NOTES:

1. NOT TO SCALE,WORK TO DIMENSIONS ONLY.


2. IN CASE OF ANY DISCREPANCY BETWEEN
NO. OF BARS & SPACINGS, SPACINGS SHOULD
BE FOLLOWED.
3. ALL CONCRETE USED SHALL BE OF CONTROLLED
GRADE M-25 (U.O.S.) AS PER IS:456-2000.
4. BARS TO BE CUT & BENT NEAR OPENINGS/POCKETS.
5. ALL REINF. STEEL SHALL BE HYSD (Fe 500)
CONFIRMING TO IS:1786.
6. THE CLEAR COVER SHALL BE AS UNDER :
A. COLUMNS 40MM
B. FOOTINGS 50MM
C. BEAM 25MM
D. SLAB 15MM
7. THIS DRG. SHOULD BE READ IN CONJUNCTION
WITH ARCHITECT. ANY DISCREPANCY SHALL BE
REFERRED TO THE ARCHITECTS
AND GOT RECONCILED BEFORE EXECUTION.

8. LAP LENGHT/DEVELOPEMENT LENGTH FOR MAIN


REINFORCEMENT BARS AS PER IS:456-2000
SHALL BE 41X DIA OF BAR FOR M-25.
9. STRUCTURE DESIGNED FOR G+2 FLOORS ONLY.

Consultant:-
MSF ENGINEERING SOLUTIONS
CIVIL | MECHANICAL | ELECTRICAL |AUTOMATION | PMC

+
info@msfeso.com | Website: www.msfeso.com

Project:-

Architect:-

Designed by:-
Er.SHUAIB RANA
(M.Tech. struct.)
Dwg.Title:-

ARCHITECTURAL GRID PLAN


Checked by:-
ER. ADIL
Dealt by:-
SHAKEEL
Date :-
10/01/2022
JOB NO. Revision DWG. NO.

MSFES/0/000/22 R-0 001

You might also like