Professional Documents
Culture Documents
JVC Ux-A70md Service Manual
JVC Ux-A70md Service Manual
JVC Ux-A70md Service Manual
SERVICE MANUAL
MICR COMPONENT MD SYSTEM
UX-A70MD
Contents
Adjustment method (CD/MD section)-----------------------1-2
1)CD section -------------------------------------------1-2
2)MD section-------------------------------------------1-3
No.20901B
COPYRIGHT 2001 VICTOR COMPANY OF JAPAN, LTD.
Downloaded from www.Manualslib.com manuals search engine Mar. 2001
UX-A70MD
2) CD section
(1) Indication of the C1 error
(2) Cancel of the C1 error indication
3) MD section
(1) Setup of the TEST MODE 1
(2) Initialization of the EEPROM
(3) Adjustment of the laser power
(4) Adjustment of the disk
(5) Setup of the TEST MODE 2
(6) Indication of variation in the pickup adjustment value
(7) Indication of the C1 error
(8) Cancel of the TEST MODE
FL indication
CRC = 0
200 Hz or less
FL indication
CRC = ***
1-2
Downloaded from www.Manualslib.com manuals search engine
UX-A70MD
2) MD section
FL indication
TEST MODE 1
(3) Adjustment of the playback laser power (4) Adjustment of the recording laser power
Increase the laser Decrease the laser Increase the laser Decrease the laser
power with the F. power with the B. power with the F. power with the B.
SKIP key on the SKIP key on the SKIP key on the SKIP key on the
remote controller. remote controller. remote controller. remote controller.
1-3
Downloaded from www.Manualslib.com manuals search engine
UX-A70MD
FL indication
ON TUNING
NO
Adjustment OK?
YES
FL indication FL indication
OK TUNING NG ERR: XX XX: Refer to the NG judgment code table.
FL indication FL indication
ON TUNING NG ERR: XX
Press the MD EJECT Automatic adjustment Press the POWER key on the Cut off the power supply after
key on the main unit. ends. main unit or remote controller. cancelling the TEST MODE.
1-4
Downloaded from www.Manualslib.com manuals search engine
UX-A70MD
FL indication
TEST MODE 2
FL indication
TEST MODE 2
Setup is complete.
(7) Indication of variation in the pickup adjustment value (8) Indication of the C1 error
FL indication*
XXXXX - XXXX 200 Hz or less
FL indication*
X X Y Y Z Z
* Each time the ASG -1
"6" key on the TRG -2
remote
TRB :
controller is
pressed, the FOB -128 (9) Cancel of the TEST MODE
indication FGR
(The cancel operation is common to the TEST
127
changes from MODE 1 and 2.)
FEXP 126
ASG to TRG, FGC
from TRG to
: Cut off the primary power supply to cancel the
TRB, and so FG 1 TEST MODE.
on as shown TGR 0
in the figure. TEXP
TGC
TG
1-5
Downloaded from www.Manualslib.com manuals search engine
UX-A70MD
(No.20901B) 200103
Downloaded from www.Manualslib.com manuals search engine