Plena Power Amplifiers Table of Contents | en 3

Table of contents
1 Safety 4
2 About this manual 5
2.1 Manual purpose 5
2.2 Digital document 5
2.3 Intended audience 5
2.4 Alerts and notice signs 5
2.5 Conversion tables 6
2.6 Copyright and disclaimer 6
2.7 Document history 6
3 System Overview 7
3.1 Product range introduction 7
3.2 Power amplifier range 7
4 Installation 8
5 Connection and indicators 9
5.1 Front panel indicators 9
5.2 Rear panel connectors and switches 9
5.3 Internal setting 11
6 External connections 12
6.1 Connect the back-up power supply 12
6.2 Connecting line input and loop-through 12
6.3 100V slave input 13
6.4 Constant voltage loudspeakers 13
6.5 Low impedance loudspeakers 14
6.6 Priority controlled loudspeaker 15
6.7 Power 15
7 Supervision 16
7.1 Input pilot tone 16
7.2 Battery supervision 16
7.3 Mains supervision 16
8 Operation 17
8.1 Switch ON 17
8.2 Connecting the priority input and using the control terminals 18
9 Maintenance 19
10 Technical data 20
10.1 Electrical 20
10.1.1 Mains voltage 20
10.1.2 Battery voltage 20
10.1.3 Rated power 20
10.2 Performance 20
10.2.1 Signal performance 20
10.2.2 Signal-to-Noise Ratios 20
10.2.3 Line inputs 21
10.2.4 Loudspeaker outputs 21
10.2.5 Power consumption 22
10.3 Mechanical specifications 24
10.4 Environmental conditions 24

Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0
4 en | Safety Plena Power Amplifiers

1 Safety
Prior to installing or operating products, always read the Important Safety Instructions which
are available as a separate multilingual document: Important Safety Instructions (Safety_ML).
These instructions are supplied together with all equipment that can be connected to the
mains supply.
Safety precautions
The Power Amplifier designed to be connected to the public distribution network.
– To avoid any risk of electric shock, all interventions must be carried out with
disconnected mains supply.
– The ventilation should not be impeded by covering the ventilation openings.
– Connection of external wiring to this equipment requires installation by qualified
personnel only.
– The operation must only be performed by qualified personnel.
– Use the apparatus in a moderate climate.

Caution!
These service instructions are for use by qualified service personnel only.
! To reduce the risk of electric shock, do not perform any servicing other than that contained in
the operating instructions unless you are qualified to do so.

2014.01 | V1.1 | LBB193x/x0 Installation and Operation manual Bosch Security Systems B.V.
Plena Power Amplifiers About this manual | en 5

2 About this manual


2.1 Manual purpose
The purpose of this manual is to provide information required for installing, configuring,
operating and maintaining the Plena Power Amplifier.

The following related documents are available:


– Plena Voice Alarm System Operation manual.
– Plena Voice Alarm System Software manual.

2.2 Digital document


This manual is available as a digital document in the Adobe Portable Document Format (PDF).
Refer to the product related information at: www.boschsecurity.com.

2.3 Intended audience


This manual is intended for installers, operators and users of a Plena system.

2.4 Alerts and notice signs


Four types of signs can be used in this manual. The type is closely related to the effect that
may be caused if it is not observed. These signs - from least severe effect to most severe
effect - are:

Notice!
Containing additional information. Usually, not observing a ‘notice’ does not result in damage
to the equipment or personal injuries.

Caution!
The equipment or the property can be damaged, or persons can be lightly injured if the alert
! is not observed.

Warning!

! The equipment or the property can be seriously damaged, or persons can be severely injured
if the alert is not observed.

Danger!
Not observing the alert can lead to severe injuries or death.

Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0
6 en | About this manual Plena Power Amplifiers

2.5 Conversion tables


In this manual, SI units are used to express lengths, masses, temperatures etc. These can be
converted to non-metric units using the information provided below.

1 in = 25.4 mm 1 mm = 0.03937 in

1 in = 2.54 cm 1 cm = 0.3937 in

1 ft = 0.3048 m 1m= 3.281 ft

1 mi = 1.609 km 1 km = 0.622 mi
Table 2.1: Conversion of units of length

1 lb = 0.4536 kg 1 kg = 2.2046 lb
Table 2.2: Conversion of units of mass

1 psi = 68.95 hPa 1 hPa = 0.0145 psi


Table 2.3: Conversion of units of pressure

Notice!
1 hPa = 1 mbar

9
_
°F = . °C + 32
5

5
_
°C = . (°F - 32)
9

2.6 Copyright and disclaimer


All rights reserved. No part of this document may be reproduced or transmitted in any form by
any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior
written permission of the publisher. For information on getting permission for reprints and
excerpts, contact Bosch Security Systems B.V..
The content and illustrations are subject to change without prior notice.

2.7 Document history


Release date Documentation version Reason

2014.01.10 V1.0 1st edition.

2014.01.21 V1.1 2nd edition. Minor technical


data changes.

