Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Comprehensive Service

»» Exhaustive survey of your system under working »» On-site analyses and treatment control
conditions »» RO-Soft program for best definition of treatment
»» Membrane autopsy with full report and dose rate
»» Water analysis, including calculation of the scaling »» Specific cleaning programs
tendency »» Plant audits
»» Deposit analysis »» Jar test, for the selection of the best pre-treatment
»» Microbial analysis, including identification of type
»» HydroBio® test kit, especially developed for the Osmotech® can be applied not only in RO units but
determination of biofilm in water systems also in other membrane processes (ultrafiltration,
»» Pilot plants scale up (process design) nanofiltration)

For reverse osmosis and


other membrane processes Osmotech®

Headquarters Germany China Iberica Poland, Romania, Baltics,


North, Central and South East Kurita Water Industries (Jiangyin) Kurita Iberica SL. Ukraine & Belarus
Europe, Russia
Kurita Europe APW GmbH
Co., Ltd., No. 58 Dongsheng Road
Xinchengdong Development Zone,
Av. Alcalde Barnils, 64-68
Local 4, Planta 2ª Bloque B
Kurita Europe GmbH Sp. z o.o.
Oddzial w Polsce Complete and Innovative
Giulinistraße 2 Jiangyin City, Jiangsu, China E-08173 Sant Cugat del Vallés ul. Puławska 469
D-67065 Ludwigshafen
Phone: +49 621 5709 3273
Phone: +86 510 869 96 866
Fax: +86 510 869 96 199
Barcelona
Phone: +34 93 675 0345
PL-02-844 Warszawa
Phone: +48 22 395 64 00
Treatment for Reverse Osmosis
Fax: +49 621 5709 53273 Fax: +34 93 590 7393 Fax: +48 22 395 64 08

France, Luxembourg Italy Turkey & Middle East


and other Membrane Systems
Niederheider Str. 22, Y20
D-40589 Düsseldorf & North Africa Kurita Europe APW GmbH Kurita Turkey Kimya A.Ş.
Phone: +49 211 797 9190 Kurita France SAS Filiale Italia Tugayyolu cad. Ofisim İstanbul
Fax: +49 211 798 2262 53 Allée de l´Étang, Bât. A Via Monteverdi 11 Plazaları No:20 B Blok Kat 4
F-69670 Limonest I-20131 Milano Daire 23 Maltepe a
Phone: +33 478 43 42 50 Phone: +39 02 295 164 53 TR-İstanbul
www.kurita.eu Fax: +33 478 83 34 78 Fax: +39 02 294 082 59 Phone: +90 216 450 08 62
E-Mail: info@kurita.eu Fax: +90 216 450 09 34

Greece Sweden & Scandinavia


Kurita Europe APW GmbH Kurita Sverige AB
Georgiou Papandreou 82 Marieholmsgatan 56
GR-14452 Metamorfosi, Athens 415 02 Göteborg
Phone: +30 210 28 37 559 Phone: +46 31-725 34 60
Kurita Osmotech©

Fax: +30 210 28 37 601 Fax: +46 31-725 34 69

The information presented herein corresponds to our interpretation of certain test results and field experience to date. This information is not to be taken as warranty or representation
for which we assume legal responsibility. It is offered solely for your consideration, investigation and verification.
Complete and Innovative Treatment
for Reverse Osmosis and other Membrane Systems

Reverse osmosis (RO) has become a prime source of drinking water and make-up water for industrial Antiscalants
processes. Loss of performance of reverse osmosis membranes is mainly due to fouling, scaleforming Osmotech® prevents membrane fouling, reduces the »» Calcium and magnesium hardness deposits
salts and biological contamination, or the insufficient pretreatment of make-up water. frequency of cleaning and thus increases membrane »» Calcium phosphate and calcium fluoride
performance and lifetime. A full range of antiscalants is »» Calcium, barium and strontium sulphate
available with specific programs against precipitation of »» Iron oxide
various salts, e.g. based on: »» Silica and manganese
What is Fouling? What is Scaling?
Blocking of the membrane due to contamination by During the reverse osmosis process, a salt solution The essential properties of Osmotech® products are scale inhibition and hardness stabilization. In the sub-stoichiometric
any kind of particulate material is known as fouling. flows along a membrane and is concentrated to range, they show the so-called Threshold effect. Beyond the stabilisation limit a non-adherent amorphous crystal is
It can be caused by suspended colloidal particles a certain level. When the concentrations of the obtained so that they can be easily rejected from the membrane system by means of the brine flow and its “sweeping
or indeed, be a biological contamination on the dissolved salts exceed their solubility levels, the effect”. Furthermore, the dispersants delay the sedimentation of mineral sludge in RO systems.
surface of the membrane (bio-fouling). salts may precipitate. A crystalline layer is formed They transfer sludge deposits into the aqueous phase and
remove them from the system in the concentrate flow. val
which is known as scaling. IWA appro
with K
Products paration o
f
for the pre available
ater
drinking w
Cleaners
Discover the performance of Osmotech® formulated cleaners for your membrane systems.
As a very important step in maintenance programs, cleaning allows restoration of peak membrane performance.
Our full range of acid, alkali or enzyme based cleaners were tested in our membrane-dedicated laboratory for efficiency
and compatibility with main types of membranes. Applied according to customized procedures, they will remove all
possible contaminants that might be encountered.

Type of deposits or contamination Type of deposits or contamination

Inorganic Blends of inorganic and organic acids


Any kind of fouling is not desired, as it will imply With decades of experience in Water Treatment,
losing filtration performance and water quality, Kurita Europe APW combines innovative technologies Optimized combinations of complexants, alkali, caustic soda,
increase of operational costs and plant breakdown. and services. Thanks to our intensive research and Organic or colloidal fouling
potassium hydroxide, anionic and non-ionic detergents, phosphates
Most of the developments done nowadays development we can offer an extensive range of
in Desalination Engineering are dedicated to products. Specifically for membrane processes we Biological Alkaline and/or enzymatic cleaners

Operation Cost Reduction: development of Brine developed the product line Osmotech®.
Energy Recovery Systems and Energy effective
membrane and plant designs. It has been Osmotech® technologies prevent membrane
demonstrated that the presence of fouling and Pretreatment and Auxiliaries
fouling and scaling as well as clean the
deposits on the membranes has a strong negative membranes from all contaminants that might Biocides & Disinfectants Chlorine and Oxidizing Biocide Removers
impact on energy consumption. The application be encountered. Additional to the classical treatment with oxidizing Products to protect the membrane from the attack
and design of a correct water treatment program biocides, Kurita Europe APW has developed a full range of aggressive biocides
not only will reduce the plant operational costs, of environmental friendly non-oxidizing biocides which
but also will improve the performance of the plant Osmotech® helps you optimizing the efficiency allow a direct contact with the membrane for a better Flocculants & Coagulants
allowing high recovery rates, granting smooth of your membrane processes, achieving the disinfection and control of bacteria, fungi, and algae Products to achieve the best quality of make-up
operation, reducing the number of cleaning steps greatest economy and long-term operational growth in membrane systems. water for your membrane systems
and improving efficiency. reliability.
Attention: Use biocides safely. Always read label an product information before use.

You might also like