Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

FUEL ANALYSIS REPORT

REPORT NO H170666349 REPORT DATE 06-Jun-2017


VESSEL MATSON ANCHORAGE CUSTOMER MATSON NAVIGATION
COMPANY
IMO NUMBER 8419142 ATTN MR. Darl Jenkins
*
CONFORMANCE
The fuel sample tested conforms to Table 2 of ISO 8217:2005 specifications for grade IFO 380 - RMG
380
ITEMS TO NOTE
No Alerts for this fuel. See points 4, 27

ENGINE FRIENDLINESS NUMBER (EFN) 61 (poor) 1 to 100 (good)

SAMPLE INFORMATION / BDN INFORMATION

Grade IFO380-RMG380 Ship Quantity 850.550 MT


Bunkered Port TACOMA, WA-UNITED Supplier Quantity 850.550 MT
STATES
Bunkered Date 02-Jun-2017 Seal Status Sealed
Lab Seal No. J045409 Marpol Seal No. J045408
Supplier PHILLIPS 66 Sent From TACOMA - UNITED STATES,
Barge Date Sample Sent 05-Jun-2017
Sample From MANIFOLD Date Sample Recd 06-Jun-2017

SPECIFIED PARAMETERS FOR IFO380-RMG380 & TEST RESULTS

# Parameters / Units Test Results Specification Supplier Data


Limits
1 Density @15°C kg/m³ 987.1 Max 991.0 990.3
2 Viscosity @50°C cSt 328.0 Max 380.0 328.2
3 Flash Point °C > 70 Min 60.0
4 Upper Pour Point °C 12 Max 30.0
5 Micro Carbon Residue % (m/m) 13.55 Max 18.00
6 Ash % (m/m) 0.025 Max 0.150
7 Water % (v/v) 0.10 Max 0.50 -
8 Sulfur % (m/m) 1.85 Max 3.50 1.8500
9 Vanadium mg/kg 51 Max 300
10 Total Sediment Potential% (m/m) 0.01 Max 0.10
11 Al + Si mg/kg 30 Max 80

USED LUBRICATING OIL (ULO)

12 Zinc mg/kg <1 15


13 Phosphorus mg/kg <1 15
14 Calcium mg/kg 2 30

VISWA LAB HOUSTON: 12140 Almeda Road, Houston, TX 77045 Tel 1-(713)-842-1985 Fax 1-(713)-842-1981 Page 1 of 3
FUEL ANALYSIS REPORT

ADDITIONAL PARAMETERS

# Parameters / Units Test Results


15 Viscosity @100°C cSt 32.0
16 API Gravity 11.77
17 Aluminum mg/kg 13
18 Silicon mg/kg 17
19 Sodium mg/kg 17
20 Iron mg/kg 16
21 Lead mg/kg <1
22 Nickel mg/kg 19
23 Magnesium mg/kg <1
24 Potassium mg/kg <1

CALCULATED VALUES

# Parameters Values
25 Net Specific Energy MJ/kg 40.61
26 Gross Specific Energy MJ/kg 42.93
27 CCAI 849
28 Temperature for injection viscosity of 132
13 cSt °C
29 Minimum Transfer Temperature 41
30 Engine Friendlines Number 61

COMMENTS & SUGGESTIONS

Injection Viscosity (cSt) 8 10 11 12 13 15 18 20


Temperature for Injection (°C) 154.0 143.1 138.7 134.9 131.5 125.8 118.9 115.1

Density was confirmed by repeated analysis. Please note that the bunker density is higher than the lab measured
density.

VISWA LAB HOUSTON: 12140 Almeda Road, Houston, TX 77045 Tel 1-(713)-842-1985 Fax 1-(713)-842-1981 Page 2 of 3
FUEL ANALYSIS REPORT

SUGGESTIONS AND RECOMMENDATIONS TO SHIP OWNERS / OPERATORS / TECHNICAL STAFF

CALCULATION OF QUANTITY SUPPLIED BASED ON LAB TESTS


Quantity supplied as per ship (MT) 850.550
Density as per BDN Kg/m³ 990.3
Density as per lab test Kg/m³ 987.1
Water as per lab test %(v/v) 0.10
Quantity shortage due to density (MT) 2.748
Quantity shortage due to water (MT) 0.851
Total Quantity Shortage (MT) 3.599

*Above figures do not account for ISO 4259 criteria given in ISO 8217 Annex F

4 Upper Pour Point


Observation:

Heat and store this fuel at 10°C above the measured pour point temperature.

27 CCAI
Observation: Ignition delay is indicated by CCAI greater than 840 for mediumspeed engines and greater than 870 for
lowspeed engines.
OVERALL QUALITY
Engine Friendliness Number (EFN) is a unique bench-mark of fuel quality evaluated by VISWA LAB from the point of
view of engine wear and tear resulting from the use of this fuel. Based on EFN, which is calculated from the analysis
results listed in this report, the quality of this fuel is good.
Over hundreds of thousands of samples tested, it has been noted that when EFN is greater than 60, there is generally
no fuel related problems and when EFN is below 40, problems can be expected. Please note that EFN calculation
does not take into account the presence of any contaminants in the fuel.
NOTE: The conformance of this fuel to the contracted specifications may have no relationship to the evaluation of this
fuel based on EFN.
On behalf of Viswa Lab

Signed:

Sasikala Ramaiyan S

###VLS J4bngMeugMSq2R8FOxJxm78UIBsjGRBI70/7YI8rxcg= VLS###

This report shall not be reproduced except in full, without the written approval of the laboratory.

All the test methods will be referenced/equivalent test methods specified in ISO 8217:2010.

Viswa Lab assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information

or advice in this document or however provided, unless that person has signed a contract with Viswa Lab for the provision of this information or

advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.

Viswa Lab Houston is an ISO/IEC 17025:2005 laboratory for testing accredited by Perry Johnson Laboratory Accreditation Inc, Accreditation #

59212

VISWA LAB HOUSTON: 12140 Almeda Road, Houston, TX 77045 Tel 1-(713)-842-1985 Fax 1-(713)-842-1981 Page 3 of 3

You might also like