NUMBER E07-X01

REV. NO. 2
ENGINEERING STANDARD DATE MAR 2004
PAGE 1 OF 3

Stand-By Diesel Generators, 480 and 4160 V


Data Sheet

This document is issued by Engineering Standards Section, SABIC Engineering and Project Management, Kingdom of Saudi Arabia.
The information contained in this document is the confidential property of SABIC. It can not be disclosed, copied or used for any purpose
without prior approval from SABIC. If you are not authorized to possess this document, please destroy it immediately.
NUMBER E07-X01
Stand-By Diesel Generators, REV. NO. 2
480 and 4160 V Data Sheet DATE MAR 2004
ENGINEERING STANDARD PAGE 2 OF 3

1. Scope
These data sheets shall be used in conjunction with SES E07-S01.

Project : _________________ Job No.: ____________ Item No. : ___________ Manufacturer Ref. No. : ________
Affiliate/Plant location : ______ Unit Tag: ___________ No. of units: ___________ Vendor : ____________________

GENERAL

Location Site conditions


{ Indoors { Outdoors Relative humidity % : max_______ min _______
Area classification Altitude above sea level __________m
Auto ign temp ___°C UBC seismic zone _________ Temperature °C max ________ min _______
Corrosive atmosphere { Yes { No

GENERATOR DATA MODULES

Volts_________ Phase_________ Hertz__________ { Fuel system


Power, kW _________ KVA _________ { Exhaust system (See SES G10-S01)
Synchronous rpm_______ Service factor __________ { Starting system : { Electric { Air
Insulation class_________ { Diesel fuel tank (See SES G10-S01)
Temperature rise _____ °C above _____ °C by _____ { Cooling module
Winding { Wye { Delta { Governor system
{ Excitation system Volts ______ Watts ______

ELECTRIC SYSTEM CONDITIONS ENCLOSURE

{ Short circuit MVA at gen. bus { Not required


{ Method of system grounding { Ventilated, weather proof
{ Ground fault max amperes { Sound attenuated
{ Other { Space heaters

MISCELLANEOUS INSPECTION AND TESTING

{ Max sound pressure level, dBA ______ { Factory inspection by SABIC


{ Oscillator - demodulator { Testing to be witnessed by SABIC
{ Required { Standard production tests required
{ Not required { Special testing required as below :
{ Open circuit saturation
Vibration Monitor { Generator short circuit saturation
{ Required { _____________________________________
{ Not required { _____________________________________

WINDING TEMPERATURE DEVICES BEARING TEMPERATURE DEVICES

{ RTD Type: { RTD Type:


Resistance material _____________________ Resistance material _____________________
Ohms ________________________________ Ohms ________________________________
No./Phase ____________________________ No./Phase ____________________________
{ Wiring: { 3-wire { 2-wire { Wiring: { 3-wire { 2-wire
{ Terminated in separate NEMA 4X term. box { Terminated in separate NEMA 4X term. box
{ Max stator winding temperature, °C: { Max stator winding temperature, °C:
{ Alarm { Shutdown { Alarm { Shutdown
NUMBER E07-X01
Stand-By Diesel Generators, REV. NO. 2
480 and 4160 V Data Sheet DATE MAR 2004
ENGINEERING STANDARD
PAGE 3 OF 3

GENERATOR CONTROL PANEL MAIN JUNCTION BOX

{ NEMA 1 cabinet { Main gen. leads


{ Wiring entrance: Conductor size: __________________________
{ Automatic transfer and paralleling Type: __________________________________
{ Completely assembled with devices as checked Insulation:_______________________________
DEVICES MOUNTED ON FRONT OF PANEL, IF Number per phase: _______________________
FURNISHED, LABELED AS INDICATED: Enter from: { above { below
{ Generator start-stop switch { Current transformers for protective relaying
{ Generator manual-automatic switch Accuracy class ___________________________
{ Generator emergency-stop switch Mounted by _____________________________
{ Exciter field on-off switch Quantity _______ Ratio______
{ Pilot Lights: { Run { Stop { Ready { Current transformers for neutral ground
{ Ammeter fault protection
0- ___ A scale, generator amperes Accuracy class ___________________________
{ Voltmeter Mounted by _____________________________
0- ___ A scale, generator voltage Quantity _______ Ratio______
{ Power factor meter, _____ scale { Current transformers for metering
{ Ammeter Accuracy class ___________________________
0- ___ A dc scale, exciter field amperes Mounted by _____________________________
{ Manual voltage adjusting rheostat, exciter field Quantity _______ Ratio______
{ Elasped time meter, run time { Current transformers for excitation control
{ Alarm panel Accuracy class ___________________________
{ Automatic voltage regulator Mounted by _____________________________
Quantity _______ Ratio______
RESISTIVE LOAD BANK { Potential transformers
{ Required { Not required Accuracy class___________________________
{ Permanent { Portable Mounted by _____________________________
Ratings: Quantity _______ Ratio______
kW ________ Fuses required___________________________
Volts _______ 3Ph, 60Hz { Space heaters
Amps/phase ________ Volts_____ Phase_____ Hertz_____
Control panel: { Space for stress cones
Indoor : { Rack mount { Wall mount { Surge capacitors
{ Surge arresters

MOTOR CONTROL CENTER

{ 600 V { Required { Not required { Auto transfer switch


{ 4160 V { Required { Not required { Required { Not required