SERVICE POLE

SCHEDULE OF LOADS ( PANEL BOARD )


AMPERE / PROTECTION / WIRE SIZE CONDUIT SIZE
CKT. QTY WATTS VOLTS
NO. LOAD DESCRIPTION CIRCUIT CIRCUIT MM² MM
SERVICE ENTRANCE
1 LIGHTING OUTLET 5 250 230 1.08 15 AT 2 - 2.0mm² 15 mm Ø

2 CONVENIENCE OUTLET 3 900 230 2.60 20 AT 2 - 3.5mm² 20 mm Ø


PANEL BOARD
5.0 3 SPARE

4 SPARE
2.0

KW-HR METER

TOTAL WATTS 1150


BUILDING FLOOR

GROUND

SERVICE POLE DET.


TO LIGHTING POLE
CEILING CEILING

2 - # 14mm² THW CU. WIRE INSIDE


25mm Ø RSC PIPE
25MM PVC PIPE TO PANEL
SERVICE
LOAD COMPUTATION :
SCH.40 EMBEDDED
ENTRANCE
2OMM PVC PIPE ON WALL M KWH
SWITCH METER WATTS AMP
SCH.40 EMBEDDED TOTAL COMPUTED LOAD = X 80% D.F.
ON WALL VOLT
SWITCH 1150
X 80% D.F.
230
LIGTHING OUTLET 1 15AT 20AT
2 CONVENIENCE OUTLET

UTILITY BOX CONVENIENCE OUTLET = 5.0 AMPS


1400MM

SPARE 3 4 SPARE

USE 2- # 14mm² THW CU. WIRE INSIDE 25mm Ø


300MM

300MM
BACK TO BACK RSC PIPE @ 60 AMP CIRCUIT BREAKER
UTILITY BOX
UTILITY BOX 2"X4" Riser Diagram
2"X4"

FLOOR FLOOR

CONV. & SWITCH DET.

FROM THE OFFICE OF: S E A L PROJECT TITLE : APPROVED AS PER PLAN AND SPECIFICATIONS: SHEET CONTENT : DRAWING NO.
NO.

PRC REG. SERVICE POLE DET.


VALIDITY PROPOSED ONE STOREY CONV. & SWITCH DET.
SCHEDULE OF LOADS
NO. RESIDENTIAL BUILDING JOEL A. MONDANO RISER DIAGRAM SHEET NO.
PTR DATE
O W N E R LOAD COMPUTATION
PLACE
ELECTRICAL ENGINEER
TIN N0. LOCATION : P-9 BARANGAY CALAMBA , CABADBARAN CITY ADDRESS: P-9 BARANGAY CALAMBA , CABADBARAN CITY