2014.01 | V1.1 | LBB193x/x0 Installation and Operation manual Bosch Security Systems B.V.
Plena Power Amplifiers System Overview | en 7

3 System Overview
3.1 Product range introduction
The Power Amplifier is part of the Plena product range. The Plena product range provides
public address solutions for places where people gather to work, worship, trade, or to relax. It
is a family of system elements that are combined to create public address systems tailored for
virtually any application. The Plena product range includes:
– Mixers
– Pre‑amplifiers
– Power amplifiers
– Music source unit
– Digital message manager
– Feedback suppressor
– Call stations
– "All-In-One" system
– Voice Alarm System
– Timer
– Charger
– Loop amplifier
The various elements are designed to complement each other using matched acoustical,
electrical and mechanical specifications.

All Plena Power Amplifiers in this manual are designed for use in EN54‑16 and EN60849
compliant systems.

3.2 Power amplifier range


The Plena Power Amplifier range consists of the following mono amplifiers:
– 120W LBB 1930/20 (2 units high).
– 240W LBB 1935/20 (2 units high).
– 480W LBB 1938/x0 (3 units high).

In this manual all illustrations show either the LBB 1938/x0 power amplifier that is 3 units
high, the LBB 1930/20, LBB 1935/20 power amplifier that is 2 units high. All connections are
similar between the different power amplifiers. These power amplifiers have 70V and 100V
constant voltage outputs and a low impedance output for 4 or 8 Ohm loudspeakers.
Two inputs, "Priority" and "Program", give priority and controlled outputs. A 100V slave input
gives connection to existing loudspeaker lines. The line inputs are balanced and have a
loop‑through facility. The amplifiers have overload and short‑circuit protection. A temperature
controlled fan and overheat protection gives high reliability. Battery operation with automatic
switchover from the mains supply is available.

Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0
8 en | Installation Plena Power Amplifiers

4 Installation
The power amplifier is intended for tabletop use, however the unit can also be mounted in a
19” rack. For 19" rack installation; use:
– The 19" rack mounting brackets which come with the product.
– Standard M6 mounting screws: 16 mm thread depth, 20 mm total length.
The power amplifier has an internal fan regulated to keep the temperature inside the unit
within safe operating conditions.

0 dB
-6 dB
-20 dB

Figure 4.1: Brackets for 19" rack mounting

Notice!
If you install the product into a 19” rack:
- Ensure that it does not exceed the overheating temperature (+45°C ambient).
- Make sure that warm air that is expelled from the side and rear can flow away.
- Ensure sufficient ventilation and enough room, about 10cm / 4” behind the unit for cables
and connections.
- Use the included Bosch 19” mounting brackets (LBC 1901/00) x2.
- Remove the tabletop feet from the bottom of the unit.

2014.01 | V1.1 | LBB193x/x0 Installation and Operation manual Bosch Security Systems B.V.
Plena Power Amplifiers Connection and indicators | en 9

5 Connection and indicators


5.1 Front panel indicators
1 2 3 4 5 6

0 dB
-6 dB
-20 dB Status

Pilot-Tone B a tte ry Mains O v e r he a t

Figure 5.1: LBB 1930/20 LBB 1935/20 and LBB 1938/20

1. VU meter LED’s for -20, -6, 0dB and power ON.


2. Pilot‑Tone supervised function that monitors a 20 kHz pilot tone.
3. Battery supervised function to indicate battery operation.
4. Mains supervised function to indicate mains supply.
5. Overheat supervised function to give warning of overheating.
6. Air inlet cooling is made by forced ventilation from front to back. Amplifiers can be
stacked on top of each other. A supply of cool air from the front is necessary.

5.2 Rear panel connectors and switches


20 19 18 17 16 15 14 13

Input 1 Input 2 Slave Input Fault Relays' Output Apparatus delivered


Priority Enable 100V
Pilot-tone
Detector
Input Battery Main Power
Battery
Detection
connectored for 230V~
230V~ 240V~
Power
12
OffOn NO COM NC NO COM NC NO COM NC OffOn 100V
Rated input
0 Power : 1600VA
Input 1 Priority

Loopthrough 1
2..24V GND 2..24V GND 100V 0
Direct O utput
100V 0 70V 0 8
70V
0
8ohm 11
F702
F701

Input 2 Program 100V/70V

Loopthrough 2
Default Off Default On S election (12A)

Priority Only
Input 1 Priority
2...24V- Input 1
+
-
Input 1-Priority Input 2-Program 0
No Priority
0
0V- Input 2
Input 2 Enable + Priority
2..24V- Enable -
0V- Mute
S lave Input 100V 100V
0
Priority Controlled Output 24V DC In
100V 0 1 00V 0 10

Input Input Priority Only No Priority

1 2 3 4 5 6 7 8 9
Figure 5.2: LBB 1930/20 LBB 1935/20

Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0
10 en | Connection and indicators Plena Power Amplifiers

20 19 18 17 16 15 14

Input 1 Priority Fault Relays' Output Power

Input 1 Input 2 Slave Input


Priority Enable 100V
Loopthrough 1

Input 2 Program
Loopthrough 2
Pilot-tone
Detector
Input Battery Main Power
Battery
Detection
12
Input 1 Priority +
2...24V- Input 1 -
0V- Input 2 OffOn NO COM NC NO COM NC NO COM NC OffOn
Input 2 Enable +
2..24V- Enable -
0V- Mute
Apparatus
delivered
2..24V GND 2..24V GND 100V 0
Slave Input 100V 100V
0
100V
0 100V
Direct O utput
0 70V 0 8
connectored
for 230V~
11
Default Off Default On 70V
0
8ohm
Input 1-Priority Input 2-Progr am

