Bracket and Anchor Design: at Typical Location-Basement 3 For Load ASD Combination Bracket & Anchor Ultimate Condition
Bracket and Anchor Design: at Typical Location-Basement 3 For Load ASD Combination Bracket & Anchor Ultimate Condition
Grade ≔ “6063-T6”
Fty ≔ 170 MPa tensile yield strength
Ftu ≔ 205 MPa tensile ultimate strength
Ωy ≔ 1.65 factor of safety for yielding
ASD building & similar type of structures
Ωu ≔ 1.95 factor of safety for rupture
ASD building & similar type of structures
G.3.2d Bearing Capacity of mullion
ADM 2020 Chapter J.3.6
de ≔ 80 mm edge distance
center of fastener to the edge of the material
Rn.1 ≔ de ⋅ tn.mw ⋅ Ftu = 37.72 kN nominal bearing strength
Rn.2 ≔ 2 ⋅ db ⋅ tn.mw ⋅ Ftu = 11.32 kN nominal bearing strength
Pbc ≔ min ⎛⎝Rn.1 , Rn.2⎞⎠ ÷ ⎛⎝Ωu ⋅ db ⋅ tn.mw⎞⎠ = 210.26 MPa allowable bearing strength
G.3.5b Shear line and tension line force on weld | Prepared by: KAQ | EOR: |
| Date: 10|12|2023 | Reg.No.: |
| | PTR.No.: |
| Checked by: HUG | PTR.Detail: |
| Date: 10|12|2023 | Tin.No.: |