Download as pdf
Download as pdf
You are on page 1of 8
Technical Bulletin TB 720 Page 108 eo BARBER-ROTORK MODEL"HQ" Hydraulic Self Contained Actuation Systems For Quarter Turn Valves NO FLOW LINE POWER REQUIRED NO COMPRESSED AIR NO NATURAL GAS NO ELECTRICITY = NO NITROGEN abe Psousrces un Technica! Bullet TB 720 Page 2of Barber-Rotork Model “HQSP” & “HQH” Actuators Barber-Rotork Model “HQ” hydraulic sell-contained, soring return actuation systems operate without the noed of any external source of actuation energy. These systems operate unattended outdoors, in all climatic environments. __ pres weamrevercie A To | 4 ccceeemoas | a cee meus The model “HQSP” actuator and control 8 dip | ee system is supplied complete with a low pressure hydraulic “Presco Pump TAP pSggSgreee Module’. The maximum working A tL [Pee pressure of the actuator and controls is M7 180 P'S.I. with a maximum spring break Figure 2, General Arrangement For Mode "HOH" Actuator ‘The model *HQH" actuator and control system is supplied complete with a high pressure hydraulic “Presco Pump Module". The maximum working pressure of the actuator is 3000 P.S.I. with a maximum spring break torque available of 308,720 in. Io. ‘The high pressure hydraulic “Presco Pump Modula” also provides a 180 PSLL maximum control pressure output, as well as 9000 P.S.l. maximum working pressure actuator output. They requir intervention oniyto manual ssounpine actuator the evant ofa signalled nyu fd fleas Icthe reser: Fgute 1 & Figure 2 sow Iwo typical CP systems followed by general and detailed information about each sym, Figure 1, General Arrangement For Model "HOSP" Actuator torque of 8653 in. Ib. Lt = nn Babe ivsmese 13 720 Operating Instructions of “HQSP” Before Operating Ensure proper installation has been carried out in accordance with installation instruction form. Opening Valve (fall close operation) The latching trip valve toggle (located on “Presco-Pump. Module") must be in the "LATCHED” or the “ARMED” position before the actuator / valve can be pumped open. Operating the pump will pressurize the hydraulic circuit {an in turn open the valve. When the actuator is, completely open against the end position stop, additional pumping will force the hydraulic fluio past a pressure limiting valve back to the reservoir thus protecting the actuator against excessive pressure. Shifting of the latching trip valve from the manually *LATCHED" position to the "ARMED" position is controlled by the status of the control / rigging ceviee (high / low line sensing pilot, solenoid trip etc.) See operating instructions for each dovice as required. When the latching trip vaive has shifted to the "ARMED" position, it will remain in that position until the pilot or other S-way trip control valve signals a shut-in or the latching trip valve toggle is manually pushed into the “TRIPPED” position, TRIPPED Latching Trip Valve Positions Tripping Control of Actuators Most applications require the spring to operate the actuator when a pressure source being monitored deviates froma desired range. ‘A pressure responsive 3-way valve called a “Presco-Pilot” (see Presco-Pilot bulletin) is most commonly used to connect the control pressure te the latching trip valve, When the monitored pressure deviates from the range between set points, the “Presco-Pilot” blacks the control pressure and allows the hydraulic fluid from the signal port of the latching trip valve to flow to the reservoir, When this ocours, the latching trip valve opens and allows the hydraulic fluid in the cylinder to flow te the reservcir and the actuator spring shifts the quarter turn valve. (Ee 4] LATCHED Technical Buetin Page 3018 & “HQH” Systems After the actuator J valve has bean pumped open, the field technician should make certain that the latehing trip valve is in the “ARMED” position betore leaving the site. Closing the Valves The actuator / valve will emai in the open position as long as the hydraulic fluid in the actuator cylinder is prevented irom escaping losing of the actuator / valve is intiated by opening the latching trip valve, The latching trip valve can be shifted to ‘open “TRIPPED” position from the “ARMED” position by: 2, Manually pushing the toggle lever to override the spring thus allowing the hydraulic fluid in the actuator oylinder to flow to the reservoir b. The trip vaive will automatically shift to the “TRIPPED” position and close the actuator / valve whenever the conta / tripping device allows the hydraulie fluid to flow from the latching trip valve “SIG” port to the reservoir. ‘The actuator cannot close the valve unless the toggle lever of trip valve is unlatched and in the “ARMED position. ARMED Other Hydraulic Controls electric controls are required, a solenoid operated 3 way valve can be mounted on the actuator and all hydraulic connections will be completed in our facilities in which case, only electrical connections wil be required at time of installation, ‘The 3-way solenoid valve can be connected to trip the actuator by either application or removal of control voltage. Flow control valves or quick exhaust valves can be added to control opening and closing speeds of the actuator. Additional trip control valves that have independent Pneumatic or hydraulic signals can be added to the standard circuit, ‘Teenrical Bulatn 73.720, Poge Hydraulic Schematic of Model “HQSP” Manually Pumped-Spring Return Valve Actuator System with Pressure Monitoring Pilot Trip Control 408 Babe Fecems0 LEGEND. Cylinder Pressure Suction | Ref --.--<--

You might also like