F702
F701
100V/70V
Selection (12A) Rated input
Priority Only
0
No Priority Priority Controlled Output
Power : 1600VA
10
0 24V DC In
Priority

100V 0V 100V 0V

Input Input
Priority Only No Priority 8
Input Output

1 2 3 4 5 6 7 9

Figure 5.3: LBB 1938/x0

Note that slight deviations from the rear panel layout shown may occur.
1. Priority line input 1 (XLR/balanced)
2. Level control input 1
3. Priority loopthrough output 1 (XLR/balanced)
4. Program line input 2 (XLR/balanced)
5. Level control input 2
6. Program loopthrough output 2 (XLR/balanced)
7. Priority controlled loudspeaker output terminals
8. 24 Vdc power supply terminals
9. Earth connection screw
10. Mains fuse (T10A)
11. Mains connector (3-pole)
12. ON - OFF switch
13. Voltageselector (Not on LBB 1938/x0)
14. Loudspeaker direct output terminals
15. Battery detection
16. Fault relay output
17. Pilot-Tone detection
18. 100 V slave input terminals
19. Input 2 enable control terminals
20. Input 1 priority control terminals

2014.01 | V1.1 | LBB193x/x0 Installation and Operation manual Bosch Security Systems B.V.
Plena Power Amplifiers Connection and indicators | en 11

5.3 Internal setting


The output voltage of the priority controlled loudspeaker outputs can be set to 70V or 100V. A
high power fuse inside the unit is used as a voltage selector. Insert the high power fuse into
fuse holder F701 for 100V selection (default setting), or into fuse holder F702 for 70V
selection. This selection does not affect the output voltage of the loudspeaker direct outputs.

F701 100V

F702 70V

Figure 5.4: Internal fuse setting LBB 1930/20, LBB 1935/20, LBB 1938/x0

See also
– Rear panel connectors and switches, page 9

Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0
12 en | External connections Plena Power Amplifiers

6 External connections
6.1 Connect the back-up power supply
The power amplifier has a 24VDC input (8) screw terminal to connect a back-up power supply.
You must connect an earth (9) to the unit to increase the electrical stability of the system.

elays'
O utp
t B atte ut
ry Main
Power
Input
1
Batter P riority Input 2 S
E na ble lave Input

Detect y
100V
App
NC NO ion connecaratus deliv Input
1 Priority
Fault
R elays'
C OM tore ered Loopthrough
1
Pilot-ton Outpu
23 0V~ d for 230
Input
2 Program
NC NO Loopthrough Detectoe Input
B attery t
COM r
V~
2
Input Main Power
NC 1 Priority
2...24V- 2. . 24V

Off On 24 0V~ 0V- InputInput 1


Input
2
2
2..24V- Enable
+
-
Defa G ND 2. . 24V
Input
ult O
ff Defa G ND 100V
ult O 0
Off On B attery
Detectio Apparatus
0V- MuteEnable +
- 1-Priority
n NO C
OM NC NO n connector delivered

Pow er 230V~ ed for 23 0V~


Slave C OM
Input NC NO
100V 100V COM
NC
0 O ff O 240V~

Dir ect
n
Input Power
2-P rogra Direct

10 0V O utp m 100 V
0
O utput

ut 70V
0 8
100V
0

0
70V
0
R ated

70 V
8ohm input
Input

F701

F702
100V/70V
Selection Power
(12A) : 1600VA

0 100V Priority
Contro
Priority
0 Only

8 0
70V Input
100V
0
lled O
1 00V
utput
24V DC
Priority
No Priority
0

0 0 In
R ated
8ohm input
F701

Power
F702

100V/70
Selectio
V : 160
n (12A) 0VA
Priority Priority

100V
Controlle 0 Only
No Priority

0 d O utp 0

ut 24 Priority

10 0V V DC
0 In

-
+

12 VD
-
C +

12 VD
C

Figure 6.1: Back‑up power supply

6.2 Connecting line input and loop-through


The power amplifier has a balanced line input for connection to a pre‑amplifier or a mixer. Use
the loop‑through connection to connect the power amplifier to another power amplifier if
more power is needed. Each power amplifier must be connected to its own set of
loudspeakers. Do not connect power outputs to each other.
Use program line input 2 (4) and line loop‑through 2 (6) for normal operation without priority.

