LEGEND :

SYMBOL DESCRIPTION

50W LED LIGHTS

This Site 3 GANG CONVENIENCE OUTLET

2 GANG CONVENIENCE OUTLET

1 GANG CONVENIENCE OUTLET

CIRCUIT RETURN

KILO WATT HOUR METER

PANEL BOARD

03 Location map CIRCUIT BREAKER

E01 SERVICE ENTRANCE


1 S1f
POWER CIRCUIT
S1f

LIGHTING CIRCUIT

S1 ONE SINGLE POLE SWITCHES

2 S2 TWO SINGLE POLE SWITCHES

S1b S1c
S3 THREE SINGLE POLE SWITCHES
S1c

GENERAL NOTES:
S1b
1. ALL ELECTRICAL WORKS SHALL BE DONE IN ACCORDANCE WITH THE

PROVISION OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL

CODE, THE LAWS AND THE ORDINANCES OF THE LOCAL ELECTRICAL CODE,

ENCODING AUTHORITIES ( P.E.C. ) AND THE OF THE UTILITY COMPANY.

2. ALL CONDUITS AND METAL FRAMES OF THE EQUIPMENT SHALL BE BONDED


S1d
S1d TOGETHER BY MEANS OF COPPER TRAPS.

3. ALL WIRING FOR TELEPHONE / INTERCOM SHALL BE RIGID PVC SCHED. 40

FOR RISER AND UNDER FLOOR CONDUIT RUNS. WIRING FOR THE FIRE

ALARMAND AUXILLIARIES SHALL BE IMC.

4. ALL WIRING FOR POWER & LIGHTING SHALL BE EMT FOR BRANCH CONDUIT

NOT LARGER THAN 25mm Ø AND LARGER SHALL BE IMC FOR FEEDERS AND
S1a
RISER. FLEXIBLE METAL CONDUIT ( FMC ) SHALL BE USE WHERE IMC AND

EMT IS EMPRACTICAL.

5. PROVIDE FULL BOXES WHENEVER NECESSARY ALTHOUGH NOT SHOWN ON

S1e PLANS PROVIDE G.I. WIRE ( GUIDE WIRE ) ON EMPTY CONDUITS FOR SPARE PROVISION.

S1e 6. NO BRANCH CIRCUIT SHALL HAVE A LOAD OF MORE THAN 80% OF ITS RATING.

7. VERIFY EXACT LOCATION OF MOTOR PUMP AND ACU MOTORS PRIOR TO INSTALLATION.
PB 8. VERIFY EXACT LOCATION OF POWER SERVICE PRIOR TO INSTALLATION.
PB
9. MOUNTING HEIGHTS SHALL BE AS PER PHILIPPINE ELECTRICAL CODE
S1a
( P.E.C. ) STANDARD. ALL ELECTRICAL EQUIPMENT AND DEVICES MOUNTING

HEIGHTS SHALL BE VERIFIED OR CONFIRMED TO THE SUPERVISING

Ground Floor Lighting Lay-out Ground Floor Power Lay-out ELECTRICAL ENGINEER OR ARCHITECT PRIOR TO INSTALLATION.

01 Electrical Lay-out Plan 02 Electrical Lay-out Plan 10. ALL ELECTRICAL WORKS HERE IN SHALL BE DONE UNDER THE DIRECT

SUPERVISION OF A REGISTERED ELECTRICAL ENGINEER OR MASTER ELECTRICIAN.


E01 Scale 1:60 E01 Scale 1:60
FROM THE OFFICE OF: S E A L PROJECT TITLE : APPROVED AS PER PLAN AND SPECIFICATIONS: SHEET CONTENT : DRAWING NO.
NO.

PRC REG. LIGHTING LAYOUT PLAN


VALIDITY PROPOSED ONE STOREY POWER LAYOUT PLAN
LEGEND
NO. RESIDENTIAL BUILDING MARIA CHRISTINE JUNIO GENERAL NOTES SHEET NO.
PTR DATE LOCATION MAP
O W N E R
PLACE
ELECTRICAL ENGINEER
TIN N0. LOCATION : BARANGAY CALIBUNAN , CABADBARAN CITY ADDRESS: BARANGAY CALIBUNAN , CABADBARAN CITY