imaging
1
Product highlights Moor Instruments
Moor are proud to offer a choice of six Moor Instruments, established in The future
advanced imaging systems for assessment 1987, is a world leader in the design,
Our aim will always be to offer technical excellence
of microvascular blood flow. Featured manufacture and distribution of within each product we manufacture.
products include; monitoring and imaging systems to Our experienced and highly skilled design team are
assess blood flow and oxygen in the also involved with a number of development projects
• Clinical Burn Assessment for other partners and manufacturers. Whatever your
microvasculature.
A choice of two clinically proven needs, as a researcher, clinician or manufacturer,
systems with the release of the rapid Moor will work harder for you.
moorLDLS-BI. Customer support
First-hand experience of R&D within Moor dates back
• Laser Speckle - moorFLPI-2 to 1978. We have the expertise to help with your
Fast full-field imaging based on the application and the enthusiasm to help find answers
laser speckle technique - now with to your questions.
image resolution of 6.6M pixels/cm2 and
We give priority to performance, quality and service
full area imaging at 100 frames/sec. and strive to be our customers number one choice.
Whatever your needs, as a researcher, clinician or
• Laser Doppler - moorLDI2-HIR manufacturer, Moor will work harder for you.
fully optimised for hind limb ischemia
and angiogenesis modelling with 785nm
laser and focussed optics to enable clear
imaging of subsurface collateral vessels.
2
Choosing the right package
START HERE
Large area assessment
moorLDI2-BI SEE PAGE 4
Burn assessment systems
Clinical Burn Assessment approved for clinical diagnosis
or
Research
Rapid assessment
moorLDLS-BI SEE PAGE 5
Blood flow imaging with The only commercial imaging system to offer blood flow and
simultaneous oxygen oxygen assessments simultaneously
or moorO2Flo* SEE PAGE 6
without
High resolution, small area High resolution laser Doppler for pre-clinical
or imaging - best resolution of 100 microns per pixel
standard resolution,
moorLDI2-HIR SEE PAGE 8
medium to large area
3
moorLDI2-BI Large area burn assessment imager
Large area imaging is a key feature of the moorLDI2-BI.
Areas up to 50cm x 50cm can be mapped in one
scan (rather than a sequence that needs to be
Date Of Birth: 1 Jan 2001 (Age: 2) Time Post Burn: 58:56 hrs (Day 2 Post Burn)
“stitched”together), with scan times ranging from 40
Burn Cause: scald - water/drink Scan Size (WxH): 37.2 x 37.2 (cm x cm)
seconds up to 2 minutes.
All areas treated conservatively healed well by day 23 - as shown Key Features
in the photograph. The need for surgery of the upper left thigh was
indicated by the moorLDI2-BI. This was confirmed by biopsy, the
results of which showed full thickness burn within this area. • Scan times from 40 seconds
• Large assessment area of up to 50cm x 50cm
• Long reach mobile stand
LASER RADIATION
AVOID DIRECT EYE EXPOSURE
CLASS 3R LASER PRODUCT
WAVELENGTH 633nm MAX. POWER 2.5mW
IEC 60825-1:2014
4
moorLDLS-BI Rapid burn assessment imager
Rapid imaging is an essential feature of moorLDLS-BI
which is most useful when scanning patients who are
unable to keep still for long. With scan times of around 4
Date Of Birth: 1 Dec 2009 (Age: 11 months) Time Post Burn: 47:40 hrs (Day 1 Post Burn)
seconds for areas up to 15cm x 20cm the system is ideal
Burn Cause: contact - other Scan Size (WxH): 12.0 x 10.1 (cm x cm)
for paediatric cases and can also be used for adults with
easy to use repeat imaging to cover separate wounds or
adjacent areas of large burns.
Dorsum of hand - central area slightly deeper, the rest moorLDLS-BI with touchscreen panel PC and MS3b mobile stand
almost healed. Pink around edges. Surgery not performed.
Outcome Day 16
Key Features
Recorded as fully healed.
5
moorO2Flo High resolution blood flow and oxygenation imaging
The moorO2flo perfusion and oxygenation imager is the The software is user friendly and derived from our core
world’s first commercial imager to provide simultaneous imaging software environment , promoting smooth
blood flow and oxygenation change images. The workflow and advanced analysis functions.
imager combines laser speckle and RGB spectroscopic
techniques using a single video camera for simultaneously Because a dark environment is required for the
measurements. The blood flow image is similar to that Oxygenation images (Light frame tent included), the
provided by moorFLPI-2, whereas the oxygenation system is ideally suited to all animal models and human
images (oxygen haemoglobin and deoxygen haemoglobin research where the lighting can be effectively controlled.
concentration change) show changes from the initial
baseline rather than absolute values. The moorO2Flo is intended for use in research and
educational life science applications only. The moorO2Flo
is not intended to be used for medical diagnostic or
therapeutic purposes.
CLASS 1
LASER PRODUCT
6
moorFLPI-2 High resolution, video frame rate blood flow imaging
The moorFLPI-2 blood flow imager uses the laser speckle The system is ideally suited to any application where
contrast technique to deliver real-time, high-resolution rapid changes are occurring – where conventional laser
blood flow images, providing outstanding performance Doppler imaging could not provide data with sufficient
in a wide range of pre-clinical and clinical research time or spatial resolution. It is possible to image cardiac
applications, such as stroke modelling, spreading cortical pulsations, fast changes during reactive hyperaemia and
depression, inflammation and irritancy. spatial variations due to axon reflex and drug stimulations.
