CYCLE TIME
Eng. Full No load PC200 2.9—3.7 Max. 4.7
Boom Raise
A mode Fully extend PC210 3.0—3.8 Max. 4.8
PC200 2.4—3.0 Max. 3.5
Arm-OUT
PC210 2.5—3.1 Max. 3.6
A mode
PC200 3.2—3.8 Max. 4.5
Eng. Full PC210 3.2—3.8 Max. 4.5
Arm-IN A mode PC200 3.3—3.9 Max. 4.6
E mode
(Boom horizontal position) PC210 3.4—4.0 Max. 4.7
PC200 5.8—7.0 Max. 7.4
L mode
PC210 5.8—7.0 Max. 7.4
Boom & Arm PC200 2.3—2.9 Max. 3.3
Bucket Curl
horizontal PC210 2.3—2.9 Max. 3.3
L.H.
Swing 5 Turns Sec. 21.7—26.7 Max. 30.0
R.H.
L.H.
Hi 26.6—29.4 26.6—31.4
R.H.
PC200,210—7 L.H.
Mid 33.7—41.3 33.7—45.3
Travel 5 Turns Eng. Full R.H.
A mode L.H.
Lo 46.2—56.4 46.2—60.4
R.H.
L.H.
Hi 29.0—32.0 29.0—34.0
R.H.
PC200LC,220LC—7 L.H.
Mid 36.7—44.9 36.7—48.9
Travel 5 Turns R.H.
L.H.
Lo 50.3—61.5 50.3—65.5
R.H.
09-03 1/3
PC200 (LC)-7#200001~ PMEH103000
Pm-CLINIC SERVICE
PC210 (LC)-7#40001~
STD.: Standard Value
HYD. PRESSURE ( ) : Reference Value PMS.: Permissible Value
ITEM Condition Unit STD. PMS. Result Sat Us
Control cirguit 3.04—3.43 2.84—3.43
pressure Arm OUT relief {31.0—35.0} {29.0—35.0}
Rear pump POWER UP OFF 33.8—35.8 33.3—36.8
pressure {345—365} {340—375}
Front pump 33.8—35.8 33.3—36.8
pressure {345—365} {340—375}
Rear pump 33.8—35.8 33.3—36.8
pressure {345—365} {340—375}
Front pump 33.8—35.8 33.3—36.8
LS pressure A mode {345—365} {340—375}
Arm OUT relief
Main relief
09-03 2/3
PC200 (LC)-7#200001~ PMEH103000
Pm-CLINIC SERVICE
PC210 (LC)-7#40001~
STD.: Standard Value
HYD. PRESSURE ( ) : Reference Value PMS.: Permissible Value
ITEM Condition Unit STD. PMS. Result Sat Us
★ Connection to be changed to hoses e and r , and gauge to be replaced with one with 60K capacity.
A mode (3.33) —
Low {(34)} —
A mode (0.29) —
Full {(3.0)] —
PC/EPC
E mode (1.37) —
PC—EPC valve
Full {(14.0)} —
L mode (2.06) —
All levers in NEUTRAL
Full {(21.0)} —
AUTO-DECEL. OFF
B mode (1.57) —
POWER UP ON
Full {(16.0)} —
Front pump 2.94—4.90 2.94—4.90
pressure {30.0—50.0} {30.0—50.0}
Rear pump 2.94—4.90 2.94—4.90
pressure {30.0—50.0} {30.0—50.0}
(2.94) (2.94)
LS—EPC valve
A mode {(30.0)} {(30.0)}
Front pump Full MPa 33.8—35.8 33.3—36.8
pressure {kg/cm2} (345—365} {340—375}
Rear pump 33.8—35.8 33.3—36.8
pressure (345—365} {340—375}
(0) (0)
LS—EPC valve Arm OUT relief
LS/EPC
{(0)} {(0)}
AUTO-DECEL. OFF
Front pump 36.3—38.2 36.3—39.2
POWER UP OFF
pressure {370—390} {370—400}
Rear pump 36.3—38.2 36.3—39.2
pressure {370—390} {370—400}
(0) (0)
LS—EPC valve
L mode {(0)} {(0)}
Front pump Full 36.3—38.2 36.3—39.2
pressure {370—390} {370—400}
Arm IN relief
Rear pump 36.3—38.2 36.3—39.2
AUTO-DECEL. OFF
pressure {370—390} {370—400}
POWER UP OFF
(0) (0)
LS—EPC valve
{(0)} {(0)}
★ The "L" mode is on the multi-monitor specification machine only
HYD. OIL
ITEM Condition Unit STD. PMS. Result Sat Us
Dip the oil thermometer sensor into
Hyd. Oil temp. : 45—55
the middle of the hyd. oil tank.
HYD. DRIFT
Entire work equipment no load Rated load
mm Max. 600 Max. 900
specific position Eng. Stopped
NOTE: Write-down any phenomena or information, you found by your five sences during today's inspection.