01 & 11-12-2023 C7 Turbine Exhaust Radiation Shield - PT

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 13

Lab Code No.

: Page 1 of 7
Report No. :

Worksheet for Dye Penetrant Examination

Information Supplied by Client

Client : CLP Power Hong Kong Ltd.


Client Address : GED Black Point Power Station, Yung Long Road, Lung Kwu Tan,
Tuen Mun, N.T., Hong Kong
Project : Provision of Specialized Service - NDT
Location of test : Black Point Power Station Unit: C7 Plant: Turbine
Component description : Exhaust Radiation Shield
Welding process : M.M.A.W
Component Material : Alloy Steel
Acceptance Standard : All indications to be reported
New Engineering Contract No. :
W.O. Number :

Laboratory Information

Date tested : 01 & 11/12/2023


Inspection procedure MI-17.5.1-N019
Surface condition : As Smooth, Dry and Clean
Viewing condition : ( >1000Lux) Artificial Light
Pre-cleaning : Cleaning the surface with clean cloths & rag

Equipment ID. & Consumable Use :-


- Penetrant : SHERWIN DP-50
- Remover : SHERWIN DR-60
- Developer : SHERWIN D-100

Remarks : 1. All test results are as at time of testing.


2. All test locations are as directed by the client.
3. See the attached sketch for test locations.

Results Summary:
Parts with deviation :
Parts with no deviation :
Remarks : --

NT-R-78 (25/10/2008) P.1


Lab. Code No. : 0 Page 2 of 7
Report No. : 0

Worksheet for Dye Penetrant Examination


Test Results

Description of Test Item : C7 - Turbine Exhaust Radiation Shield

Item Tested Location Tested Indication No. Remarks


Shield No.8 J1 to J3 -- No Recordable Indication
(100% Weld Tested)
Shield No.9 J1 & J2 -- No Recordable Indication
(100% Weld Tested)
J3 #1 65mm in length of crack
#2 80mm in length of crack
Shield No.10 J1 & J2 -- No Recordable Indication
(100% Weld Tested)
J3 #1 50mm in length of crack
#2 65mm in length of crack
Shield No.11 J1 & J2 -- No Recordable Indication
(100% Weld Tested)
J3 #1 90mm in length of crack
Shield No.12 J1 & J2 -- No Recordable Indication
(100% Weld Tested)
J3 #1 20mm in length of crack
#2 25mm in length of crack
Shield No.13 J1 to J3 -- No Recordable Indication
(100% Weld Tested)
Shield No.14 J1 to J3 -- No Recordable Indication
(100% Weld Tested)
Shield No.15 J1 to J3 -- No Recordable Indication
(100% Weld Tested)
Shield No.16 J1 to J3 -- No Recordable Indication
(100% Weld Tested)
Shield No.17 J1 to J3 -- No Recordable Indication
(100% Weld Tested)
Shield No.18 J1 to J3 -- No Recordable Indication
(100% Weld Tested)
Shield No.19 J1 to J3 -- No Recordable Indication
(100% Weld Tested)
Shield No.20 J1 to J3 -- No Recordable Indication
(100% Weld Tested)
Shield No.21 J1 to J3 -- No Recordable Indication
(100% Weld Tested)
Shield No.22 J1 to J3 -- No Recordable Indication
(100% Weld Tested)
Shield No.23 J1 & J2 -- No Recordable Indication
(100% Weld Tested)
J3 #1 50mm in length of crack

01 &
Tested by : C.W.Kung Qualification : ASNT-SNT-TC-1A-Level II Date : 11/12/2023

Authorized by : Position : Manager - NDT Welding Date :


BABU, Vinodh Kumar ASNT-PT-Level 3
NT-R-78 (25/10/2008) P.2
Lab. Code No. : 0 Page 3 of 7
Report No. : 0

Worksheet for Dye Penetrant Examination


Test Results

Description of Test Item : C7 - Turbine Exhaust Radiation Shield

Item Tested Location Tested Indication No. Remarks


Shield No.24 J1 & J2 -- No Recordable Indication
(100% Weld Tested)
J3 #1 50mm in length of crack

Shield No.9 #1 & #2 -- No Recordable Indication (After Repaired)


Shield No.10 #1 & #2 -- No Recordable Indication (After Repaired)
Shield No.11 #1 -- No Recordable Indication (After Repaired)
Shield No.12 #1 & #2 -- No Recordable Indication (After Repaired)
Shield No.23 #1 -- No Recordable Indication (After Repaired)
Shield No.24 #1 -- No Recordable Indication (After Repaired)
**End**

01 &
Tested by : C.W.Kung Qualification : ASNT-SNT-TC-1A-Level II Date : 11/12/2023

Authorized by : Position : Manager - NDT Welding Date :


BABU, Vinodh Kumar ASNT-PT-Level 3
NT-R-78 (25/10/2008) P.2
Lab Code No. : 0 Page 4 of 7
Report No. : 0

Worksheet for Dye Penetrant Examination

C7 - Turbine Exhaust Radiation Shield

J3

J3 J2
No.9 #1 &
J2 #2

No.24 #1
No.10 #1
& #2
No.23 #1
No.11 #1

No.12 #1
& #2
VIEW TO TURBINE
J1 J1

Test Location for Exhaust Radiation Shield No.8 to No.24 (J1 to J3)
Indication Location for Exhaust Radiation Shield No.9 to 12 & 23, 24 (J3)

Remark: This sketch is not in scale.


Indication location Tested Area
NT-R-78 (25/10/2008) P.3
Lab Code No. : 0 Page 5 of 7
Report No. : 0

Worksheet for Dye Penetrant Examination

C7 - Turbine Exhaust Radiation Shield

CASIO : CIMG8260.JPG CASIO : CIMG8261.JPG


Indication location for Radiation No.9 #1, 65mm in length of crack

CASIO : CIMG8262.JPG CASIO : CIMG8263.JPG


#2, 80mm in length of crack Indication location for Radiation No.10

CASIO : CIMG8264.JPG CASIO : CIMG8265.JPG


#1, 50mm in length of crack #2, 65mm in length of crack

Remark: This sketch is not in scale.


Indication Location
NT-R-78 (25/10/2008) P.3
Lab Code No. : 0 Page 6 of 7
Report No. : 0

Worksheet for Dye Penetrant Examination

C7 - Turbine Exhaust Radiation Shield

CASIO : CIMG8266.JPG CASIO : CIMG8267.JPG


Indication location for Radiation No.11 Indication location for Radiation No.12
#1, 90mm in length of crack

CASIO : CIMG8268.JPG CASIO : CIMG8269.JPG


#1, 20mm in length of crack #2, 25mm in length of crack

Remark: This sketch is not in scale.


Indication Location
NT-R-78 (25/10/2008) P.3
Lab Code No. : 0 Page 7 of 7
Report No. : 0

Worksheet for Dye Penetrant Examination

C7 - Turbine Exhaust Radiation Shield

CASIO : CIMG8270.JPG CASIO : CIMG8271.JPG


Indication location for Radiation No.23 #1, 50mm in length of crack

CASIO : CIMG8272.JPG CASIO : CIMG8273.JPG


Indication location for Radiation No.24 #1, 50mm in length of crack

Remark: This sketch is not in scale.


Indication Location
NT-R-78 (25/10/2008) P.3

You might also like