Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

TIA Selection Tool

Release Notes V2023.11

Unrestricted | © Siemens 2023


Features
Only available in offline version
• Integrated drive dimensioning (see here)
• Control Panel Design - Electrical dimensioning of main circuits according to IEC and
UL (see here)

Offline and Cloud Version


• Connection to Siemens Product Configurator (SPC): Successor DT Configurator
• New TIA Software Configurator (MVP):
• Selection of WinCC V8.0 products
• SIMATIC Energy Mangement
• Optimizations in the display of limits for current consumption
• SITOP Power Supplies Selectivity modules: Consumer below 0.5 A can be
selectively protected now
• Industrial Communication - Industrial Wireless LAN: Update of direct selection with
Smart Filters and removal of system configurator

Unrestricted | © Siemens 2023


Product updates
New products and updates for …

Controllers and I/O systems


• Uniform sorting of the product catalog for S7-1500 and ET 200MP
• ET 200SP: new Open Controller and F-TM Drives

BRAUMAT
• Various product updates at BRAUMAT

Industrial communication
• New Switch: SCALANCE XF204G
• Update of accessories for the product family XF204-2BA

Industrial controls
• Various updates for monitoring relays and 3RV21

IPC
• Various updates
Unrestricted | © Siemens 2023
Features of the integrated drive dimensioning
New functionalities and products
• Integration of product line SINAMICS G220 with currently released devices
• Integration of product line SINAMICS S120 Chassis (air-/ liquid-cooled) and
Chassis-2 (air- cooled) (ALM, SLM, Motor Module) – available functionality
comparable to S120 Booksize implementation
• Improvement of current calculation for 1FN3 und 1FW6 motors
• Redesign of the selection of power connectors, cables and shield connection plates
for S120 Booksize Motor Modules to avoid wrong and superfluous products in the
order list
• Addition of 1PH8 synchronous motors in SH 180 + 225
• Configuration updates: Harmonization of firmware version selection
for G120D/G120C/ET200pro FC-2, 1FK2/1FT2
• Data updates: 1FL2, 1PH8, S210, 2KJ8, power cables
• Lots of other bug fixes, improvements and internal changes

Not supported
• Help system: There is no special help system provided
• Project import
Unrestricted | © Siemens 2023
Features of the integrated drive dimensioning
Known issues
• For S120 Chassis-2 and S120 Chassis liquid-cooled DC link fuses and pre-
charge contactor are missing
• For S120 Chassis/Chassis-2: IGBT derating and compatibility check for
MASTERDRIVES braking modules is not available
• The current calculation for permanent magnet synchronous motors in the field
weakening range (operation to the right of the voltage limit curve) delivers wrong
results in some special cases. Calculation model will be improved in the future
• 1FK2 with planetary gears - Filtering and sorting currently not according to the
system values
• 1FK2 motor at S120 AC/AC at 230V supply system, the 2CC cable connection
cannot be selected
• There are situations in which options that have already been configured cannot
be retained after changing a selected motor

Unrestricted | © Siemens 2023


Features of Control Panel Design
New functionalities

• Support of cable dimensioning for combinations with frequency converter and


drive systems for IEC circuits.
• New combination data for frequency converter and drive systems for IEC
circuits.
• Optimized configuration workflow for soft starter combinations for IEC circuits.
• Soft starter configuration for US circuits according to UL508A.
• Minor improvements and bug fixes.

ATTENTION:
Some features are Beta features and not fully tested. They can contain errors. A hint is shown in
the software when you calculate the first device or load feeder combination.

Unrestricted | © Siemens 2023


Features of Control Panel Design
Known issues

• Cable dimensioning for soft starter combinations is not available yet.


• In some cases, the start of EPLAN generation is not successful if one or more
combinations in the main circuit are not fully configured (shows a warning
symbol). In this case try to start the EPLAN generation again.
• Currently there are no soft starter combinations with 3TF contactors available.
• After loading a project which was saved with an older version of TIA Selection
Tool, some load feeders can become invalid and need to be recalculated.

Unrestricted | © Siemens 2023


Disclaimer
© Siemens 2023

Subject to changes and errors. The information given in this document


only contains general descriptions and/or performance features which
may not always specifically reflect those described, or which may
undergo modification in the course of further development of the
products. The requested performance features are binding only when
they are expressly agreed upon in the concluded contract.

All product designations may be trademarks or other rights of


Siemens AG, its affiliated companies or other companies whose use by
third parties for their own purposes could violate the rights of the
respective owner.

Unrestricted | © Siemens 2023

You might also like