T el/E
MG T rigger
1 T rigger
2

/Line 0
1.Aud
2.0V io+ 5.Allc
3.Aud all
6.Da
ta-
4.24V io- 7.Da
d.c. ta+
/Line 8.C hs.G P C Audio
ND In
1- R S 232
Zone
33 CD
4 5
5 5 4
1
L Zone
2
6
C all Appa
+ Aux Active ratus
G ND C all conne delive
2
- 1 G ND In red
7
6 + cted
3 8 R 3 1
- 100V In for 230V
- 115V - 230V
1 2
5
3
0
2
4
Zone 100V -
1
0
Mas terO Zone
2
ut Zone 100V
3 0
Out Zone 100V
4 0
100V DC Out
0
100V DC In
0
100V
0
100V
0
+24V
-
+24V
- R ated
Warni input
ng P ower
T his : 50V
appara A
tus mus T 1.0AL
t be earthe 250V
d

4 6

LBB 1938/1 LBB 1


938/10
Ple Plena
Max. output wer Inpu t 480W
Max. output Power
8900
193 81001 Inpu t
Amplifier 1 Amplifier 1
P riori Inpu t 2 S P riori Inpu t 2 S
R ated power R ated power
720W output 720W
230V~ utp t ow 230V~ power
,50/ r 180W
ty E na lave ,50/60Hz 180W
ty E na lave
Made in C hina

S /N.
ble 100V Inpu t ble 100V Inpu t
A035413 A035413
Made in

Design Design
The & Quality N 6
NL-4827HG
& Quality
The Netherlands N663
NL-4827HG
er an -10 -10

Input Input
1 Priority
Fault R 1 Priority
Fault R
Loopthro
ugh 1 elays' Loopthro
ugh 1 elays'
Input
2 Program Pilot-tone Output Input
2 Program Pilot-tone O utpu
Loopthro
ugh 2 Detector Input
B attery
Loopthro
ugh 2 Detector Input
B attery
t
Input
1 Priority
2...24V- 2. . 24V Main Powe Input
1 Priority
2...24V- 2. . 24V Main Powe
0V- InputInput 1 +
Defa G ND 2. . 24V r 0V- InputInput 1 +
Defa G ND 2. . 24V r
2 - ult O B attery 2 - ult O B attery
Input ff Defa G ND 100V O ff O Input ff Defa G ND 100V O ff O
2
2..24V- Enable
+ Inpu t ult O
n 0 n Detection Appar
2
2..24V- Enable
+ Inpu t ult O
n 0 n Detection Appar
0V- MuteEnable
- 1-P riority NO C
O M NC conne atus deliver
ctored
0V- MuteEnable
- 1-Priority NO C
O M NC conne atus deliver
ctored
Slave
Input
NO C
O M NC
230V~ for 230V~ ed Slave
Input
NO C
OM NC NO 230V~ for 230V~ ed
100V 100V NO C 100V 100V COM
OM NC NC
0 Off O 240V~ 0 O ff O 240V~
n n
Inpu t Powe Inpu t Powe
2-P rogr Dire ct r 2-P rogr Dire ct r
am O utpu am O utpu
100V t 100V t
0 70V 0 70V
0 8
100V
0 0 8
100V
0
70V 70V
0 0
R ated R ated
8ohm input 8ohm input
F701

F701

Inpu t Inpu t
F702

F702

100V/70V Power 100V/70V Power


Selection : 16 00V Selection : 1600V
(12A) A (12A) A
Priority Priority Priority Priority

10 0V
Controlle 0 Only
No Priority
10 0V
Controlle 0 Only
No Priority

0 d O utpu 0

0 d Output 0

Inpu t 1 00V t 24V


Priority
Inpu t 24V DC
Priority

DC In 1 00V
0 0 In

Figure 6.2: Line input and loop‑through

2014.01 | V1.1 | LBB193x/x0 Installation and Operation manual Bosch Security Systems B.V.
Plena Power Amplifiers External connections | en 13

6.3 100V slave input


The power amplifiers have a 100V slave input (18) that can be connected to an existing 100V
loudspeaker line. In this way it is easy to connect an additional power amplifier on a remote
location for more output power. The 100V input is not affected by the control terminals for
input 1 priority (20) or input 2 enable (19).

Input 1 Input 2 S lave Input Fault Relays' Output Apparatus delivered


2. . 24V G ND 2. . 24V G ND 100V 0 LBB 1938/10 8900 193 81001
P riority E na ble 100V Input Battery Main Power
connectored for 230V~
Power
230V~ 240V~
D e fa ult O ff D e fa ult O n Pilot-tone Battery

Made in China
Plena 480W P ower Amplifier
Max. output power 720W
Rated output power 180W A035413
Detector Detection
230V~,50/60Hz
N663
S/N. NL-4827HG-10
Design & Quality
The Netherlands
OffOn NO COM NC NO COM NC NO COM NC OffOn 100V
Rated input
0 Power : 1600VA
Input 1 Priority D ire ct O utput 70V
0
8ohm
Loopthrough 1
2. . 24V G ND 2. . 24V G ND 100V 0 100V 0 70V 0 8

F702
F701
Input 2 Program 100V/70V

Loopthrough 2
D e fa ult O ff D e fa ult O n S election (12A)

Priority Only
Input 1 Priority
2...24V- Input 1
+
-
Input 1-P r iority Input 2-P rogra m 0
No Priority
0
0V- Input 2
Input 2 Enable + Priority
2..24V- Enable -
0V- Mute
S lave Input 100V 100V Priority Controlled Output 24V DC In
0

100V 0 100V 0

Input Input Priority Only No Priority

Figure 6.3: 100 V slave input

Notice!
If the 100V slave input is used, and the 0V and 100V are incorrectly connected, no pilot tone
is detected on the power amplifier. Refer to section Input pilot tone, page 16, for more
information.

