categories such as electrical and non-electrical Products that meet the following conditions are
products, and certification and self-declaration are conducted by certification bodies. excluded from EU Directive 2014/34/EU and can
Counters dust & dust generation
Long service life even in dusty environments
be used in explosive atmospheres without meeting
Component category Electrical Component Non-electrical components Strong dust-proof mechanisms such as scraper/rod packing are used.
special requirements.
(Zone) (solenoid valve, flow rate sensor, etc.) (cylinder, air operated valve, etc.) Suppresses dust entry into the cylinder.
Category 1 Certification by Certification by Equipment that does not have a potential ignition source.
(Zone 0/20) Certification Body Certification Body Components that do not have the autonomous Suppresses dust generation of metal wear powder
Category 2 Certification by Self-declaration by functions required for the safety function of the Equipped with a local exhaust function (vacuum treatment port). Prevents
(Zone 1/21) Certification Body CKD ATEX Component or protection system. contamination to the electrodes or cell by not leaking the metal wear powder outside.
Category 3 Self-declaration by Self-declaration by
(Zone 2/22) CKD CKD
2 3
Pneumatic cylinders Pneumatic cylinders
Zone Zone
Battery compatible
Battery compatible
Rechargeable
Rechargeable
Product name/model No. Explosion-proof grade Gas Particulates Product name/model No. Explosion-proof grade Gas Particulates
0 1 2 20 21 22 0 1 2 20 21 22
*Indicates the Zone that can be installed when the cylinder does not have a switch. The Zone that can be utilized when the cylinder is equipped with a switch.
4 5
Directional control valve Refining and pressure adjusting components
Zone Zone
Battery compatible
Battery compatible
Rechargeable
Rechargeable
Product name/model No. Explosion-proof grade Gas Particulates Product name/model No. Explosion-proof grade Gas Particulates
0 1 2 20 21 22 0 1 2 20 21 22
Filter/regulator
Not applicable
W**00-W
Pilot operated 3, 5-port
solenoid valve II2G Ex ib IICT4 Gb Filter/regulator Flame-
4GD/E EA resistant Series Not applicable
W**00-G4
Filter/regulator
Not applicable
WB500
Zener barrier (1ch) II(1)GD, I(M1) [Ex ia Ga] IIC, Compact air filter
Not applicable
Z728 [Ex ia Da] IIIC, [Ex ia Ma] I A1019
Inline filter
Not applicable
FSL
Regulator
Not applicable
Quick valve R**00-W
Not applicable
2QV,3QV
* Regulator/flame-resistant
Series Not applicable
R*000-G4
Regulator oil-prohibition
Series Not applicable
RN*000-W
Mechanical valve Regulator medium pressure
Not applicable
MS,MM,MAVL Series Not applicable
RM*000-W
Battery compatible
Battery compatible
Rechargeable
Rechargeable
Product name/model No. Explosion-proof grade Gas Particulates Product name/model No. Explosion-proof grade Gas Particulates
0 1 2 20 21 22 0 1 2 20 21 22
Clean regulator Speed controller
Not applicable Not applicable
RC2000 SC3W
Speed controller, universal
Clean regulator Not applicable
Not applicable SC3U
2619
Speed Controller Direct Port
Not applicable
Compact regulator Elbow SC3R
Not applicable
B2019 Speed Controller Stainless
Steel Corrosion Resistance Not applicable
Large bore size regulator SC3P
Not applicable
2215
Speed controller Line type
Not applicable
Compact reverse regulator SCL2, SCD2
Not applicable
2419 Speed controller, large bore
Not applicable
size type SC
Large bore size reverse regulator
Not applicable Miniature speed controller
2415 Not applicable
SC-M
Dial regulator Miniature meter-in meter-out
Not applicable Not applicable
2302/2303/2304 speed controller SCD
Speed controller, medium
Relief valve Not applicable
Not applicable bore size SC1
B + 6061
Speed controller with
Not applicable
Lubricator adjusting dial DSC
Not applicable
L*000-W Needle valve with adjusting
Not applicable
dial DVL
Compact lubricator
Not applicable Quick exhaust valve with
A + 3019 Not applicable
push-in fitting QEL
Large bore size lubricator Quick exhaust valve QEV2 Not applicable
Not applicable
3003E,3004E,3005E
Shuttle valve SHV2 Not applicable
Residual pressure exhaust valve Check valve CHV2 Not applicable
Not applicable
V*0*0-W
Block valve FPV Not applicable
Drain discharger Fitting GW Not applicable
Not applicable
DT3000-W,DT4000-W
Fitting
Not applicable
Drain discharger Stainless steel ZW
Not applicable
5100-4C Fitting
Not applicable
Mini GWJ
Low-profile pressure gauge
Not applicable Fitting
G401-W Not applicable
Stainless steel ZSP
Miniature pressure gauge Miniature fitting F Not applicable
Not applicable
G29D,G39D Tightening fitting MJ, JL Not applicable
Pressure gauge with safety marker Tightening fitting Stainless
Not applicable Not applicable
G40D steel ZJ
Rotary fitting
Pressure gauge with limit marker Not applicable
Not applicable RJF
G45D
Fiber tube/dedicated fitting
Pressure gauge with limit marker UP, PTN2, PTNL2, EH, PG, Not applicable
Not applicable CG, RG
G41D
Tube
General-use pressure gauge Not applicable
Not applicable F, FH, NU, U, KX, SR, AZ
G49D,G59D
Silencer Small bore size/resin
Not applicable
Pressure gauge for panel mounting body SL, SLW
Not applicable
G53D Miniature Silencer
Not applicable
SLM
Vacuum pressure gauge with limit marker
Not applicable Silencer SL Not applicable
VG41D
Metering valve with silencer
Moisture indicator Not applicable
Not applicable SMW2
6119-2C
Metering valve with silencer
Not applicable
Drain separator FMS,SMW
Not applicable
FX Nozzle BN Not applicable
Desiccant air dryers
Manual air dryer Not applicable
4001, 4002
8 9
Related products Related catalog
Zone
ATEX Directive compliant 4GD/E EA Series CC-1458A
Battery compatible
Rechargeable
Product name/model No. Explosion-proof grade Gas Particulates
0 1 2 20 21 22
Explosion-proof performance II 2G Ex ib IIC T4 Gb
Intrinsic safety explosion-proof
Compact flow
rate sensor
(RAPIFLOW)® Explosion-proof Components Guide CC-1494A
Flow rate
FSM3-EX II 3G Ex ec IIC T6 Gc
sensor
Environment- Intrinsic safety explosion-proof/Pressure and explosion-proof components are listed.
resistant
specifications Usable locations: Zones 1, 2
Dry environment
Long service life even in -70°C dew point environments
Stable operation
Contributing to a system that never stops
10 11
2023.7