The moorFLPI-2 is ideal for very high resolution imaging,
User-friendly features promote smooth workflow and enable
visualising blood flow in structures as small as 3.9
the high through-put required to scan cohorts quickly and
microns.
accurately. Advanced analysis functions help you to draw
sound conclusions from your blood flow images.
Key Features
• Frame rates up to 100 images per second
• Motorised x10 optical zoom and auto focus
• Scan areas from 6mm x 8mm up to 225mm x 300mm
• Colour photo matches blood flow images precisely
Forearm blood flow flare response to intradermal • Best spatial resolution of 3.9um per pixel (6.6M
histamine. The images enable different areas to be
analysed with high spatial and temporal resolution.
pixels/cm2)
7
moorLDI2-HIR High resolution imager
The moorLDI2-HIR is suitable for a wide range of pre- The system is in routine use in numerous laboratories
clinical research investigations, more typically where and clinics globally and employs unique, optical design
smaller areas are under investigation. The system features and signal processing in order to generate the highest
unique focused optics to provide 50 micron pixel size and resolution and clearest images of its class. LDI is often
512 x 512 pixel resolution with version 6 software for high compared to laser speckle imaging and whilst there
resolution blood flow images. The scan areas range from are some similarities, both techniques offer unique
just 2.5cm x 2.5cm up to 25cm x 25cm with scan times advantages. LDI (and moorLDI2-HIR in particular)
typically less than 5 minutes. Use of 785nm wavelength generally offers deeper penetration enabling enhanced
laser provides a deeper measurement depth, optimal for visualisation of small vessels below the tissue surface,
angiogenesis studies such as hind limb ischemia and perfect for pre-clinical studies. For certain applications
tumour modelling and pre-clinical cerebral blood flow these features are critical.
imaging. Highly refined image measurement and analysis
software allows for flexibility in measurement set up and
comprehensive analysis functions. The moorLDI2-HIR
features a colour photo image of the scanned area and
automatic distance measurement, making the positioning
and comparison of images easier.
Angiogenesis modelling in hind limb ischemia
model, where average perfusion in a ligated limb is
compared with the control limb. Multiple scans over
days can identify the time course of collateral vessel
development.
Key Features
• High resolution – maximum resolution
of 41,600 pixels per cm2
• 2.5cm x 2.5cm scan area at maximum resolution
8
moorLDI2-IR Near Infra-Red imager
The moorLDI2 laser Doppler blood flow imager offers a A full range of accessories are available, including stands
well proven, high specification solution to your blood flow for clinical or bench top use. Dedicated software and
application for clinical or research application. The system hardware is available to enable control of iontophoresis,
is in routine use in numerous laboratories and clinics pressure and skin heating protocols (please refer to the
globally and employs unique, optical design and signal MIC2 brochure for iontophoresis control, moorVMS-PRES
processing in order to generate the highest resolution and brochure for pressure control and the moorVMS-HEAT
clearest images of its class. brochure for skin heating).
Images reproduced with kind permission of Dr Faisel Khan and Baseline (image 1), post cold water immersion (image 2),
Dr David Newton, Ninewells Hospital, Dundee. 7.5 minutes recovery (image 3) and 15 minutes recovery
(image 4).
Key Features
• Highest sensitivity of moorLDI2 range
• Suitable for wide range of research applications
• Maximum resolution of 2,600 pixels per cm2
• Scan areas from 5cm x 5cm to 50cm x 50cm
Pre-treatment 12 weeks post-treatment
9
Issue 9_1 - English
Summary chart Moor Instruments blood flow imaging product range
www.moorclinical.com www.moor.co.uk
PRODUCT
moorLDI2-BI moorLDLS-BI moorLDI2-IR moorLDI2-HIR moorFLPI-2 moorO2Flo*
Oxygen Imaging
SCAN AREA AT FULL 5x5 3.7 x 10 5x5 2.5 x 2.5 0.8 x 0.6 0.56 x 0.75
cm x cm
RESOLUTION to 50 x 50 to 20 x 15 to 50 x 50 to 5 x 5 to 30 x 22.5 to 15 x 20
MAXIMUM SCAN RESOLUTION Pixels 256 x 256 256 x 64 512 x 512 512 x 512 2064 x 1544 580 x 752
MAXIMUM PIXEL DENSITY Per cm2 2,600 440 2,600 41,600 6,600,000 1,038,476
MONITORING MODE Number of Points - - 1 point / 40Hz 1 point / 40Hz 16 R.O.I.s / 100Hz 16 R.O.I’s / 20Hz
Superficial/Nutritive
MEASUREMENT DEPTH
Superficial/ Full Skin Thickness
LASER CLASSIFICATION 3R 3R 3R 3R 1 1
10
Notes
11
innovation in microvascular assessment
Moor Instruments Ltd Millwey Axminster Devon EX13 5HU UK tel +44 (0)1297 35715 fax +44 (0)1297 35716 email sales@moor.co.uk
Please visit www.moor.co.uk for full details of our international distributors and partners