8400

GENERAL NOTES 3100


8400
5300
3100 5300

UP
PB-1

3500
T&B
1. 1

2
1
3

5000

6000
2
4
3

DN
5 17
2. 6 16
4

7 15
5 17 2
PB-2

lav
6 16
8 14
7 15

FD
9 13
8 14

2500
10 12

3. CARPORT 9 13

wc
11
10 12

11

5450 2950
4. 3 3
PB-2 PB-2

GROUND FLOOR 3200 2000 3200

5.
2 LIGHTING LINE LAYOUT
SCALE 1: 100 M.
E-1 SECOND FLOOR

6.
5 POWER LINE LAYOUT
SCALE 1: 100 M.
E-1
7.

8. PANEL LPP1
8400
CKT CIRCUIT BREAKER
LOAD DESCRIPTION VA VOLT AMP SIZES OF WIRES AND CONDUITS
3100 5300 NO. AT AF POLE KAIC
9. 1 5x100- PIN LIGHT 500 230 2.17 20 50 2 10 2-3.5mm2 THHN + 1-5.5mm2 TW (G) IN 20mm Ø Conduit
2 06 - CONVENIENCE OUTLET 1,080 230 4.70 20 50 2 10 2-3.5mm2 THHN + 1-5.5mm2 TW (G) IN 20mm Ø Conduit

TOTAL: 1,580 230 6.87 30 50 2 10

LEGENDS & SYMBOLS: IL= ((1,580 VA) /(230V )+(0.25x 20)) x 0.80 DF COMPUTATION:

3500
1
PB-2
Iamp = 5.496 A

1 USE: 60AT/100AF, 2-POLE, 10KAIC, 240V MCCB


I T = [ 6.87 A + (20 x 0.25) ] x 80%
2-14mm² THHN +1-8.ømm² TW (G) IN 25MM Ø RSC

6000
2
M 3

= 5.496 A

DN
4

CKT. NO.
5 17
FEEDER LINE:
PANEL

lav
6 16

7 15
USE 2 - 30 mm2 THHN COPPER WIRE

FD
8 14 1 - 8.0 mm2 TW ( GROUND )

2500
9 13
IN 32 mm Ø RSC

wc
10 12

11

PANEL LPP2
CKT CIRCUIT BREAKER
LOAD DESCRIPTION VA VOLT AMP SIZES OF WIRES AND CONDUITS
NO. AT AF POLE KAIC
3200 2000 3200 1 10x100- PIN LIGHT 1,000 230 4.35 20 50 2 10 2-3.5mm2 THHN + 1-5.5mm2 TW (G) IN 20mm Ø Conduit
2 12 - CONVENIENCE OUTLET 2,160 230 9.39 20 50 2 10 2-3.5mm2 THHN + 1-5.5mm2 TW (G) IN 20mm Ø Conduit
3 ACU 1.5 HP 4600 230 20 30 50 2 10 2-5.5mm2 THHN + 1-5.5mm2 TW (G) IN 20mm Ø Conduit
SECOND FLOOR

3 LIGHTING LINE LAYOUT IL= ((7,760 VA) /(230V )+(0.25x 20)) x 0.80 DF
TOTAL: 7,760 230 33.74 30 50 2 10

COMPUTATION:
SCALE 1: 100 M.
E-1 Iamp = 31.016 A
I T = [ 33.77 A + (20 x 0.25) ] x 80%
USE: 60AT/100AF, 2-POLE, 10KAIC, 240V MCCB
2-14mm² THHN +1-8.ømm² TW (G) IN 25MM Ø RSC
= 31.016 A
THIS SITE FEEDER:
IT= (5.496+31.016)+(0.25x20)x0.80DF= 33.21 A

FEEDER LINE:

8400 USE 2 - 30 mm2 THHN COPPER WIRE


1 - 8.0 mm2 TW ( GROUND )
3100 5300 IN 32 mm Ø RSC

M
MDP
UP

100AT, 2P
T&B
1

3
2-14mm2 THHN+1-8.0mm2
THHN (G) in 25mm DIA. RSC 2-14mm2 THHN+1-8.0mm2

5000
4

5 17
THHN (G) in 25mm DIA. RSC
6 16 PB1 PB2
7 15

8 14
60AT, 2P 60AT, 2P
9 13 1
PB-1
20AT, 2P 30AT, 2P 20AT, 2P 30AT, 2P
10 12

11 CARPORT
1 2 1 2
30AT, 2P
3

5450 2950
GROUND

GROUND FLOOR
GROUND

4 POWER LINE LAYOUT


1 VICINITY MAP E-1
SCALE 1: 100 M. 6 LOAD COMPUTATION & RISER DIAGRAM
SCALE NTS SCALE
E-1 E-1 NTS

ENGINEER CADD BY: DATE: PROJECT TITLE: OWNER: SHEET CONTENT: PROJECT NO:

CJGS
AS SHOWN
PROPOSED 2 STOREY RESIDENTIAL
SHEET NO:

PRC: PTR: LOCATION:


IAPOA: ISSUED ON: E-1
ISSUED AT: MAHOGANY STREET, RIZAL EXTENSION, BARRETTO, OLONGAPO CITY