6.4 Constant voltage loudspeakers


The power amplifier can drive 100V constant voltage loudspeakers at full power (100V) or half
power (70V). Connect the loudspeakers in parallel and check the loudspeaker polarity for in-
phase connection. The summed loudspeaker power should not exceed the rated amplifier
power.

Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0
14 en | External connections Plena Power Amplifiers

6.5 Low impedance loudspeakers


Connect low impedance loudspeakers to the 8 ohm/0 terminals. This output can deliver the
rated output power into an 8 ohm load. Connect multiple loudspeakers in a series/parallel-
arrangement to make the combined impedance 8 ohm or higher. Check the loudspeaker
polarity for in‑phase connection.

8 Ohm

8 Ohm 8 Ohm
8 Ohm 8 Ohm

100 V 70 V 4 Ohm
4 Ohm

8 Ohm

LBB 1938/10
Plena
480W
Max. output Power
8900
193 81001 Inpu t
1
P riori Inpu t 2 S
Amplifier
R ated power
output 720W
230V~ power
ty E na lave

Made in C hina
,50/60Hz 180 W
S /N.

Design
A035413

ble 100V Inpu t


& Q uality
The Netherlands N6 63
NL-4827HG
-10

Input
1 Priority
Loopthrou
Fault Re
Input
gh 1
Pilot-tone lays' O utpu
2 Program
Loopthrou
gh 2 Detector Input
B attery
t
Input
1 Priority
2...24V- 2. . 24V Main Powe
0V- InputInput 1 +
Defa ultG ND 2. . 24V r
2 -
O G O ff O B attery
Inpu t ff Defa ult ONDn 100V
Input
2
2..24V- Enable n
0V- MuteEnable +
1-P 0 Detection Appara
-
riori ty NO C
OM NC NO connec tus deliver
Slave C OM tored ed
Input
100V 100V
NC NO
COM 230V~ for 230V~
NC
0 Off O 240V~
n
Inpu t Powe
2-P rogr Dire ct r
am O utpu
100V t
0 70V
0 8
100V
0
70V
0
R ated
8ohm input

F701
Inpu t

F702
100V/70V Power
Selection
(12A)
: 1600V
A
Priority Priority
Only

100V
Controlle 0
No Priority

0 d O utpu 0

Inpu t 1 00V t 24V


Priority

0
DC In

D ire ct O utput
100V 0 70V 0 8

Priority Controlled Output 24V DCIn


100V 0 100V 0

Priority Only No Priority

Priority Only No Priority

Figure 6.4: Priority input and control terminals

2014.01 | V1.1 | LBB193x/x0 Installation and Operation manual Bosch Security Systems B.V.
Plena Power Amplifiers External connections | en 15

6.6 Priority controlled loudspeaker


Loudspeakers connected to the Priority Only output will receive only audio signals with
priority, like calls from a call station.
Loudspeakers connected to the No Priority output will receive all audio signals, such as music,
but no signals with priority, like calls.

6.7 Power
Use the mains lead to connect the amplifier to the power supply.

LBB 1
938/10
Plena
480W
Max. output Power
8900
193 81001 Input
Amplifier 1
P riority Input 2 S
R ated power
output 720W
230V~ power
,50/60Hz 180W
E na ble lave Input

Made in C hina
S /N. A035413

Design
& Q uality
The Netherlands NL-4827HG
N663
100V
-10

Input
1 Priority
Fault
Loopthrough
Relays
Input
2 Program
1
Pilot-ton ' Outpu
Loopthrough
Detectoe Input
B attery t
Input
2
1 Priority 2. . 24V r Main Power
2...24V-
0V- InputInput 1 +
Defa G ND 2. . 24V

elays' ult O
-
Input
2
ff Defa G ND 100V O ff On B attery
2
2..24V- Enable
+ Input ult O
n 0 Detectio Apparatus
0V- MuteEnable
1-P riority NO C

Outp ut Slave
- OM NC NO n connector delivered
230V~ ed for 23 0V~
C OM
Input NC NO
100V 100V COM
NC
0 O ff On 240V~
Input Power
2-P rogra Direct
t B att m 100V O utput

ery Main Po
0 70V
0 8
100V
0
70V
0
R ated

wer input
8ohm

Input

F701

F702
100V/70V
Selection Power
(12A) : 1600VA
Priority Priority
0 Only
Contro
B attery 10 0V No Priority
lled O 0

Input 0 utput Priority

1 00V 24V DC
0 In
Detec App
NC NO
tion connecara tus deliver
tor ed
23 0V~ ed for 230
C OM
NC NO
COM
NC V~
Off On 240 V~
Powe
Di re ct r
10 0V O utpu
0
t
70 V 100V
0 8 0
70V
0
Rated
8ohm input
Powe
F701

F702

100V/7
Selec
0V r : 1 600
tion (12A) VA
Priority Priorit
y Only

10 0V
Control 0
No Priorit
led Outp ut
0 y

0 Line Priorit
y

10 0V 24 V DC
T10In
fus e
0 L2 50
V

Figure 6.5: Mains lead

Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0
16 en | Supervision Plena Power Amplifiers

7 Supervision
Supervision is provided for:
– Pre‑amplifier and power amplifier function
– Battery and mains supervision
Relays are provided on the rear panel for the each supervised function and are normally
energized (fail‑safe). Each relay has 3 contacts, normally open, common and normally closed.
If an application does not need supervision, the indicators on the front panel can be set to
“OFF” with the switches next to each relay output. The relays always function and are
independent of the indicator switch setting.

