DALMIA CEMENT (BHARAT) LTD

ARIYALUR
Raw Mill - False Air Report
Date 14.07.2021

Description O2 % False Air %

PH fan outlet
Mill I/L 7
PH fan O/L to Mill Inlet
Mill outlet 8.1 7.86%
Mill Fan I/L
Fan outlet 8.8 5.43%
Across the system 12.86%
BH O/L 10.1
Across BH 10.66%

14.07.2021
Sl.
Duct dia. Duct area Temp.
Location
No.
m m2 oC
Cement mill
1 2.2 3.8 240
booster fan inlet
2 Recirculationair 4 12.57 80.5

3 Fan Inlet 4.5 15.9 72

Mill feed 244 TPH


Fan Speed 873 RPM
Fan Power 2340 KW
SPRS Rec. 273 KW
DALMIA CEMENT (BHARAT) LTD

ARIYALUR
Coal Mill - False Air Report
Date 14.07.2021

False Air
Description O2 %
%

Coal Mill Cyclones I/L 5.5


1.90%
Coal Mill Cyclones O/L 5.8
Across Cyclone 1.90%

Mill I/L 6.8


8.50%
Bag house inlet 8
7.70%
Bag house fan inlet 9
2.50%
Bag house fan Outlet 9.3

Across the Mill and Bag house 17.60%


Total 19.50%

CEMENT MILL FALSE AIR


Avg.
Static pr. dynamic Density Velocity
pressure
mm WG mm WG Kg/Nm3 Kg/m3 m/s
2.59
-12 1.293 0.68 11.82
6.7
4.34
-15 1.293 0.98 16.42
19
5
-680 1.293 0.94 17.64
20.78
650750 Inlet
Falseair 736741 outlet
11.67 Falseair%
DALMIA CEMENT (BHARAT) LTD

ARIYALUR
Preheater - False Air Report
Date 13.07.2021

False Air
Description O2 %
%

V Cyclone O/L 1.3


6.75%
PH fan I/L 2.63
1.47%
PH fan O/L 2.9
Total

Volume

m3/hr Kg/hr Nm3/hr


161756 109795 84915

742963 731625 565835

1010002 952606 736741