Professional Documents
Culture Documents
Single Col - Footing
Single Col - Footing
Input Calculation
Allowable Bearing Capacity = 3.0 ksf Pnet = 3.3 ksf
Column Load = 52 kip Effective "d"= 8.0 in
Self Weight =5 kip Check for Punching Shear Check for Moment
Total load ### = 52 kip Vp = 45 kip Moment (Long direction) =
Area required = 17 sft vp = 78 psi d reqd.= 4 in
Footing length = 4.00 ft Allowable v = 110 psi
Footing Width = 4.00 ft Design Ok Design Ok
Area Provided = 16 sft Increase Size Check for Shear Moment(Short direction) =
Column length = 10 in Vc = 2.98 kip/ft As (Long direction) =
Column Width = 10 in vc = 31 psi As (Short direction) =
Thickness = 11.00 in
Bar size = 12 mm Allowable v = 60 psi Minimum Steel (As) =
f'c = 3 ksi n= 9 r = 18 k= 0.343 Design Ok
fy = 60 ksi j= 0.886 R= 205
RESULT
Length = 4.0 ft Width= 4.0 ft Thickness = 11 in As (Long) = 0.3 sq. in As (Short)
Bar area= 0.175 T12@ 7.95inchc/c (L.W) T12@ 7.95inchc/c (S.W)
11 "
4.00 ft
0.3 sq. in 0.3 sq. in
Design Ok
hort direction) = 4 k-ft /ft
direction) = 0.23 sq.in/ft
direction) = 0.23 sq.in/ft
8.0 "
sq. in