7.1 Input pilot tone


The Plena Voice Alarm System uses a pilot tone of 20kHz at -20dBV to supervise the pre-
amplifier, the connections between the pre‑amplifier and the power amplifier and function of
the power amplifier. If the input signal from the pre‑amplifier stops, the mains and battery fail,
or the power amplifier stops for any other reason, the pilot‑tone stops, the pilot‑tone fault
indication shows on the front panel and a signal is given on the Input fault relay. If the power
amplifier stops through overheat, then the overheat indicator shows on the front panel, the
signal is given on the Input fault relay.

The pilot‑tone detection indicator can be set to “ON” or “OFF” with the pilot‑tone detection
switch (17), see Rear panel connectors and switches, page 9. The pilot‑tone indicator on the
front panel is set to “OFF”, but the fault relay switch still functions.

7.2 Battery supervision


The power amplifier supervises the availability of the back‑up power supply.
If the battery supply fails the battery fault indication shows on the front panel and the battery
fault relay switches over.

The battery supervision indicator can be set to “ON” or “OFF” with the battery detection
switch (15), Rear panel connectors and switches, page 9. The battery indicator on the front
panel is set to “OFF”, but the fault relay switch still functions.

The amplifier will work between 20VDC and 26.5VDC. Below 20VDC the amplifier will shut
down if the mains is not present.

The amplifier will automatically switch from primary power (mains) to backup power (24VDC),
this changeover is automatic. During switch over a glitch can be heard in the audio signal,
typically this lasts less than 1 second, maximum 2 seconds duration.

7.3 Mains supervision


The power amplifier supervises the availability of the mains supply. If the mains supply fails
(falls below the threshold of -20%), and the back‑up power supply takes over, the fault relay
moves to the NOK position. A mains fault indication shows on the front panel and a fault state
is given by the mains fault relay.

2014.01 | V1.1 | LBB193x/x0 Installation and Operation manual Bosch Security Systems B.V.
Plena Power Amplifiers Operation | en 17

8 Operation
8.1 Switch ON
Put the power switch on the rear of the power amplifier in the “I” position.

LBB 1
938/10
Plena
480W
Max. output Power
8900
193 81001 Input
Amplifier 1
P riority Input 2 S
R ated power
output 720W
230V~ power
,50/60Hz 180W
E na ble lave Input

Made in C hina
S /N. A035413

Design
& Q uality
The Netherlands NL-4827HG
N663
100V
-10

Input
1 Priority
Fault
Loopthrough
Relays
Input
2 Program
1
Pilot-ton ' Outpu
Loopthrough
Detectoe Input
B attery t
Input
2
1 Priority 2. . 24V r Main Power
2...24V-
0V- InputInput 1 +
Defa G ND 2. . 24V

elays' ult O
-
Input
2
ff Defa G ND 100V O ff On B attery
2
2..24V- Enable
+ Input ult O
n 0 Detectio Apparatus
0V- MuteEnable
1-P riority NO C

Outp ut Slave
- OM NC NO n connector delivered
230V~ ed for 23 0V~
C OM
Input NC NO
100V 100V COM
NC
0 O ff On 240V~
Input Power
2-P rogra Direct
t B att m 100V O utput

ery Main Po
0 70V
0 8
100V
0
70V
0
R ated

wer input
8ohm

Input

F701

F702
100V/70V
Selection Power
(12A) : 1600VA
Priority Priority
0 Only
Contro
B attery 10 0V No Priority
lled O 0

Input 0 utput Priority

1 00V 24V DC
0 In
Detec App
NC NO
tion connecara tus deliver
tor ed
23 0V~ ed for 230
C OM
NC NO
COM
NC V~
Off On 240 V~
Powe
Di re ct r
10 0V O utpu
0
t
70 V 100V
0 8 0
70V
0
Rated
8ohm input
Powe
F701

F702

100V/7
Selec
0V r : 1 600
tion (12A) VA
Priority Priorit
y Only

10 0V
Control 0
No Priorit
led Outp ut
0 y

0 LinePriority
10 0V 24 V DC
T10In
fus e
0 L2 50
V

Figure 8.1: Power switch and power connection

1 2 3 4 5 6

0 dB
-6 dB
-20 dB Status

Pilot-Tone B a tte ry Mains O v e r he a t

Figure 8.2: LBB 1930/20 LBB 1935/20, LBB 1938/x0

If mains power or back‑up power is available, the VU‑bar (1) on the front of the power
amplifier is lit and shows the output level of the amplifier.

If the internal temperature reaches a critical limit due to poor ventilation or overload, an
overheat protection circuit switches “OFF” the power stage. The overheat indicator (5) shows
on the front panel and the Input fault relay switches over if the power stage is switched “OFF”
by the overheat protection circuit. The Battery operation indicator (3) lights up if the mains
power supply is failing and the back‑up battery is in use.

Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0
18 en | Operation Plena Power Amplifiers

8.2 Connecting the priority input and using the control terminals
The power amplifier is provided with a balanced priority input (Input 1‑Priority) to connect to
a pre‑amplifier or mixer.
Refer to figure 5.2 and 5.3. Apply a control voltage of 2...24V to the input 1 priority control
terminals (20) to switch “ON” the priority input (1) and mute the program input (4). A local
music source can be connected to the program input and a remote emergency system to the
priority input. The emergency source must be able to supply the 2…24V control voltage to
override the local music source. The program input can be remotely controlled by using a
switch that is connected to the input 2 enable control terminals (19). Closing the switch
forces the input to <2V and disables the program input.

Application example of the use of the power amplifier control terminals


You can use up to 6 power amplifiers in combination with the Plena LBB1925/10 System
Pre‑amplifier to build a powerful multi-zone sound system. Zone switching of BGM and calls is
done via the LBB1925/10 zone relays in combination with the power amplifier control
terminals. The LBB1925/10 controls the background music by distributing 24VDC via the
music zone relays to the input 2 enable control terminals (19).The LBB1925/10 controls the
calls by distributing 24VDC via the call zone relays to the input 1 priority control terminals
(20). Each power amplifier serves one loudspeaker zone. Each zone can be “OFF”, or receive
music or a call.

LBB1925/10
Apparatus delivered 115V 230V
Tel/EMG Trigger 1 Trigger 2 LBB1925/10 connected for 230V-
890019251005
115/230V~,50/60Hz
No.

0
1. Audio+ 5. Allcall
RS232 CD A ux
2.0V 6.Data- 100V 0 100V 0 100V 0 100V 0
/Line PCAudoln
3.Audio- 7.Data+
4.24Vd.c. 8.Chs.GND

/Line L + GND GND +


2 - 1 1 - 2
3 3 Rated Input
Power : 50VA
T0.5L 250V
R 100V 0 100V 0 100V 0 100V 0 +24V- +24V-
7 6
Warning
1- 3 3 1 3 8 1
5 4 5 4 MasterOut Out This apparatus must be earthed
4 5 2 2

Input 1 Input 2 S lave Input Fault Relays' Output Apparatus delivered Input 1 Input 2 S lave Input Fault Relays' Output Apparatus delivered
LBB 1938/10 8900 193 81001
P riority E na ble 100V Input Battery Main Power
connectored for 230V~
Power LBB 1938/10 8900 193 81001
P riority E na ble 100V Input Battery Main Power
connectored for 230V~
Power
230V~ 240V~ 230V~ 240V~
Pilot-tone Battery Pilot-tone Battery
Made in China

Made in China

Plena 480W P ower Amplifier Plena 480W P ower Amplifier


Max. output power 720W
Rated output power 180W A035413
Detector Detection Max. output power 720W
Rated output power 180W A035413
Detector Detection
230V~,50/60Hz 230V~,50/60Hz
N663 N663
S/N. NL-4827HG-10 S/N. NL-4827HG-10
Design & Quality Design & Quality
The Netherlands The Netherlands
OffOn NO COM NC NO COM NC NO COM NC OffOn 100V
Rated input OffOn NO COM NC NO COM NC NO COM NC OffOn 100V
Rated input
0 Power : 1600VA 0 Power : 1600VA
Input 1 Priority D ire ct O utput 70V
0 Input 1 Priority D ire ct O utput 70V
0
8ohm 8ohm
Loopthrough 1 Loopthrough 1
2. . 24V G ND 2. . 24V G ND 100V 0 100V 0 70V 0 8 2. . 24V G ND 2. . 24V G ND 100V 0 100V 0 70V 0 8
F701

F702

F701

F702

Input 2 Program 100V/70V Input 2 Program 100V/70V

Loopthrough 2
D e fa ult O ff D e fa ult O n S election (12A)
Loopthrough 2
D e fa ult O ff D e fa ult O n S election (12A)

Priority Only Priority Only


Input 1 Priority
2...24V- Input 1
+
-
Input 1-P r iority Input 2-P rogra m 0
No Priority
0
Input 1 Priority
2...24V- Input 1
+
-
Input 1-P r iority Input 2-P rogra m 0
No Priority
0
0V- Input 2 0V- Input 2
Input 2 Enable + Priority Input 2 Enable + Priority
2..24V- Enable - 2..24V- Enable -
0V- Mute 0V- Mute
S lave Input 100V 100V Priority Controlled Output 24V DC In S lave Input 100V 100V Priority Controlled Output 24V DC In
0 0

100V 0 1 00V 0 100V 0 1 00V 0

Input Input Priority Only No Priority Input Input Priority Only No Priority

Figure 8.3: LBB1925/10 and power amplifier control terminals example

2014.01 | V1.1 | LBB193x/x0 Installation and Operation manual Bosch Security Systems B.V.
Plena Power Amplifiers Maintenance | en 19

9 Maintenance
The units require minimum maintenance, however to keep the units in good condition, the
following tasks should be carried out.
– Clean the units:
– Periodically clean the units with a damp, lint-free cloth.
– Clean the air inlets:
– The units can collect dust from the operation of the internal fans. The air inlets of the
units should therefore be cleaned on a yearly basis.
– Periodically check unit connections and grounding:
– To ensure that all cable connections to the units are secure.
– The ground (Protective Earth) connection of the system components.

Warning!

! Dangerous mains voltages are present inside the units. Disconnect the main power supply
before doing any maintenance tasks.

Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0
20 en | Technical data Plena Power Amplifiers

10 Technical data
10.1 Electrical

10.1.1 Mains voltage


LBB 1930/20 LBB 1935/20 230 / 115 VAC , ± 10%, 50 – 60 Hz

LBB 1938/20 230 VAC, 50 – 60 Hz

LBB 1938/70 110 VAC, 50 – 60 Hz

10.1.2 Battery voltage


Battery voltage 24V DC, 20 - 26.5 V

10.1.3 Rated power


LBB 1930/20 400 VA

LBB 1935/20 960 VA

LBB 1938/x0 1600 VA

10.2 Performance

10.2.1 Signal performance


Frequency response 50 Hz - 20 kHz (+1/-3 dB @ -10 dB ref. rated
output)

Distortion <1% @ rated output, 1 kHz

10.2.2 Signal-to-Noise Ratios


LBB 1930/20 > 80 dB

LBB 1935/20 > 85 dB

LBB 1938/x0 > 90 dB

2014.01 | V1.1 | LBB193x/x0 Installation and Operation manual Bosch Security Systems B.V.
Plena Power Amplifiers Technical data | en 21

10.2.3 Line inputs


3 pin XLR balanced

Sensitivity 1V

Impedance 20 kohm

CMRR > 40 dB (50 Hz - 20 kHz)

100V input, screw unbalanced

Sensitivity 100 V

Impedance 330 kohm

10.2.4 Loudspeaker outputs


Line loopthrough output (3 pin XLR balanced)

Nominal level 1V

Impedance Direct connection to line input

Maximum rated output power - 70/100V output

LBB 1930/20 240 W

LBB 1935/20 240 W

LBB 1938/x0 480 W

8 Ohm outputs

LBB 1930/20 31 V / 120 W

LBB 1935/20 44 V / 240 W

LBB 1938/x0 62 V / 480 W

Power reduction@24 V battery operations

Reference rated power -1 dB (LBB 1935/20)


-2 dB (LBB 1930/20 LBB 1938/x0)

Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0
22 en | Technical data Plena Power Amplifiers

10.2.5 Power consumption


Power (mains) LBB 1930/20 Unit

Full power 274 Watt

- 3 dB 193 Watt

- 6 dB 143** Watt

10V 41 Watt

Idle 18 Watt

Backup power
(24VDC)

Full power 7 Amp

- 3 dB 6 Amp

- 6 dB 4** Amp

10V 1 Amp

Idle 0.1 Amp

Full power 168 Watt

- 3 dB 144 Watt

- 6 dB 96 Watt

10V 24 Watt

Idle 2.4 Watt

Power (mains) LBB 1935/20 LBB 1938/x0 Unit

Full power 451 987 Watt

- 3 dB 340 715 Watt

- 6 dB 244** 508** Watt

10V 55 113 Watt

Idle 16 25 Watt

Backup power
(24VDC)

Full power 12 32 Amp

- 3 dB 11 26 Amp

- 6 dB 8** 18** Amp

10V 2 4 Amp

Idle 0.3 1 Amp

Full power 288 768 Watt

2014.01 | V1.1 | LBB193x/x0 Installation and Operation manual Bosch Security Systems B.V.
Plena Power Amplifiers Technical data | en 23

Power (mains) LBB 1935/20 LBB 1938/x0 Unit

- 3 dB 264 624 Watt

- 6 dB 192 432 Watt

10V 48 96 Watt

Idle 7.2 24 Watt

* Output limited to -3dB


** Corresponds to pink noise and voice on full power
*** Output limited for sine wave signal to -3dB

Bosch Security Systems B.V. Installation and Operation manual 2014.01 | V1.1 | LBB193x/x0
24 en | Technical data Plena Power Amplifiers

10.3 Mechanical specifications


Dimensions

Width 19”

Height (including feet) 2 Unit models: 100 mm


3 Unit models: 145 mm

Depth 2 Unit models: 250 mm


3 Unit models: 370 mm

19" Mounting brackets Included

Weight

LBB 1930/20 10.5 kg

LBB 1935/20 12.5 kg

LBB 1938/x0 25.0 kg

10.4 Environmental conditions


Operating temperature range -10 to +55°C

Storage temperature range -40 to +70°C

Relative humidity < 95%

EMC emission According to EN55103‑1

EMC immunity According to EN55103‑2

Acoustic noise level of fan < 45 dB SPL @ 1m at maximum speed

2014.01 | V1.1 | LBB193x/x0 Installation and Operation manual Bosch Security Systems B.V.
Bosch Security Systems B.V.
Torenallee 49
5617 BA Eindhoven
The Netherlands
www.boschsecurity.com
© Bosch Security Systems B.V., 2014

You might also like